PubMed Health⌕ Search

PubMed · 16550707

A tutorial on the use of ROC analysis for computer-aided diagnostic systems.

Abstract

The application of the receiver operating characteristic (ROC) curve for computer-aided diagnostic systems is reviewed. A statistical framework is presented and different methods of evaluating the classification performance of computer-aided diagnostic systems, and, in particular, systems for ultrasonic tissue characterization, are derived. Most classifiers that are used today are dependent on a separation threshold, which can be chosen freely in many cases. The separation threshold separates the range of output values of the classification system into different target groups, thus conducting the actual classification process. In the first part of this paper, threshold specific performance measures, e.g., sensitivity and specificity, are presented. In the second part, a threshold-independent performance measure, the area under the ROC curve, is reviewed. Only the use of separation threshold-independent performance measures provides classification results that are overall representative for computer-aided diagnostic systems. The following text was motivated by the lack of a complete and definite discussion of the underlying subject in available textbooks, references and publications. Most manuscripts published so far address the theme of performance evaluation using ROC analysis in a manner too general to be practical for everyday use in the development of computer-aided diagnostic systems. Nowadays, the user of computer-aided diagnostic systems typically handles huge amounts of numerical data, not always distributed normally. Many assumptions made in more or less theoretical works on ROC analysis are no longer valid for real-life data. The paper aims at closing the gap between theoretical works and real-life data. The review provides the interested scientist with information needed to conduct ROC analysis and to integrate algorithms performing ROC analysis into classification systems while understanding the basic principles of classification.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ulrich Scheipers, Christian Perrey, Stefan Siebers, Christian Hansen, Helmut Ermert. 2005. A tutorial on the use of ROC analysis for computer-aided diagnostic systems.. https://doi.org/10.1177/016173460502700304

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Use of a screening device for sleep apnea in clinical practice].

About 2-4% of adults suffer from obstructive sleep apnea (OSA), which is the most common sleep-related breathing disorder (SRBD). Repetitive obstructions of the upper airway mean that it is associated with hypertension and an elevated cardio- and cerebrovascular morbidity, which can be lowered by means of effective therapy. These patients cannot be treated correctly unless they are identified early in the course of the condition. Therefore, this study evaluated the use of the microMESAM screening device (known up to December 2005 as the "ApneaLink") in 61 patients in whom SRBD was suspected. The device proved reliable and practical in application.

Diagnosis, Computer-Assisted↗

Computer-aided diagnosis for improved detection of lung nodules by use of posterior-anterior and lateral chest radiographs.

RATIONALE AND OBJECTIVES: We developed a computerized scheme for detection of lung nodules in the lateral views of chest radiographs, in order to improve the overall performance in combination with the computer-aided diagnostic (CAD) scheme for posterior-anterior (PA) views. MATERIALS AND METHODS: We used 106 pairs of PA and lateral views of chest radiographs (122 lung nodules) for development of the CAD scheme. In the CAD scheme for lateral views, initial candidates of lung nodules were identified by use of a nodule enhancement filter based on the edge gradients. Thirty-four image features extracted from the original and the nodule-enhanced images were used for the rule-based scheme and for artificial neural networks (ANNs) for removal of some false-positive candidates. The computer performance was evaluated with a leave-one-case-out test method for ANNs. For PA views, we used the existing CAD scheme, which was trained with one-half of 924 chest images and then tested with the remaining images. RESULTS: When the CAD scheme was applied only to PA views, the sensitivity in the detection of lung nodules was 70.5%, with 4.9 false positives per image. Although the performance of the computerized scheme for lateral views was relatively low (60.7% sensitivity with 1.7 false positives per image), the overall sensitivity (86.9%) was improved (6.6 false positives per two views), because 20 (16.4%) of the 122 nodules were detected only on lateral views. CONCLUSIONS: The CAD scheme by use of lateral-view images has the potential to improve the overall performance for detection of lung nodules on chest radiographs when combined with a conventional CAD scheme for standard PA views.

Diagnosis, Computer-Assisted↗

Improvement of the detection of myocardial ischemia thanks to information technologies.

BACKGROUND: The standard 12-lead ECG remains one of the basic investigations for the early detection and assessment of acute coronary syndromes. It is easy to perform, anywhere and anytime, and can be digitally transmitted within minutes to an emergency medical service for remote advice and triage. But the conventional ST-segment deviation criteria are of limited diagnostic accuracy. The purpose of this study is to investigate how much the use of computerized ECG techniques based on the measurement of the serial spatiotemporal ECG changes could improve the detection accuracy of transmural myocardial ischemia. METHODS: We considered the serial changes of continuous 12-lead ECGs of 90 patients undergoing elective percutaneous coronary angioplasty (PTCA) recorded during balloon inflation as an experimental model of ECG changes induced by coronary artery occlusion. The spatiotemporal ECG changes were measured according to the CAVIAR method and assessed by multivariate discriminant analysis in reference to serial changes of control recordings and standard ECG criteria. RESULTS: The diagnostic accuracy of the CAVIAR criteria for ischemia detection was 97%, with sensitivity of 98% and specificity of 96%, whereas the diagnostic accuracy of the conventional ST-segment criteria was 74%, with sensitivity of 60% and specificity of 88%. The increase of overall performance was obtained for all the occlusion locations. CONCLUSIONS: Computer-assisted quantitative serial ECG analysis, taking into account the spatiotemporal changes of the QRS and T waves, would provide the physician with additional information for significantly improving the detection of transmural myocardial ischemia.

Diagnosis, Computer-Assisted↗