PubMed Health⌕ Search

Biomedical subjects

Hirotoshi Ito

Publications and source records attributed to Hirotoshi Ito.

At least 19 recordsLinked to original sources

Diagnosis of breast tumors by contrast-enhanced MR imaging: comparison between the diagnostic performance of dynamic enhancement patterns and morphologic features.

PURPOSE: To compare the diagnostic performance of breast lesions by the enhancement patterns and morphologic criteria on magnetic resonance imaging (MRI). MATERIALS AND METHODS: Both T1-weighted 3D gradient-echo sequences with high temporal resolution and high-spatial-resolution MRI were performed on 190 patients with a total of 204 enhancing lesions (144 malignant and 60 benign). The enhancement patterns and morphologic features of each mass and nonmass lesion were analyzed, and the diagnostic performance was compared. RESULTS: The sensitivity and specificity of the morphologic criteria were statistically significantly higher than those of the enhancement patterns (sensitivity: P = 0.0012, specificity: P = 0.0003), and the A(z) values for the three observers were 0.900, 0.919, and 0.900. The diagnostic accuracy of the morphologic criteria for both types of lesions was superior, and the differences were statistically significant (mass: P = 0.0001, nonmass: P = 0.0389). CONCLUSION: The analysis of the morphologic features of enhancing breast lesions alone showed higher diagnostic performance; therefore, signal intensity (SI) time-course data may not be needed to diagnose malignant breast lesions.

Adult↗

Oculomotor nerve palsy evaluated by diffusion-tensor tractography.

INTRODUCTION: The aim of the study was to test the feasibility of the tractography technique based on diffusion-tensor imaging (DTI) for the assessment of small infarcts involving the brainstem. METHODS: A patient who presented with an isolated left third cranial nerve palsy underwent magnetic resonance examination. Images were obtained by use of a whole-body, 1.5-T imager. Data were transferred to an off-line workstation for fiber tracking. RESULTS: The conventional diffusion-weighted imaging (DWI) performed using a 5 mm slice thickness could only depict an equivocal hyperintensity lesion located at the left paramedian midbrain. An additional thin-slice DTI was performed immediately after the initial DWI using a 3 mm slice thickness and was able to delineate the lesion more clearly. Image postprocessing of thin-slice DTI data revealed that the lesion location involved the course of the third cranial nerve tract, corresponding with the patient's clinical symptoms. CONCLUSION: The tractography technique can be applied to assess fine neuronal structures of the brainstem, enabling direct clinicoradiological correlation of small infarcts involving this region.

Aged↗

Utility of delayed gadolinium-enhanced MRI (dGEMRIC) for qualitative evaluation of articular cartilage of patellofemoral joint.

Delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) was used for the measurement of relative proteoglycan depletion of articular cartilage in the patellofemoral (PF) joint following a proprietary protocol, which was compared with the X-ray images, proton density weighted MR images (PDWI) and arthroscopic findings. The study examined 30 knees. The ages ranged from 16 to 74 (average 40.3) years. The Gd-DTPA(2-)containing contrast medium was used in a single dose. The subjects were made to exercise the knee joint for 10 min; and MR images were taken 2 h after intravenous injection of contrast medium. T1-calculated images were produced and the region of interest (ROI) was set as follows. (1) ROI1: entire articular cartilage in a slice through the center of the patella. (2) ROI2: low signal region in T1-calculated images, which were set in a blind fashion by two observers. (3) ROI3: articular cartilage on one side that includes ROI2 where low signal region were detected (medial or lateral). ROI3 was set to examine the contrast of ROI2 with surrounding articular cartilage. The average T1 values of ROI1 was 393.5+/-33.6 ms for radiographic grade 0 and 361.3+/-11.1 ms for grade I, which showed a significant difference (P=0.036). The T1 value of ROI2 was 351.6+/-28.2 ms for grade I, 361.9+/-38.3 ms for grade II, 362.1+/-67.7 ms for grade III, and 297.8+/-54.1 ms for grade IV according to arthroscopic Outerbridge classification. All cases, that demonstrated decrease of T1 values on dGEMRIC (ROI2), showed abnormal arthroscopic or direct viewing findings. The ratio (ROI3/ROI2) in cases of only slight damage classified as Outerbridge grade I (6 cases) was an average of 1.04+/-0.02 and was 1.0 or greater in all cases, thereby indicating well-defined contrast with the surrounding cartilage. The diagnosis of damage in articular cartilage was possible in all 16 cases with radiographic K-L grade I on dGEMRIC, while the intensity changes were not found in 10 of 16 cases on PDWI. The dGEMRIC with a single-dose would be useful on a diagnosis of the area demonstrating early relative proteoglycan depletion in the articular cartilage of the PF joint prior to any discernible changes in the subchondral bone on X-ray images and exceeds to plain MR images for examining deterioration of articular cartilage.

Adolescent↗

Monoclonal antibody A7 coupled to magnetic particles as a contrast enhancing agent for magnetic resonance imaging of human colorectal carcinoma.

BACKGROUND: Local recurrence, the most frequent pattern of recurrence of rectal carcinoma, is almost always fatal. The difficulty of diagnosing local recurrence contributes importantly to the poor prognosis. METHODS: We coupled monoclonal antibody (Mab) A7, which reacts specifically with human colorectal carcinoma, to ferromagnetic lignosite (FML) particles to distinguish rectal carcinoma from other tissues by magnetic resonance (MR) imaging. We examined retention of immunoreactivity by the A7-FML complexes in vitro, and also their distribution in vivo according to radiolabeling and MR imaging when injected into nude mice bearing human colorectal carcinoma xenografts. RESULTS: A7-FML retained binding activity nearly identical to that of Mab A7. Significantly more (125)I-labeled A7-FML accumulated in engrafted tumors than did (125)I-labeled normal mouse IgG-FML complexes (P < 0.05). A7-FML disappeared rapidly from the blood. Normal tissues accumulated less (125)I-labeled A7-FML than tumors; this accumulation decreased linearly with time. In MR imaging, signal intensity was reduced in the tumor by the injection of A7-FML. CONCLUSIONS: A7-FML is potentially useful as a MR contrast enhancing agent for human colorectal carcinoma xenografts implanted subcutaneously.

Animals↗

Higher lesion conspicuity for SENSE dynamic MRI in detecting hypervascular hepatocellular carcinoma: analysis through the measurements of liver SNR and lesion-liver CNR comparison with conventional dynamic MRI.

The aim of our study was to compare the signal-to-noise ratio (SNR) of liver parenchyma and the contrast-to-noise ratio (CNR) of hypervascular hepatocellular carcinoma (HCC) between conventional and SENSE dynamic MRI. Thirty-one consecutive patients who were strongly suspected of having HCC were enrolled in our study. The subjects consisted of 20 men and 11 women aged 52 years to 79 years (mean 66.8 years). Dynamic MRI was performed for each patient, with SENSE (SENSE MRI) and without SENSE (conventional MRI) on separate days. For the quantitative analysis, the liver SNR and the lesion-liver CNR of 25 hypervascular HCCs detected on both conventional and SENSE dynamic MRI were measured. The liver SNR of the arterial phase and the portal venous phase was 84.1+/-24.7 and 104.7+/-34.3, respectively, in conventional MRI, while it was 62.9+/-19.5 and 44.5+/-18.2, respectively, in SENSE MRI. SENSE MRI showed a statistically significantly lower SNR than conventional MRI (P<0.01). The lesion-liver CNR was 26.3+/-15.9 in conventional MRI and 39.0+/-19.6 in SENSE MRI. The lesion-liver CNR in SENSE MRI was significantly higher than in conventional MRI (P<0.01). The SNR in SENSE MRI is significantly lower than in conventional MRI, although the lesion CNR is significantly higher than in conventional MRI.

Aged↗

The development and characterization of H5 influenza virus vaccines derived from a 2003 human isolate.

The pandemic threat posed by highly pathogenic H5N1 influenza A viruses has created an urgent need for vaccines to protect against H5 virus infection. Because pathogenic viruses grow poorly in chicken eggs and their virulence poses a biohazard to vaccine producers, avirulent viruses produced by reverse genetics have become the preferred basis for vaccine production. Here, we investigated two key characteristics of potential H5 vaccine candidates: the hemaggutinin (HA) cleavage site sequence and its modification to attenuate virulence and the choice of background virus to provide a high-growth rate. We produced recombinant (6:2 reassortant) viruses that possessed a series of modified avirulent-type HA and neuraminidase genes, both of which were derived from an H5N1 human isolate. The other genes of these recombinant viruses were derived from donor virus strains known to grow well in eggs: the human strain A/Puerto Rico/8/34 (PR8) or an avian strain. All of the recombinant viruses grew well in eggs, were avirulent in chicks, and protected animals against infection with a wild-type virus. However, one of the recombinant viruses with an avian virus background acquired a mutation in the HA cleavage site sequence that conferred virulence potential to this virus. Moreover, vaccine candidates with the avian virus background were more virulent than those with the human virus background. We conclude that 6:2 recombinant viruses with a PR8 background are more suitable than those with an avian virus background for vaccine development and that the HA cleavage site sequence must be modified to minimize the potential for a vaccine virus to convert to a virulent form.

Animals↗

Relationship between contrast enhancement on fluid-attenuated inversion recovery MR sequences and signal intensity on T2-weighted MR images: visual evaluation of brain tumors.

PURPOSE: To investigate the relationship between the degree of contrast enhancement in fluid-attenuated inversion recovery (FLAIR) sequences and tumor signal intensity on T2-weighted images. MATERIALS AND METHODS: A total of 96 patients suspected of having brain tumors were examined by MR imaging, and whenever a brain tumor with an enhancing part larger than the slice thickness was demonstrated on postcontrast T1-weighted images, postcontrast FLAIR images were additionally acquired. The tumor signal intensity on the T2-weighted images was visually classified as follows: equal or lower compared with normal cerebral cortex (group 1), higher than normal cortex (group 2), and as high as cerebrospinal fluid (CSF) (group 3). When a lesion contained several parts with different signal intensities on T2-weighted images, we assessed each part separately. In each group, we visually compared pre- and postcontrast FLAIR images and assessed whether tumor contrast enhancement was present. When contrast enhancement was present on FLAIR sequence, the degree of contrast enhancement in T1-weighted and FLAIR sequences was visually compared. RESULTS: Postcontrast T1-weighted images showed 46 enhancing lesions, including 48 parts, in 31 MR examinations. FLAIR images of the lesion-parts in group 1 (N=18) did not show significant contrast enhancement. In group 2 (N=12), all the parts were enhanced in FLAIR sequences, and three parts were enhanced more clearly in the FLAIR sequences than in the T1-weighted sequences. In group 3 (N=18), all the parts were enhanced equally or more clearly in the FLAIR sequences than in the T1-weighted sequences. CONCLUSION: The signal intensity in FLAIR sequences is largely influenced by both T1 and T2 relaxation time; there is a close relationship between the signal intensity of brain tumors on T2-weighted images and the degree of contrast enhancement on FLAIR sequences. When tumors have higher signal intensity than normal cortex on T2-weighted images, additional postcontrast FLAIR imaging may improve their depiction.

Adenoma↗

Effect of thin-section diffusion-weighted MR imaging on stroke diagnosis.

BACKGROUND AND PURPOSE: Diffusion-weighted (DW) imaging has limited spatial resolution, especially in the z direction. We decreased the section thickness of DW imaging to 3 mm to determine if this change improves the depiction of small infarcts and if it affects stroke diagnosis. METHODS: We studied conventional (5-mm section thickness, 1-mm intersection gap) and thin-section (3-mm section thickness, no intersection gap) DW imaging data in 49 patients with symptoms of acute cerebral ischemia. Two radiologists who were not aware of the clinical findings reviewed all images and diagnosed the stroke subtype according to the Trial of Org 10172 in Acute Stroke Treatment (TOAST) method. Accuracies of stroke diagnosis with an experienced neuroradiologist and with a second-year radiology resident were compared. To quantify lesion conspicuity, contrast-to-noise ratios (CNRs) were measured. The CNR of thin-section DW imaging was then divided by the CNR of conventional DW imaging to yield the relative CNR (rCNR). RESULTS: The experienced neuroradiologist made the correct final diagnoses in 78% of cases with conventional DW imaging, improving to 100% with thin-section DW imaging. The resident made the correct diagnoses in 71% of cases with conventional DW imaging, improving to 94% with thin-section DW imaging. Lesion conspicuity was improved on thin-section DW imaging (rCNR = 1.47 +/- 0.63), especially for supratentorial lesions (rCNR = 1.51 +/- 0.63). CONCLUSION: Compared with conventional DW imaging, thin-section DW imaging permitted better lesion conspicuity and more precise stroke diagnosis.

Aged↗

Tractography for arteriovenous malformations near the sensorimotor cortices.

We sought to use diffusion-tensor imaging-based tractography to assess the relationship between the arteriovenous malformations (AVM) and the sensorimotor cortices/tracts. Three patients who had an AVM closely situated to the sensorimotor tracts were studied. The relationship between the sensorimotor tracts and the AVM was well demonstrated in all patients. Tractography was also helpful in identifying the location of the motor cortex in some of the cases.

Adult↗

Stroke patients' evolving symptoms assessed by tractography.

PURPOSE: To test the hypothesis that an interval evolution in the location of the depicted sensorimotor tract relative to the infarct (the "tract-infarct relationship") may be related to stroke victims' symptom progression. MATERIALS AND METHODS: Patients (N = 7) who underwent multiple diffusion-tensor imaging (DTI) studies during symptomatic progression were included in this study. DTI was performed using a single-shot echo-planar imaging (EPI) technique with a motion-probing gradient in six orientations, a b-value of 800 seconds/mm2, and six image averages. The total scan time was four minutes and 24 seconds. Fiber-tracking of the sensorimotor pathways was performed, and the locations of these tracts were retrospectively assessed in relation to the evolution of the symptoms. RESULTS: Five of the seven patients showed an interval enlargement of the infarct on diffusion-weighted (DW) images. In two of these cases the lesion enlarged to involve the sensorimotor tracts, while in three cases the lesion enlarged only so far to come into close proximity to the sensorimotor tract. In the remaining two cases there was no interval enlargement of the infarct, and therefore the tract-infarct relationship could not account for the evolution of the symptoms in these cases. CONCLUSION: A tract-infarct relationship can be observed with the use of a fiber-tracking technique, and the results may improve our understanding of the symptom progression seen in stroke victims.

Adult↗

Fiber-tracking method reveals sensorimotor pathway involvement in stroke patients.

BACKGROUND AND PURPOSE: We tested the feasibility of a new MRI technique that provides visualization of the sensorimotor tracts in vivo in a group of stroke victims. SUMMARY OF REPORT: Fourteen patients with small infarctions involving the white matter of the supratentorial brain were evaluated. Sensorimotor tracts on the lesional and contralesional sides were successfully depicted in all cases. The position of the sensorimotor tracts relative to the infarct was in good agreement with clinical symptoms. The overall sensitivity and specificity for sensorimotor tract involvement were 100% and 77%, respectively. CONCLUSIONS: Our proposed fiber-tracking method was shown to be a clinically feasible technique that correlates well with clinical symptoms.

Aged↗

Optimization of TI values in inversion-recovery MR sequences for the depiction of fine structures within gray and white matter: separation of globus pallidus interna and externa.

RATIONALE AND OBJECTIVES: The authors' purpose was to search the inversion time (TI) values that enable the best differentiation of fine structures in gray matter (gray-gray differentiation). MATERIALS AND METHODS: Seven healthy adult volunteers with no history of neurologic disease or head trauma were recruited and gave their informed consent. The subjects consisted of two men and five women ranging in age from 25 to 38 years, with a mean age of 28 years +/- 5. The subjects were imaged with a turbo spin-echo inversion-recovery sequence. This sequence was performed in the axial plane at the level of the basal ganglia with the following parameters: repetition time, 3,200 msec; echo time, 15 msec; three signals acquired; echo train, seven; section thickness, 3 mm; matrix size, 256 x 256; and field of view, 180 mm. The tested values were TI = 100, 200, 300, 400, and 500 msec. Region-of interest measurements were performed at the following anatomic structures and represent gray-gray and white-white differentiations, respectively: globus pallidus externa versus globus pallidus interna, and optic radiation versus surrounding white matter. RESULTS: The maximum contrast index value occurred at TI = 400 msec for globus pallidus externa versus globus pallidus interna (P < .05) With the contrast-to-noise ratio, no significant difference in gray-gray differentiation was observed among the various TIs. The minimum signal-to-noise ratio of the gray matter occurred at TI = 400 msec (P < .05). A subjective evaluation revealed an overall superiority of gray-matter differentiation with TI = 400 msec. CONCLUSION: A TI of 400 msec was the most suitable for this purpose.

Adult↗

Brain fiber tracking with clinically feasible diffusion-tensor MR imaging: initial experience.

Two technical challenges must be overcome before brain fiber tracking with diffusion-tensor magnetic resonance (MR) imaging can be applied to clinical practice: Imaging time must be shortened, and image distortion must be minimized. Single-shot echo-planar MR imaging with parallel imaging technique enabled both objectives to be accomplished. Twenty-three consecutive patients with brain tumors underwent MR imaging with a 1.5-T whole-body MR system. Fiber tracts on the lesion side in the brain had varying degrees of displacement or disruption as a result of the tumor. Tract disruption resulted from direct tumor involvement, compression on the tract, and vasogenic edema surrounding the tumor. This diffusion-tensor MR imaging method with the parallel imaging technique allows clinically feasible brain fiber tracking.

Adolescent↗

Circular dichroism spectra of DNA quadruplexes [d(G(5)T(5))](4) as formed with G(4) and T(4) tetrads and [d(G(5)T(5)). d(A(5)C(5))]2 as formed with Watson-Crick-like (G-C)(2) and (T-A)(2) tetrads.

We utilize electrophoresis and find that a thermally treated equimolar mixture of the oligonucleotide d(G(5)T(5)) and its complementary oligonucleotide d(A(5)C(5)) exhibits either two bands or a single band in one lane, depending on the conditions of the incubation solutions. The thermally treated d(G(5)T(5)) solution loaded in a different lane exhibits a single band of the parallel quadruplex [d(G(5)T(5))](4), which is composed of homocyclic hydrogen-bonded G(4) and T(4) tetrads previously proposed. For the thermally treated equimolar mixture of d(G(5)T(5)) and d(A(5)C(5)), the fast band is assigned to a Watson-Crick d(G(5)T(5)). d(A(5)C(5)) duplex, so that the slow band with the same low mobility as that of [d(G(5)T(5))](4) may be assigned to either [d(G(5)T(5))](4) itself or a [d(G(5)T(5)). d(A(5)C(5))](2) quadruplex. If the latter compound is true, this may be the antiparallel quadruplex composed of the heterocyclic hydrogen-bonded G-C-G-C and T-A-T-A tetrads proposed previously. After removing these three bands for the duplex and two kinds of hypothetical quadruplexes, we electrophoretically elute the corresponding compounds in the same electrophoresis buffer using an electroeluter. The eluted compounds are ascertained to be stable by electrophoresis. The circular dichroism (CD) and UV absorption spectra measured for the three isolated compounds are found to be clearly different. For the electrophoretic elution of the hypothetical [d(G(5)T(5))](4) quadruplex, the result of the molecularity of n = 4 obtained from the CD melting curve analysis provides further support for the formation of the parallel [d(G(5)T(5))](4) quadruplex already proposed. For the thermally treated equimolar mixture of d(G(5)T(5)) and d(C(5)A(5)), the fast band with a molecularity of n = 2 corresponds to the Watson-Crick duplex, d(G(5)T(5)). d(A(5)C(5)). The slow band with a molecularity of n = 4 indicates the antiparallel quadruplex [d(G(5)T(5)). d(A(5)C(5))](2), whose observed CD and UV spectra are different from those of [d(G(5)T(5))](4). By electrophoresis, after reannealing the eluted compound [d(G(5)T(5)). d(A(5)C(5))](2), a distinct photograph showing the band splitting of this quadruplex band into the lower duplex and upper quadruplex bands is not possible; but by a transilluminator, we occasionally observe this band splitting with the naked eye. The linear response polarizability tensor calculations for the thus determined structures of the [d(G(5)T(5))](4) quadruplex, the McGavin-like [d(G(5)T(5)). d(A(5)C(5))](2) quadruplex, and the Watson-Crick d(G(5)T(5)). d(A(5)C(5)) duplex are found to qualitatively predict the observed CD and UV spectra.

Base Sequence↗