Henry M Spotnitz

Publications and source records attributed to Henry M Spotnitz.

At least 19 recordsLinked to original sources

Ventricular diastolic stiffness predicts perioperative morbidity and duration of pleural effusions after the Fontan operation.

BACKGROUND: We validated the clinical relevance of ventricular stiffness by examining surgical morbidity in children with univentricular hearts undergoing Fontan operation. We hypothesized that ventricular stiffness affects Fontan morbidity, particularly duration of pleural effusions. METHODS AND RESULTS: Sixteen children with right ventricular (RV) (n =11) or left ventricular (LV) (n =5) dominance were studied intraoperatively at a median age of 3.3 years (1.8 to 5.1). Transesophageal long-axis echocardiograms and ventricular pressure by micromanometer provided end-diastolic pressure (P) area (A) relations during initiation and conclusion of cardiopulmonary bypass. Curve fitting to the equation P=alphae(betaA) defined the ventricular stiffness constant, beta. Changes in beta and clinical correlations were examined. Ventricular stiffness increased after bypass in patients with complete pre-bypass and post-bypass data (n =11, P=0.023, mixed models methodology). Pre-bypass beta correlated well with duration of chest tube (CT) drainage (r=0.90, n =16), net perioperative fluid balance (r=0.71, n=14), and length of stay (LOS) (r=0.81, n =16). CT duration and LOS also correlated significantly with post-bypass beta (r=0.77 for both, n=11), but insignificantly with preoperative catheterization pressures. CONCLUSIONS: Intraoperative beta predicts duration of CT drainage, net perioperative fluid balance, and LOS after the Fontan operation. These observations could improve risk stratification and clinical management of children at high-risk undergoing the Fontan operation.

Chest Tubes↗

Effects of sequential biventricular pacing during acute right ventricular pressure overload.

Temporary sequential biventricular pacing (BiVP) is a promising treatment for postoperative cardiac dysfunction, but the mechanism for improvement in right ventricular (RV) dysfunction is not understood. In the present study, cardiac output (CO) was optimized by sequential BiVP in six anesthetized, open-chest pigs during control and acute RV pressure overload (RVPO). Ventricular contractility was assessed by the maximum rate of increase of ventricular pressure (dP/dt(max)). Mechanical interventricular synchrony was measured by the area of the normalized RV-left ventricular (LV) pressure diagram (A(PP)). Positive A(PP) indicates RV pressure preceding LV pressure, whereas zero indicates complete synchrony. In the control state, CO was maximized with nearly simultaneous stimulation of the RV and LV, which increased RV (P = 0.006) and LV dP/dt(max) (P = 0.002). During RVPO, CO was maximized with RV-first pacing, which increased RV dP/dt(max) (P = 0.007), but did not affect LV dP/dt(max), and decreased the left-to-right, end-diastolic pressure gradient (P = 0.023). Percent increase of RV dP/dt(max) was greater than LV dP/dt(max) (P = 0.014). There were no increases in end-diastolic pressure to account for increases in dP/dt(max). In control and RVPO, RV dP/dt(max) was linearly related to A(PP) (r = 0.779, P < 0.001). The relation of CO to A(PP) was curvilinear, with a peak in CO with positive A(PP) in the control state (P = 0.004) and with A(PP) approaching zero during RVPO (P = 0.001). These observations imply that, in our model, BiVP optimization improves CO by augmenting RV contractility. This is mediated by changes in mechanical interventricular synchrony. Afterload increases during RVPO exaggerate this effect, making CO critically dependent on simultaneous pressure generation in the RV and LV, with support of RV contractility by transmission of LV pressure across the interventricular septum.

Animals↗

Left ventricular pacing site-timing optimization during biventricular pacing using a multi-electrode patch.

A 71-year-old man with class IV congestive heart failure and an infected pacemaker/implantable cardioverter defibrillator (ICD) underwent median sternotomy for removal of endocardial leads with a 15-mm vegetation. Cardiac output during biventricular pacing was optimized with an aortic flow probe, a multi-electrode left ventricular patch, and a randomized protocol assessing 54 combinations of pacing site and right ventricle-left ventricle delay. Results that were assessed with response surface methodology determined permanent epicardial lead position and timing. The difference between the best and worst site-timing combinations altered cardiac index by nearly 70%. This experience demonstrates potential importance of the epicardial approach to site-timing optimization for biventricular pacing.

Aged↗

Load dependence of cardiac output in biventricular pacing: left ventricular volume overload in pigs.

OBJECTIVE: Previous work from our laboratory has demonstrated that optimization of biventricular pacing is load dependent. Cardiac output was maximized with a ventricular-ventricular delay of +40 milliseconds (right ventricle-first pacing) during right ventricular pressure overload and with a ventricular-ventricular delay of -40 milliseconds (left ventricle-first pacing) during right ventricular volume overload. We hypothesized that a model of left ventricular volume overload would also have specific timing requirements during biventricular pacing for optimization of cardiac output. METHODS: After median sternotomy in 6 anesthetized pigs, complete heart block was induced by ethanol ablation. A conduit was grafted from the left ventricle to the left atrium to produce left ventricular volume overload. An ultrasonic flow probe was placed around the conduit to measure retrograde flow that averaged 50% of cardiac output. During epicardial atrial tracking DDD biventricular pacing, atrioventricular delay was varied between 60 and 270 milliseconds in 30-millisescond increments for 20-second intervals. After determination of optimum atrioventricular delay, ventricular-ventricular delay was varied in 20-millisecond increments from +80 to -80 milliseconds for 20-second intervals. RESULTS: Ventricular-ventricular delays had no significant effect on cardiac output with the graft clamped (control). With the graft unclamped, however, there was a statistically significant (P = .0001 by repeated-measures analysis of variance) trend toward higher cardiac output with right ventricle-first pacing. CONCLUSIONS: Right ventricle-first pacing in swine significantly increased cardiac output during acute left ventricular volume overload, but not during the control state. Understanding load-specific pacing requirements will facilitate the development of perioperative temporary biventricular pacing for acute heart failure.

Animals↗

Ethanol induction of complete heart block in swine.

OBJECTIVES: A method for the induction of complete heart block (CHB) by ethanol injection and its success rate in a pig model of acute right ventricular failure is reported. Additionally, a review of the literature for the induction of CHB in laboratory animals is detailed. The literature review was undertaken to both compare our rate of success with other methods and provide insight into our technique and refine its implementation. BACKGROUND: Animal models of CHB have facilitated the understanding of therapeutics for various cardiac pathologies in humans. In our laboratory, CHB in pigs is used for complete control of heart rhythm in studies of biventricular pacing. MATERIALS AND METHODS: Experiments carried out on pigs in our laboratory that required the induction of CHB were reviewed retrospectively. In addition, review of the literature for creating CHB in animals was undertaken. Our success rate was compared to that of other groups. RESULTS: Our success rate (93%) is similar to other models of CHB, in general, and to those models that used the injection of caustic substances with thoracotomy. CONCLUSIONS: Review of the literature indicates that our success rate is comparable to other groups and that, although many approaches have been described in both open- and closed-chest models, success is likely dependent on the practice and skill of the experimenter. In addition, review of the literature has afforded us new perspectives on the experimental induction of CHB.

Animals↗

Optimized biventricular pacing in atrioventricular block after cardiac surgery.

BACKGROUND: Temporary pacing is required after open-heart surgery for treatment of heart block. Atrioventricular delay and ventricular pacing site might be manipulated to increase cardiac output. We hypothesized that by optimizing both atrioventricular delay and ventricular pacing site a 10% improvement in cardiac output would be observed compared with a standard pacing protocol. METHODS: Seven patients in first or third degree heart block after valve replacement surgery had temporary wires sewn to the right atrium, right ventricle, and left ventricle. Cardiac output was measured by integrating flow velocity from an ultrasonic aortic flow probe. After optimization of atrioventricular delays during atrial synchronous right ventricular pacing, the effects of ventricular pacing site were tested at the optimum atrioventricular delay for 10-second intervals. RESULTS: Biventricular pacing was beneficial in all patients with a mean increase of 22% in cardiac index over right ventricular pacing (1.95 L/min/m2 +/- 0.27 standard error of the mean (SEM) to 2.38 L/min/m2 +/- 0.27 SEM, p = 0.0012) and 14% over left ventricular pacing (2.08 L/min/m2 +/- 0.22 SEM to 2.38 L/min/m2 +/- 0.27 SEM, p = 0.0133). Comparing optimized with standard pacing for 30-second intervals yielded a mean increase of 10% in cardiac index over three respiratory cycles (2.87 L/min/m2 +/- 0.33 SEM to 2.60 L/min/m2 +/- 0.37 SEM, p = 0.009) and 17% at the corresponding end-expiratory beats (2.76 L/min/m2 +/- 0.33 SEM to 2.36 L/min/m2 +/- 0.36 SEM, p = 0.011). CONCLUSIONS: Biventricular pacing at optimum atrioventricular delay improves cardiac output in patients with postoperative heart block by at least 10% compared with standard pacing.

Blood Pressure↗

Optimized perioperative biventricular pacing in setting of right heart failure.

AIMS: A 78-year-old female with prior atrioventricular junctional ablation for paroxysmal atrial fibrillation and implantation of DDDR pacemaker underwent repair of severe tricuspid insufficiency. Effects of biventricular pacing were tested with temporary wires at the conclusion of cardiopulmonary bypass. METHODS: An ultrasonic flow probe was placed on the ascending aorta for real time cardiac output measurements. Atrioventricular delay optimization was performed and biventricular pacing was initiated while right-left ventricular delays were varied. RESULTS: There was no advantage of biventricular pacing (optimum right-left ventricular delay of +80 ms) compared with existing DDD. CONCLUSIONS: This study confirms the physiological effects of right-left ventricular delay on cardiac output after cardiopulmonary bypass.

Aged↗

Na+/H+ exchange inhibition and antioxidants lack additive protective effects after reperfusion injury in the working heterotopic rat heart isograft.

BACKGROUND: The utility of combining strategies of myocardial protection was studied in intact rat hearts subjected to 1 hour of ischemia and 40 minutes blood reperfusion. METHODS: Lewis rats (n = 48) were divided into 4 transplant groups. Twenty-four hearts were arrested by coronary perfusion with hypothermic Celsior solution at 60 mm Hg. The aortic valve was punctured to introduce volume into the left ventricle (LV), and the hearts were abdominally isografted. Animals were either given both the antioxidant probucol (300 mg/kg) and the sodium-hydrogen exchange inhibitor cariporide (5 mg/kg) (CP; n = 6), just cariporide (CAR; n = 6), just probucol (PROB; n = 6), or neither drug (CON; n = 6). After 40 minutes of blood reperfusion, transplanted hearts were rearrested. The control recipients' native hearts (native; n = 6) were also arrested. Postmortem LV compliance relations and myocardial water content (MWC) were measured. RESULTS: Grafts protected by probucol were significantly more compliant than controls and significantly less compliant than grafts protected by cariporide alone and with both cariporide and probucol (p = 0.0001, analysis of variance). Compliance relations for CP overlapped those for CAR. All grafts were less compliant than natives. MWC was significantly greater in controls and PROB than in natives. CONCLUSIONS: Pretreatment with cariporide in the setting of ischemia-reperfusion injury provides greater protection against the development of diastolic abnormalities than probucol when Celsior solution is used for both arrest and preservation. In this model, there is no advantage to combining the drugs, supporting the hypothesis that there is an overlapping mechanism of protection.

Animals↗

Pacemaker lead thrombosis treated with atrial thrombectomy and biventricular pacemaker and defibrillator insertion.

Right atrial thrombosis and pulmonary embolism are infrequent complications of pacemaker insertion. We report a patient with a large mobile thrombus on an endocardial DDD pacing lead and probable pulmonary embolism. We believe that this is the first case of pacemaker lead thrombosis in which treatment included insertion of an epicardial biventricular pacemaker and an implantable cardioverter-defibrillator.

Angioplasty, Balloon, Coronary↗

Regional functional depression immediately after ventricular septal defect closure.

Left ventricular ejection is depressed immediately after repair of ventricular septal defect (VSD). Postrepair functional depression seen after VSD closure could result from a reduction in preload. However, other mechanisms could be at work. Functional depression could also be caused by closure of a low-impedance path for left ventricular ejection, the introduction of a stiff akinetic patch, or the operation itself. We reasoned that functional depression mediated by changes in preload or afterload should symmetrically affect end-diastole and end-systole, whereas depression resulting from changes in septal mechanics should be localized. We, therefore, performed segmental wall-motion analysis on intraoperative echocardiograms from patients undergoing VSD and atrial septal defect repair. After VSD closure, there was an asymmetric change in left ventricular end-systolic segment length and a decrease in fractional segment shortening localized to the septal and lateral walls, whereas patients with atrial septal defect had a symmetric increase in fractional shortening. These results suggest that acute functional depression after VSD repair is a result of localized impairment of septal function.

Cardiac Surgical Procedures↗

Load dependence of cardiac output in biventricular pacing: right ventricular volume overload in pigs.

BACKGROUND: Previous work from our laboratory has demonstrated that optimization of biventricular pacing is load dependent. During acute pulmonary stenosis and right ventricular pressure overload in swine, cardiac output was maximized by pacing the right ventricle 40 ms before the left ventricle. To extend those studies, this experiment examined biventricular pacing optimization during right ventricular volume overload. METHODS: After median sternotomy in 6 anesthetized domestic pigs, complete heart block was induced by ethanol ablation. A conduit was grafted from the right ventricle to the right atrium to simulate tricuspid insufficiency. During epicardial, atrial tracking DDD biventricular pacing, atrioventricular delay was varied between 60 and 180 ms in 30-ms increments. Right ventricular-left ventricular delay was varied at each atrioventricular delay from +80 ms (right ventricle first) to -80 ms (left ventricle first) in 20-ms increments. Aortic flow, right ventricular pressure, and electrocardiogram were measured at each pacemaker setting with the graft clamped and unclamped. RESULTS: Atrioventricular and right ventricular-left ventricular delays had no significant effect on cardiac output with the graft clamped. With the graft unclamped, however, there was a statistically significant (P =.003 by mixed modeling repeated measures analysis of variance) trend toward higher cardiac output with left ventricle-first pacing. CONCLUSION: Left ventricle-first biventricular pacing in swine significantly increased cardiac output during acute tricuspid insufficiency but not during the control state. Trials are warranted to develop clinical biventricular pacing for treatment of perioperative right ventricular dysfunction.

Animals↗

Echocardiographic analysis of ventricular geometry and function during repair of congenital septal defects.

BACKGROUND: This study investigated changes in left ventricular (LV) geometry and systolic function after corrective surgery for atrial (ASD) and ventricular septal defects (VSD). METHODS: Transesophageal LV short-axis echocardiograms were recorded before and after operative repair of ASD (n = 11) and VSD (n = 7). Preload was measured using LV end-diastolic area indexed for body surface area. Measurements of septal-freewall (D1) and anterior-posterior (D2) endocardial diameters were used to assess LV symmetry from D1/D2. Systolic indices included stroke area, area ejection fraction, and fractional shortening. RESULTS: Preload, stroke area, area ejection fraction, and fractional shortening of D1 increased after ASD repair but decreased after VSD repair (p < 0.05). End-diastolic symmetry increased after ASD closure and decreased after VSD closure (p < 0.05). Increases in stroke area and ejection fraction after ASD correction primarily reflected increased shortening of D1. A positive correlation was found overall between percent change in end-diastolic area (EDA) and percent change in area ejection fraction (r(2) = 0.80, p < 0.0001, n = 18). CONCLUSIONS: Preload was the primary determinant of changes in LV function in this series of ASD and VSD repairs. Intraoperative changes in position of the interventricular septum affected systolic and diastolic LV symmetry and septal free wall shortening. Additional studies are needed to define changes in afterload and contractility as well as diastolic compliance and systolic mechanics.

Child↗

Load dependence of cardiac output in biventricular pacing: right ventricular pressure overload in pigs.

BACKGROUND: The effect of biventricular pacing on stroke volume is believed to be dependent on right ventricular/left ventricular delay, but effects in individual patients are unpredictable. This variability may reflect relative right and left ventricular volume and/or pressure overloads. Accordingly, we tested the hypothesis that the relation of cardiac output to right ventricular/left ventricular delay is load dependent in a pig model of pulmonary stenosis. METHODS: After median sternotomy in 6 anesthetized, domestic pigs, complete heart block was induced by ethanol ablation. During epicardial, atrial tracking DDD biventricular pacing, atrioventricular delay was varied between 60 and 180 ms in 30-ms increments. Right ventricular/left ventricular delay was varied at each atrioventricular delay from +80 ms (right ventricle first) to -80 ms (left ventricle first) in 20-ms increments. Aortic flow, right ventricular pressure, peripheral arterial pressure, and electrocardiogram were measured in the control state and during pulmonary stenosis, created by tightening a snare around the pulmonary artery until cardiac output decreased by 50%. RESULTS: Atrioventricular and right ventricular/left ventricular delay had no effect on cardiac output during the control state, but during pulmonary stenosis there was a statistically significant (P =.0001, repeated-measures analysis of variance) right ventricular/left ventricular delay-related trend toward higher cardiac output with right ventricular pacing first. This effect was more pronounced when the optimal atrioventricular delay was determined first, resulting in a 20% increase in cardiac output when the optimal right ventricular/left ventricular delay was compared with simultaneous biventricular pacing. CONCLUSIONS: Optimized biventricular pacing in swine is associated with increased cardiac output during acute pulmonary stenosis, but not during the control state. Further studies are needed to determine whether specific types of right ventricular and left ventricular overload predictably affect the relation between right ventricular/left ventricular delay and cardiac output.

Animals↗

Mechanisms of optimized biventricular pacing in pulmonary stenosis: effects on left ventricular geometry in swine.

We tested the hypothesis that optimized biventricular pacing (BiVP) enhances cardiac output (CO) during critical pulmonary stenosis (PS) by attenuating distortions in left ventricular (LV) geometry. Following median sternotomy in six anesthetized pigs, heart block was induced by ethanol ablation. During epicardial, DDD BiVP, atrioventricular delay (AVD) was varied from 60 ms to 180 ms in 30 ms increments. At the AVD with the highest CO right-left delay (RLD) was varied from (+) 80 ms (RV first) to (-) 80 ms (LV first) in 20 ms increments. At each pacing setting, aortic flow, ECG, and LV diameter were measured in the control state (CON) and during PS, created by snaring the pulmonary artery until CO decreased 50%. Short axis LV echocardiograms were obtained at (+) and (-) 80 ms. In CON, RLD had no effect on function or geometry. During PS optimum BiVP resulted in significant increases in CO (1.12 L/min +/- 0.13 SEM at RLD =+ 40 ms versus 0.92 +/- 0.12 at RLD = 0 and 0.73 +/- 0.08 at RLD =-80), and LV fractional shortening (8.97%+/- 0.51% at RLD =+ 40 ms versus 7.34%+/- 0.58% at RLD = 0 and 6.21%+/- 0.66% at RLD =-80). In addition, LV eccentricity with (-) RLD was significantly different versus CON at both end-diastole (0.79 +/- 0.07 vs 1.02 +/- 0.03, P = 0.011 Student's t-test) and end-systole (0.83 +/- 0.05 vs 1.00 +/- 0.02, P = 0.017). However, with (+) RLD differences versus CON were not significant at either end-diastole (0.88 +/- 0.06 vs 0.99 +/- 0.03) or end-systole (0.92 +/- 0.03 vs 1.01 +/- 0.03). In swine hearts with PS, optimized BiVP increases CO, fractional shortening, and LV symmetry. BiVP warrants further study as treatment for acute postoperative heart failure.

Animals↗

Cariporide is cardioprotective after iatrogenic ventricular fibrillation in the intact swine heart.

BACKGROUND: We sought to introduce sodium-hydrogen exchange inhibition as prophylaxis against the development of ventricular dysfunction in the setting of implantable cardioverter defibrillator insertion in high-risk patients. Cariporide, shown to be safe in humans, was used to reproduce previous results in our laboratory that demonstrated that sodium-hydrogen exchange inhibition preserves left ventricular (LV) function after ventricular fibrillation (VF) and reperfusion. METHODS: Twelve pigs (weight, 35 to 55 kg) were divided into two groups of six. Baseline ventricular function studies were based on echocardiography, conductance, aortic flow, and LV pressure. Animals were given vehicle (control) or cariporide (3 mg/kg intravenously). Ten minutes later, hearts underwent 80 seconds of VF. After reperfusion for 40 minutes, function studies were repeated. RESULTS: Postmortem examination included measuring passive pressure-volume curves and myocardial water content. Systolic indices, including preload recruitable stroke work and ejection fraction, were significantly depressed from baseline after VF and reperfusion for control animals (preload recruitable stroke work, 30.13 +/- 0.59 [standard error of the mean] versus 43.85 +/- 2.60 mm Hg; ejection fraction, 25.7% +/- 2.4% versus 33.5% +/- 3.0%) but not for those in the cariporide group (preload recruitable stroke work, 38.36 +/- 1.87 versus 40.86 +/- 1.45 mm Hg; ejection fraction, 33.9% +/- 3.5% versus 32.8% +/- 3.9%). In vivo diastolic indices demonstrated trends toward diminished ventricular compliance in control animals but not in the cariporide group after VF and reperfusion. Control animals had significantly increased postmortem LV stiffness, myocardial water content, and normalized LV mass. CONCLUSIONS: Cariporide preserves LV function after 80 seconds of VF and 40 minutes of reperfusion. Cariporide may prove useful in patients with severe LV dysfunction undergoing VF for implantable cardioverter defibrillator testing.

Animals↗

Sodium-hydrogen exchange inhibition preserves ventricular function after ventricular fibrillation in the intact swine heart.

BACKGROUND: We tested the hypothesis that sodium-hydrogen exchange inhibition attenuates ventricular dysfunction after ischemia-reperfusion injury in the intact porcine heart. METHODS: Twelve pigs (weight, 30-45 kg) were evenly divided into 2 groups. Baseline ventricular function studies were based on echocardiography, conductance, aortic flow, and left ventricular pressure. Animals were given vehicle (control) or benzamide-N-(aminoiminomethl)-4-(4-[2-furanylcarbonyl]-1-piperazinyl)-3-(methylsulfonyl)methanesulfonate (BIIB 513; 3 mg/kg administered intravenously). Ten minutes later, hearts were subjected to 75 seconds of ventricular fibrillation. After reperfusion for 40 minutes, function studies were repeated. Hearts were arrested and excised. Postmortem data included passive pressure-volume curves and myocardial water content. RESULTS: Preload recruitable stroke work was significantly decreased from baseline after ischemia and reperfusion in the control group (27.7 +/- 2.5 vs 48.0 +/- 5.6 mm Hg [+/- SEM], P =.001) but not in the BIIB 513 group (43.0 +/- 5.8 vs 45.5 +/- 4.1 mm Hg, P = not significant). In vivo diastolic and postmortem passive left ventricular compliance were reduced after ischemia and reperfusion for control animals but remained unchanged for animals receiving BIIB 513. Time required to recover baseline blood pressure after ventricular fibrillation was significantly longer for control animals (159 +/- 15 vs 88 +/- 14 seconds [+/- SEM], P =.008). Myocardial water content (78.97% +/- 0.94% vs 77.86% +/- 0.46% [+/- SEM]) and normalized left ventricular mass (137.24 +/- 6.17 vs 128.41 +/- 1.96 g [+/- SEM]) were insignificantly increased in control animals. CONCLUSIONS: Sodium-hydrogen exchange inhibition attenuates ventricular dysfunction after 75 seconds of ventricular fibrillation and 40 minutes of reperfusion. This family of agents might prove useful in patients with severe left ventricular dysfunction undergoing ventricular fibrillation for implantable cardioverter defibrillator testing.

Animals↗