PubMed Health⌕ Search

PubMed · 12774180

A refined method for creating saccular aneurysms in the rabbit.

Abstract

We describe a refined animal model of human intracerebral aneurysms for testing endovascular devices for interventional neuroradiological procedures. Saccular aneurysms resulting from a stump of the right common carotid artery (CCA) were created in 15 New Zealand White rabbits by intraluminal incubation of elastase that was applied to the CCA after distal ligation of the CCA and proximal occlusion of the vessel using a pliable balloon. Subsequently a microcatheter was advanced to a position cranial to the balloon and the elastase was infused under fluoroscopic guidance to avoid retrograde flow to the trachea via aberrant vessels. Contrast-enhanced (CE) MRA at 1.5 T and conventional digital subtraction angiography was performed to test for aneurysm size, morphology and neck anatomy. In all 15 animals aneurysms resulted from the stump of the right CCA, ranging in size from 2.0 to 9.9 mm (mean 6.3 mm) in craniocaudal direction, 1.0 to 5.5 mm (mean 3.8 mm) in mediolateral direction and 1.0 to 3.8 mm (mean 2.4 mm) in neck diameter. Aneurysm morphology could be adequately demonstrated using CE MRA. On histological evaluation a loss of the internal elastic lamina was noted. The described method represents an easy, reliable, and reproducible method of aneurysm creation in the rabbit in an area of high shear stress. These aneurysms can be used for testing new endovascular devices for embolization of intracranial aneurysms.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Timo Krings, Walter Möller-Hartmann, Franz-Josef Hans, Ruth Thiex, Anna Brunn, Kira Scherer, Alexander Meetz, Heiko Dreeskamp, Klaus-Peter Stein, Joachim M Gilsbach, Armin Thron. 2003-05-28. A refined method for creating saccular aneurysms in the rabbit.. https://doi.org/10.1007/s00234-003-0976-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Patient dose from 3D rotational neurovascular studies.

The use of image-guided interventional radiological techniques is increasing in prevalence and complexity. Imaging system developments have helped improve the information available to interventionalists to plan and guide procedures. Information on doses to patients resulting from alternative imaging techniques or protocols is useful for both the process of justifying particular procedures and in optimizing the resultant exposures. Such information is not always available, especially for new or developing imaging techniques. We have undertaken a study of doses to patients associated with two alternative imaging methods for pre-intervention assessment of intracranial aneurysms. In the first technique the aneurysm is assessed from a series of digital subtraction angiography (DSA) runs taken at different imaging projections. The second technique involved acquiring images from one single image run while the imaging system rotated 180 degrees around the patient's head. In this technique, the aneurysm was then evaluated from a 3D reconstruction of the projection images. Effective doses were calculated using a computer model to simulate the exposure geometry and parameters. The mean dose from the DSA protocol used at our centre was 3.4 mSv and from the 3D rotational angiography (RA) technique was 0.20 mSv.

Angiography, Digital Subtraction↗

Treatment of an Angio-Seal-related vascular complication using the SilverHawk plaque excision system: a case report.

The Angio-Seal is a user-friendly and safe arterial closure device increasingly used after percutaneous diagnostic and interventional procedures. Although it achieves rapid hemostasis and facilitates early patient mobilization, its use can be associated with vascular complications. A specific problem related to the device is protrusion of the collagen plug into the artery, causing either acute occlusion or symptomatic stenosis. When this occurs, treatment with balloon angioplasty alone is usually suboptimal, while stenting of the common femoral artery may be undesirable. In this report we describe a novel application of the SiverHawk plaque excision system to treat a highly eccentric stenosis at the site of a previously deployed Angio-Seal. Since the device allows preferential cutting in the direction of the lesion and collagen plug debulking, it may be ideally suited to treat this complication without the need for stenting of the common femoral artery.

Angiography, Digital Subtraction↗

Carotid artery fibromuscular dysplasia.

Extracranial carotid artery fibromuscular dysplasia (FMD) is a rare finding that is frequently incidental and asymptomatic. It usually occurs in middle-age women and is secondary to medial fibrodysplasia or, less commonly, intimal fibrodysplasia. The carotid artery may be elongated or kinked and associated aneurysms have been reported. Symptoms including transient ischemic attack or stroke are uncommon and are due to low flow or embolization of platelet aggregates. Digital subtraction angiography demonstrates high-grade stenosis with the characteristic "string of beads" pattern. Antiplatelet medication with sequential imaging is the accepted therapy for asymptomatic lesions. Graduated endoluminal dilation under direct vision should be reserved for patients with documented lateralizing symptoms.

Angiography, Digital Subtraction↗