An ultrasound research interface for a clinical system.

Under a contract with the National Cancer Institute, we have developed a research interface to an ultrasound system. This ultrasound research interface (URI) is an optional feature providing several basic capabilities not normally available on a clinical scanner. The URI can store high-quality beamformed radio-frequency data to file for off-line processing. Also, through an integrated user interface, the user is provided additional control over the B-mode receive aperture and color flow ensemble size. A third major capability is the ability to record and playback macro files. In this paper, we describe the URI and illustrate its use on three research examples: elastography, computed tomography, and spatial compounding.

Biomedical Research↗

Ultrasonic strain imaging and reconstructive elastography for biological tissue.

Mechanical properties of biological tissue represent important diagnostic information and are of histological and pathological relevance. In order to obtain non-invasively mechanical properties of tissue, we developed a real-time strain imaging system for clinical applications. The output data of this system also allow an inverse elastography approach leading to the spatial distribution of the relative elastic modulus of tissue. The internal displacement field of biological tissue is determined using the above mentioned strain imaging system by applying quasi-static compression to the considered tissue. Axial displacements are calculated by comparing echo signal sets obtained prior to and immediately following less than 0.1% compression, using the fast root seeking technique. Strain images representing mechanical tissue properties in a non-quantitative manner are displayed in real-time mode. For additional quantitative imaging, the stiffness distribution is calculated from the displacement field assuming the investigated material to be elastic, isotropic, and nearly incompressible. Different inverse problem approaches for calculating the shear modulus distribution using the internal displacement field have been implemented and compared. The results of an ongoing clinical study with more than 200 patients show, that our real-time strain imaging system is able to differentiate malignant and benign tissue areas in the prostate with a high degree of accuracy (sensitivity=76% and specificity=89%). The reconstruction approaches applied to the strain image data deliver quantitative tissue information and seem promising for an additional differential diagnosis of lesions in biological tissue. Our real-time system has the potential of improving diagnosis of prostate and breast cancer.

Algorithms↗

Schlieren visualization of ultrasonic wave fields with high spatial resolution.

The visualization of ultrasonic wave fields in optically transparent liquids using the acousto-optic interaction is a well proven tool for the experimental investigation of wave propagation including wave field interaction effects with certain discontinuities and obstacles like reflection, refraction, and diffraction effects as well as for transducer testing and design. For high resolution visualization of wave fields including pulsed waveforms, pulsed light sources and sensitive optical imaging sensors with certain specifications are needed. In this paper the technical requirements of optical and electronic components for high resolution visualization of ultrasound wave fields will be presented. Also, specifications and operation results of a new designed, inexpensive Schlieren optical system will be presented, which is capable of pulsed wave field visualization in the MHz frequency range. The spatial resolution is high enough, not only for accurate beam shape and wave pattern visualization, but also for a gray-scaled display of wave amplitudes including amplitude zero crossings in ultrasound pulses. Consequently, ultrasonic wavelengths can be visualized quantitatively as well as wavelength changes of the ultrasound pulses while traveling through transparent media with different sound velocities. Results to be presented will include 2 MHz and 10 MHz experiments using single transducers as well as linear arrays of commercial medical scanners during their standard operation showing the system beamforming characteristics.

Journal Article↗

Contour tracking of specularly reflecting surfaces.

The aim of the presented work is to develop an ultrasonic imaging system for contour detection of specularly reflecting sheet metal surfaces and surface contour tracking during a continuous hydroforming process. Based on certain design considerations in context with hardware limitations to obtain on-line information about the state of forming during the whole process a sparsely filled ultrasonic 1D transducer array has been used with a limited number of transducer elements, operating at 2 MHz. It has been shown before, that "2.5D-geometries" (surface areas with curvatures independent of one direction) could be detected and tracked with a sufficient accuracy (linear aperture, 10 cm width, 21 transducers, error in sound propagation direction less than 1 mm). We now present the design and results of an imaging system for automated detecting and consecutive tracking of sheet metal surface contours during the forming process by means of an active contour model. To achieve a sufficient accuracy, a priori in process information, e.g., starting and final positions of the sheet metal, forming velocity, preceding instantaneous contour geometries are incorporated into the active model.

Journal Article↗

An ultrasound research interface for a clinical system.

Under a contract with the National Cancer Institute, we have developed a research interface to an ultrasound system. This ultrasound research interface (URI) is an optional feature providing several basic capabilities not normally available on a clinical scanner. The URI can store high-quality beamformed radio-frequency data to file for off-line processing. Also, through an integrated user interface, the user is provided additional control over the B-mode receive aperture and color flow ensemble size. A third major capability is the ability to record and playback macro files. In this paper, we describe the URI and illustrate its use on three research examples: elastography, computed tomography, and spatial compounding.

Biomedical Research↗

Investigation of the influence of blood flow rate on large vessel cooling in hepatic radiofrequency ablation.

Radiofrequency (RF) ablation using high-frequency current has become an important treatment method for patients with non-resectable liver tumors. Tumor recurrence is associated with tissue cooling in the proximity of large blood vessels. This study investigated the influence of blood flow rate on tissue temperature and lesion size during monopolar RF ablation at a distance of 10 mm from single 4- and 6-mm vessels using two different approaches: 1) an ex vivo blood perfusion circuit including an artificial vessel inserted into porcine liver tissue was developed; and 2) a finite element method (FEM) model was created using a novel simplified modeling technique for large blood vessels. Blood temperatures at the inflow/outflow of the vessel and tissue temperatures at 10 and 20 mm from the electrode tip were measured in the ex vivo set-up. Tissue temperature, blood temperature and lesion size were analyzed under physiological, increased and reduced blood-flow conditions. The results show that changes in blood flow rate in large vessels do not significantly affect tissue temperature and lesion size far away from the vessel. Monopolar ablation could not produce lesions surrounding the vessel due to the strong heat-sink effect. Simulated tissue temperatures correlated well with ex vivo measurements, supporting the FEM model.

Animals↗

Sonohistology for the computerized differentiation of parotid gland tumors.

A system for the computerized differentiation of parotid gland tumors is proposed. The parotid gland is the largest of the salivary glands. It is found in the subcutaneous tissue of the face, overlying the mandibular ramus and anterior and inferior to the external ear. The classification system is based on a multifeature tissue characterization approach, using fuzzy inference systems as higher-order classifiers. Baseband ultrasonic echo data were acquired during conventional ultrasound imaging examinations using standard ultrasound equipment. Several tissue-describing parameters were calculated within numerous small regions of interest to evaluate spectral and textural tissue properties. The parameters were processed by an adaptive network-based fuzzy inference system, using the results of conventional histology after parotidectomy as the "gold standard." The results of the classification are presented as a numerical score indicating the probability of a certain tumor or alteration for each parotid gland. The score can be presented to the physician during examination of the patient to improve the differentiation between various types of parotid gland tumors. The system was evaluated on n = 23 cases of patients undergoing radical parotidectomy. The receiver operating characteristic curve area is A(ROC) = 0.95 +/- 0.07 when using fourfold cross-validation over cases and differentiating between various benign parotid gland tumors and monomorphic adenoma.

Adenoma↗

Initial experiences with real-time elastography guided biopsies of the prostate.

PURPOSE: Based on our first experiences with real-time elastography in the field of prostate diagnostics we evaluate its usefulness for biopsy guidance for prostate cancer detection. MATERIALS AND METHODS: After imaging with conventional B-mode ultrasound in conjunction with real-time elastography 404 men underwent systematic sextant biopsy. RESULTS: Overall prostate cancer was found in 151 of 404 cases (37.4%). In 127 of 151 cases (84.1%), prostate cancer was detected using real-time elastography as an additional diagnostic feature. CONCLUSIONS: The results show that it is possible to detect prostate cancer with a high degree of sensitivity using real-time elastography in conjunction with conventional diagnostic methods for guided prostate biopsies.

Aged↗

Development and evaluation of a high-frequency ultrasound-based system for in vivo strain imaging of the skin.

The elastic properties of skin are of great interest in dermatology because they are affected by many pathological conditions. In this paper, a technique for in vivo mechanical strain imaging of the skin based on high-frequency ultrasound (HFUS) is presented. Elastic skin properties are assessed applying suction to the skin surface with a stepwise increased vacuum and estimating the resulting displacements in a spatially resolved manner. Acquired radio frequency (RF) echo signals and their envelope are analyzed for this purpose. A computer-controlled vacuum system with a digital pressure control loop was developed for precise and reproducible deformation. In a first processing step, the skin surface is segmented. Local axial strains inside the skin are estimated from axial displacements, which are estimated from consecutive echo signal frames analyzing the phase of the complex cross correlation function of analytical echo signals. Furthermore, speckle tracking is applied to estimate axial and lateral displacements and to quantify axial and lateral strains. The correlation coefficient of windowed echo signals compensated for displacements are used as a measure to validate the estimated strains, which is essential to accomplish reliable in vivo measurements. Phantom experiments were performed to validate the proposed technique. Results of in vivo measurements are presented, showing the potential for mechanical strain imaging in the skin in vivo.

Burns↗

Ultrasound elastography for the age determination of venous thrombi. Evaluation in an animal model of venous thrombosis.

The exact age determination of venous thrombi is important if thrombolytic therapy or surgical thrombectomy is considered. Clinical symptoms as well as duplex-ultrasound and phlebography are unreliable in this respect and do not allow an exact age estimation. Ultrasound elastography can provide information about the elastic properties of thrombi. Since thrombus elasticity decreases with age due to the organisation process, it should be possible to use elastography to stage the degree of organisation and thereby determine the age of venous thrombi. Experimental venous thrombi aging 1, 3, 6, 9, 12 and 15 days were created in a porcine model by laparoscopic ligation of the infrarenal Vena cava in combination with transfemoral infusion of thrombin. The thrombosed iliac veins were explanted and embedded in gelatine, after that they underwent examination by ultrasound elastography. In addition, histological evaluation of the thrombi was performed. Elastography demonstrated a decline in thrombus elasticity between days 6 and 12 with the 12-day-old thrombi being about 3 times harder then the 6-day-old thrombi. This correlated with the histological findings, which demonstrated a marked increase in fibroblast and collagen production in the clots during this time, with the 12- and 15-day thrombi showing signs of advanced organisation. In conclusion, in an experimental setting, ultrasound elastography was helpful in determining the exact age of venous thrombi. The differences in elasticity were most pronounced between days 6 and 12, which is also the most relevant time frame when considering invasive therapies in human venous thrombosis.

Animals↗

A tutorial on the use of ROC analysis for computer-aided diagnostic systems.

The application of the receiver operating characteristic (ROC) curve for computer-aided diagnostic systems is reviewed. A statistical framework is presented and different methods of evaluating the classification performance of computer-aided diagnostic systems, and, in particular, systems for ultrasonic tissue characterization, are derived. Most classifiers that are used today are dependent on a separation threshold, which can be chosen freely in many cases. The separation threshold separates the range of output values of the classification system into different target groups, thus conducting the actual classification process. In the first part of this paper, threshold specific performance measures, e.g., sensitivity and specificity, are presented. In the second part, a threshold-independent performance measure, the area under the ROC curve, is reviewed. Only the use of separation threshold-independent performance measures provides classification results that are overall representative for computer-aided diagnostic systems. The following text was motivated by the lack of a complete and definite discussion of the underlying subject in available textbooks, references and publications. Most manuscripts published so far address the theme of performance evaluation using ROC analysis in a manner too general to be practical for everyday use in the development of computer-aided diagnostic systems. Nowadays, the user of computer-aided diagnostic systems typically handles huge amounts of numerical data, not always distributed normally. Many assumptions made in more or less theoretical works on ROC analysis are no longer valid for real-life data. The paper aims at closing the gap between theoretical works and real-life data. The review provides the interested scientist with information needed to conduct ROC analysis and to integrate algorithms performing ROC analysis into classification systems while understanding the basic principles of classification.

Diagnosis, Computer-Assisted↗

Vibrography during tumor neurosurgery.

OBJECTIVE: The aim of this study was to determine whether elastography, a sonographically based real-time strain imaging method for registering the elastic properties of tissue, can be used in brain tumor surgery. METHODS: A modification of classic elastography called vibrography was applied in these measurements with static compression replaced by low-frequency axial vibration. Twenty patients were examined with this technique during brain tumor surgery. A conventional sonographic system with a custom-designed radio frequency (RF) interface was used. The RF data were digitized with a 50-MHz, 12-bit peripheral component interconnect analog/digital converter for real-time or offline processing. Sonographic RF data were acquired with a 6.5-MHz endocavity curved array. A special applicator equipped with a stepping motor moved the ultrasonic probe and produced a low-frequency mechanical vibration of approximately 5 to 10 Hz with a vibration amplitude of 0.3 mm. RESULTS: Detection of tumors was possible in 18 of 20 cases. Brain tissue was normally color coded orange or red. Three major groups of tumors with different elastic properties relative to brain tissue could be differentiated. In 3 cases, the stiffness of the tumor was identical to that of brain tissue, but the tumors were surrounded by a thin yellow border. Six tumors displayed higher strain than brain, whereas 7 tumors exhibited lower strain than the surrounding cerebrum. Two patients could not be assigned clearly to either of these groups. CONCLUSIONS: These findings indicate that vibrography is a feasible imaging method for brain tumor surgery and may have numerous potential applications in neurosurgery if further improvements are made.

Adult↗

Ultrasonic imaging of sheet metal forming.

With sheet metal hydroforming, a sheet metal is formed by a liquid medium under high pressure (up to 1000 bar) and a cavity contour (die). As the exact state of forming is of interest, an ultrasonic imaging system is under development. The task is to determine the geometry of a sheet metal contour with respect to the original (before forming) and the final (die) state of the sheet metal. For this purpose, two different contour reconstruction algorithms were designed, tested and compared. With the reconstruction results it will be possible to determine the optimal distribution of transmitters and receivers in the ultrasonic transducer matrix. Experiments were conducted with one pair of transducers (unfocussed, center frequency 2 MHz) and a three axis stepper motor set-up. For each experimental set of data, the contour was reconstructed with both SAFT reconstruction algorithms. Both algorithms incorporate a priori information such as original and final contour and maximal axial dislocation of the sheet metal. The results for both algorithms are compared and the relative mean error in axial direction is 0.30% and 0.48%.

Journal Article↗

Ultrasonic multifeature tissue characterization for prostate diagnostics.

A new system for prostate diagnostics based on multifeature tissue characterization is proposed. Radiofrequency (RF) ultrasonic echo data are acquired during the standard transrectal ultrasound (US) imaging examination. Nine spectral, texture, first order and morphologic parameters are calculated and fed into two adaptive neuro-fuzzy inference systems (FIS) working in parallel. The outputs of the FISs are fed into a postprocessing procedure evaluating contextual information before being combined to form a malignancy map in which areas of high cancer probability are marked in red. The malignancy map is presented to the physician during the examination to improve the early detection of prostate cancer. The system has been evaluated on 100 patients undergoing radical prostatectomy. The ROC curve area using leave-one-out cross-validation over patients is A(Z) = 0.86 when distinguishing between hyperechoic and hypoechoic tumors and normal tissue and A(Z) = 0.84 when distinguishing between isoechoic tumors and healthy tissue, respectively. Tumors that are not visible in the conventional B-mode image can be located. Diagnosis of the prostate carcinoma using multifeature tissue characterization in combination with US imaging allows the detection of tumors at an early stage. Also, biopsy guidance and therapy planning can be improved.

Aged↗

Parameters of cerebral perfusion in phase-inversion harmonic imaging (PIHI) ultrasound examinations.

The aim was to evaluate phase-inversion harmonic imaging (PIHI) with respect to brain perfusion imaging using a novel "bilateral approach" (depth of examination: 150 mm) and established unilateral approach (100 mm). After bolus injection of two contrast agents (CA, Optison and SonoVue), perfusion-related parameters (time-to-peak intensity, Itpk, peak intensity, Ipk, and peak width, Wpk) were extracted by fitting a model function to time-intensity curves for different regions-of-interest (ROI) in 14 volunteers. In 207 (92%) of 224 ipsilateral ROIs and in 165 (98%) of 168 contralateral ROIs (372 or 95% of 392 altogether), parameters could be derived. Itpk and Wpk of gray matter ROIs did not vary in or between both CA groups (18.1-21.9 s and 7.9-14.2 s). ROIs within arteries showed significantly shorter Itpk (16.1-16.7 s) and longer Wpk (12.8-28.3 s). Level of significance was 0.05 (two-sided). Newer CAs are usable for nonlinear imaging over a wider range of acoustic intensities, so that sensitivity of PIHI is sufficient to image the brain bilaterally. This approach proves to be reliable in patients with adequate bone windows. For acute stroke patients, this implies that both hemispheres can be compared in one instead of two examinations, reducing time of examination by 50%. Furthermore, evaluation of regions close to the probe becomes possible. Thus, the "bilateral approach" should be considered as a new standard approach of acute ultrasonic perfusion imaging.

Adult↗

Contrast burst depletion imaging (CODIM): a new imaging procedure and analysis method for semiquantitative ultrasonic perfusion imaging.

BACKGROUND AND PURPOSE: Established methods of ultrasonic perfusion imaging using a bolus application of echo contrast agent provide only qualitative data because of various physical phenomena. This study was intended to investigate whether a new ultrasound perfusion imaging method termed contrast burst depletion imaging (CODIM) may provide semiquantitative measures of parenchymal perfusion independent of examination depth and acoustic energy distribution. METHODS: In a system with a constant concentration of contrast agent, analyzing the decrease in image intensity that occurs with microbubble-destructive imaging modes yields parameters that are considered to correlate with tissue perfusion. This method was first evaluated with a perfusion model that showed that the main resulting parameter "perfusion coefficient" (PC) is a monotonic nonlinear function of flow velocity. Seventeen human volunteers were then scanned according to this method with the use of 2 different contrast agents. Results were correlated with those from perfusion-weighted MRI examinations. RESULTS: The PC did not show significant differences in gray matter areas (ranging from 1.466x10(-2) x s(-1) to 1.641x10(-2) x s(-1)) of the brain despite different insonation depths (eg, ipsilateral and contralateral thalamus). In contrast, white matter exhibited significantly lower perfusion values in both imaging modes (PC: 0.604x10(-2) x s(-1) to 0.745x10(-2) x s(-1); P<0.05). CONCLUSIONS: CODIM is a promising new tool of imaging parenchymal (brain) perfusion in healthy persons. The method provides semiquantitative and depth-independent perfusion parameters and in this way overcomes the limitations of the perfusion methods using a bolus kinetic. Further investigations must be done to evaluate the potential of the method in patients with perfusion deficits.

Adult↗

Technologies for haptic systems in telemedicine.

The ability to image the elastic properties of tissue is potentially useful in a variety of applications. The field of elastic imaging has grown in response to the potential use of such information in medical diagnosis. Real time ultrasound elastography represents a recent development in determining strain and elasticity distributions. Nevertheless, commonly used imaging techniques rely on the interpretation of two dimensional visual data displayed on a video screen. In reality however, physicians often prefer tactile exploration making the simultaneous portrayal of both video and haptic information most desirable. Since the 1970's many alphanumeric to tactile data conversion methods have been investigated, mainly with the ultimate aim of assisting the blind. More recently, interest has been directed toward the display of pictures on haptically explorable surfaces--Tactile imaging. Such a system would allow surgeons to examine hard sectors contained within soft tissue, and thereby assist in operations held remotely. The expansion of ultrasound elastography to 3D formats would mean the ability to haptically explore regions of the body normally inaccessible to human hands. For three-dimensional imaging the acquisition of sequential tomographic slices using Elastography, combined with image segmentation, enables the reconstruction, quantification and visualisation of tumour volumes. In a collaborative project between four research institutes, the aim is to produce a prototype three dimensional tactile displays comprising electrically switchable micromachined cells, whose mechanical moduli are governed by phase changes experienced by electrorheological and/or magnetorheological fluids. This will be integrated with a sensory ultrasonic elastography in order to present the human fingers with controllable surfaces capable of emulating biological tissue, muscle and bone.

Computer Simulation↗