PubMed Health⌕ Search

PubMed · 15452473

Regional functional depression immediately after ventricular septal defect closure.

Abstract

Left ventricular ejection is depressed immediately after repair of ventricular septal defect (VSD). Postrepair functional depression seen after VSD closure could result from a reduction in preload. However, other mechanisms could be at work. Functional depression could also be caused by closure of a low-impedance path for left ventricular ejection, the introduction of a stiff akinetic patch, or the operation itself. We reasoned that functional depression mediated by changes in preload or afterload should symmetrically affect end-diastole and end-systole, whereas depression resulting from changes in septal mechanics should be localized. We, therefore, performed segmental wall-motion analysis on intraoperative echocardiograms from patients undergoing VSD and atrial septal defect repair. After VSD closure, there was an asymmetric change in left ventricular end-systolic segment length and a decrease in fractional segment shortening localized to the septal and lateral walls, whereas patients with atrial septal defect had a symmetric increase in fractional shortening. These results suggest that acute functional depression after VSD repair is a result of localized impairment of septal function.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Alexander Quinn, Santos E Cabreriza, Brianne F Blumenthal, Beth F Printz, Karen Altmann, Julie S Glickstein, Michael S Snyder, Ralph S Mosca, Jan M Quaegebeur, Jeffrey W Holmes, Henry M Spotnitz. 2004. Regional functional depression immediately after ventricular septal defect closure.. https://doi.org/10.1016/j.echo.2004.06.021

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

3D heart model for computer simulations in cardiac surgery.

For a satisfactory computer simulation, a model, which imitates a natural situation, is needed. The Human heart is an irregular 3D object and thus difficult to reproduce. Basic data was taken from Visible Human Dataset (VHD), National Library of Medicine. The heart area was cut out of the original cross-sections and different tissues segmented. All the slices also had to be aligned to assure precise overlapping of the structures. A 3D computer heart model with the resolution of 1mm was designed. The heart model was dedicated to simulations of heat transfer during heart surgery however, it is applicable also to other medical simulations.

Cardiac Surgical Procedures↗