Radiation exposure during catheter ablation of atrial fibrillation.

BACKGROUND: The purpose of this study was to determine the radiation exposure during catheter ablation of atrial fibrillation (AF) using the pulmonary vein (PV) approach. METHODS AND RESULTS: The study included 15 patients with AF and 5 patients each with atrial flutter and atrioventricular nodal reentrant tachycardia (AVNRT) who underwent fluoroscopically guided procedures on a biplane x-ray system operated at a low-frame pulsed fluoroscopy (7.5 frames per second). Radiation exposure was measured directly with 50 to 60 thermoluminescent dosimeters (TLDs). Peak skin doses (PSDs), effective radiation doses, and risk of fatal malignancies were all computed. Mean fluoroscopy durations for AF procedures were 67.8+/-21 minutes in the right anterior oblique (RAO) and 61.9+/-16.6 minutes in the left anterior oblique (LAO) projection, significantly different from that required for atrial flutter and AVNRT. The mean PSDs measured with the TLDs were 1.0+/-0.5 Gy in the RAO and 1.5+/-0.4 Gy in the LAO projection. The lifetime risk of excess fatal malignancies normalized to 60 minutes of fluoroscopy was 0.07% for women and 0.1% for men. CONCLUSIONS: The relatively small amounts of the patient's radiation exposure in this study, despite the prolonged fluoroscopy durations, can be attributed to the use of very-low-frame pulsed fluoroscopy, the avoidance of magnification, and optimal adjustments of the fluoroscopy exposure rates. The resulting lifetime risk of fatal malignancy is within the range previously reported for standard supraventricular arrhythmias.

Adult↗

Electrocardiographic features of arrhythmogenic right ventricular dysplasia/cardiomyopathy according to disease severity: a need to broaden diagnostic criteria.

BACKGROUND: The purpose of this study was to systematically study diagnostic and prognostic electrocardiographic (ECG) characteristics of arrhythmogenic right ventricle dysplasia/cardiomyopathy (ARVD/C). METHODS AND RESULTS: The patient population included 50 patients with ARVD/C (27 males, 23 females; mean age 38+/-15 years). We also analyzed the ECG of 50 age- and gender-matched normal control subject and 28 consecutive patients who presented with right ventricular outflow tract (RVOT) tachycardia. Right bundle-branch block (RBBB) was present in 11 patients (22%). T-wave inversions in V1 through V3 were observed in 85% of ARVD/C patients in the absence of RBBB compared with none in RVOT and normal controls, respectively (P<0.0001); epsilon waves were seen in 33%, and a QRS duration > or =110 ms in V1 through V3 was present in 64% of patients. Among those without RBBB, our newly proposed criterion of "prolonged S-wave upstroke in V1 through V3" > or =55 ms was the most prevalent ECG feature (95%) and correlated with disease severity and induction of VT on electrophysiological study. This feature also best distinguished ARVD/C (diffuse and localized) from RVOT. CONCLUSIONS: A prolonged S-wave upstroke in V1 through V3 is the most frequent ECG finding in ARVD/C and should be considered as a diagnostic ECG marker.

Adult↗

Results of catheter ablation of typical atrial flutter.

The purpose of this study was to evaluate the safety and efficacy of radiofrequency (RF) ablation of typical atrial flutter by using an 8-mm electrode catheter and a 100-W RF power generator. A limitation of previous trials of catheter ablation of atrial flutter is that the data were not collected as part of a prospective multicenter clinical trial. The study results associated catheter ablation of typical atrial flutter in a cohort of 150 patients with an 88% acute efficacy rate. At 6-month follow-up, recurrent typical atrial flutter was observed in 13% of patients. Of the 12 patients with typical atrial flutter recurrence, 4 were symptomatic and 8 were asymptomatic. Procedure duration was a significant predictor of typical atrial flutter recurrence. The 12-month rate for development of atrial fibrillation was 30%. Catheter ablation of atrial flutter was associated with significant improvements in 5 of 8 domains of the Short Form 36 Survey (quality of life) and significant decreases in 13 of the 16 symptoms of the Symptom Checklist. The device- or procedure-related complication rate was 2.7%. Skin burns occurred at the dispersive pad site due to stronger RF power in 3 patients. Use of a dual dispersive pad system mitigated this problem. Thus, the results of this study associated catheter ablation of atrial flutter with high acute efficacy, a small risk of recurrent atrial flutter, and an important risk of atrial fibrillation during follow-up.

Aged↗

Modern pacemaker and implantable cardioverter/defibrillator systems can be magnetic resonance imaging safe: in vitro and in vivo assessment of safety and function at 1.5 T.

BACKGROUND: MRI has unparalleled soft-tissue imaging capabilities. The presence of devices such as pacemakers and implantable cardioverter/defibrillators (ICDs), however, is historically considered a contraindication to MRI. These devices are now smaller, with less magnetic material and improved electromagnetic interference protection. Our aim was to determine whether these modern systems can be used in an MR environment. METHODS AND RESULTS: We tested in vitro and in vivo lead heating, device function, force acting on the device, and image distortion at 1.5 T. Clinical MR protocols and in vivo measurements yielded temperature changes <0.5 degrees C. Older (manufactured before 2000) ICDs were damaged by the MR scans. Newer ICD systems and most pacemakers, however, were not. The maximal force acting on newer devices was <100 g. Modern (manufactured after 2000) ICD systems were implanted in dogs (n=18), and after 4 weeks, 3- to 4-hour MR scans were performed (n=15). No device dysfunction occurred. The images were of high quality with distortion dependent on the scan sequence and plane. Pacing threshold and intracardiac electrogram amplitude were unchanged over the 8 weeks, except in 1 animal that, after MRI, had a transient (<12 hours) capture failure. Pathological data of the scanned animals revealed very limited necrosis or fibrosis at the tip of the lead area, which was not different from controls (n=3) not subjected to MRI. CONCLUSIONS: These data suggest that certain modern pacemaker and ICD systems may indeed be MRI safe. This may have major clinical implications for current imaging practices.

Animals↗

Prophylactic defibrillator implantation in patients with nonischemic dilated cardiomyopathy.

BACKGROUND: Patients with nonischemic dilated cardiomyopathy are at substantial risk for sudden death from cardiac causes. However, the value of prophylactic implantation of an implantable cardioverter-defibrillator (ICD) to prevent sudden death in such patients is unknown. METHODS: We enrolled 458 patients with nonischemic dilated cardiomyopathy, a left ventricular ejection fraction of less than 36 percent, and premature ventricular complexes or nonsustained ventricular tachycardia. A total of 229 patients were randomly assigned to receive standard medical therapy, and 229 to receive standard medical therapy plus a single-chamber ICD. RESULTS: Patients were followed for a mean (+/-SD) of 29.0+/-14.4 months. The mean left ventricular ejection fraction was 21 percent. The vast majority of patients were treated with angiotensin-converting-enzyme (ACE) inhibitors (86 percent) and beta-blockers (85 percent). There were 68 deaths: 28 in the ICD group, as compared with 40 in the standard-therapy group (hazard ratio, 0.65; 95 percent confidence interval, 0.40 to 1.06; P=0.08). The mortality rate at two years was 14.1 percent in the standard-therapy group (annual mortality rate, 7 percent) and 7.9 percent in the ICD group. There were 17 sudden deaths from arrhythmia: 3 in the ICD group, as compared with 14 in the standard-therapy group (hazard ratio, 0.20; 95 percent confidence interval, 0.06 to 0.71; P=0.006). CONCLUSIONS: In patients with severe, nonischemic dilated cardiomyopathy who were treated with ACE inhibitors and beta-blockers, the implantation of a cardioverter-defibrillator significantly reduced the risk of sudden death from arrhythmia and was associated with a nonsignificant reduction in the risk of death from any cause.

Adrenergic beta-Antagonists↗

Implantable cardioverter-defibrillators in patients with arrhythmogenic right ventricular dysplasia/cardiomyopathy.

OBJECTIVES: The aim of this study was to assess the outcome of arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) patients treated with an implantable cardioverter-defibrillator (ICD). BACKGROUND: Arrhythmogenic right ventricular dysplasia/cardiomyopathy is associated with tachyarrhythmia and an increased risk of sudden death. METHODS: This study included 42 ARVD/C patients with ICDs (52% male, age 6 to 69 years, median 37 years) followed at our center. RESULTS: Mean follow-up was 42 +/- 26 months (range 4 to 135 months). Complications associated with ICD implantation included need for lead repositioning (n = 3) and system infection (n = 2). During follow-up, one patient died of a brain malignancy and one had heart transplantation. Lead replacement was required in six patients as a result of lead fracture and insulation damage (n = 4) or change in thresholds (n = 2). During this period, 33 of 42 (78%) patients received a median of 4 (range 1 to 75) appropriate ICD interventions. The median period between ICD implantation and the first firing was 9 months (range 0.1 to 66 months). The ICD firing storms were observed in five patients. Inappropriate interventions were seen in 10 patients. Predictors of appropriate firing were induction of ventricular tachycardia (VT) during electrophysiologic study (EPS) (84% vs. 44%, p = 0.024), detection of spontaneous VT (70% vs. 15%, p = 0.001), male versus female gender (91% vs. 65%, p = 0.04), and severe right ventricular dilation (39% vs. 0%, p = 0.013). Using multivariate analysis, VT induction during EPS was associated with increased risk for firing in ARVD/C patients; odds ratio 11.2 (95% confidence interval 1.23 to 101.24, p = 0.031). CONCLUSIONS: Patients with ARVD/C have a high arrhythmia rate requiring appropriate ICD interventions. The ICD therapy appears to be well tolerated and important in the management of patients with ARVD/C.

Adolescent↗

Magnetic resonance and computed tomography imaging of arrhythmogenic right ventricular dysplasia.

Arrhythmogenic right ventricular dysplasia (ARVD) is a familial cardiomyopathy that causes fibro-fatty replacement of the right ventricle (RV), leading to sudden death due to ventricular arrhythmias. The disease is an important cause of sudden death in individuals younger than 35 years of age. Structural and functional abnormalities of the RV constitute an important diagnostic criterion for the disease. Diagnosis of ARVD is often a challenge as conventional imaging modalities have significant limitations to visualize the RV. Recently, magnetic resonance imaging (MRI) and computed tomographic (CT) imaging have emerged as robust clinical tools for evaluation of myocardial pathology. In addition to providing morphologic and functional information, both imaging modalities have the ability to demonstrate intramyocardial fat, which is the pathological hallmark in ARVD. This article discusses the current status and role of MRI and CT imaging in the diagnosis of ARVD.

Arrhythmogenic Right Ventricular Dysplasia↗

Incidence of venous obstruction following insertion of an implantable cardioverter defibrillator. A study of systematic contrast venography on patients presenting for their first elective ICD generator replacement.

AIMS: The number of implantable cardioverter defibrillator (ICD) implantations, as well as follow-up procedures such as generator exchanges, lead revisions and lead system upgrades, is ever-increasing. Lead revisions and implantation of additional leads require venous access at the site of the previous ICD implantation. The aim of our study was therefore to evaluate the incidence of venous obstruction after chronic transvenous ICD system implantation. METHODS AND RESULTS: One hundred and five consecutive patients admitted for their first elective ICD generator replacement were included. All patients underwent bilateral contrast venography and the images were analyzed by two attending radiologists. Venous obstruction was classified as moderate stenosis (50-75% diameter reduction), severe stenosis (>75%) or total occlusion. Venous obstruction of various degrees was found in 25% of the patients. Complete occlusion was found in 9%, severe stenosis in 6% and moderate stenosis in 10% of the patients. The incidence of venous obstruction was increased in patients with a pacemaker prior to the initial ICD system implantation (67%). No difference was found in patients with a single defibrillator lead compared with patients who had an additional superior vena cava (SVC) shocking coil. However, the presence of a second shocking coil in the SVC incorporated in a single ICD lead was associated with an increased incidence of venous obstruction. No difference was found between silicone and polyurethane insulated leads. CONCLUSION: This study shows that venous obstruction occurs relatively frequently after ICD implantation. Therefore, contrast venography should always be obtained if malfunction of a preexistent lead is suspected or a system upgrade is considered.

Brachiocephalic Veins↗

Pulmonary vein occlusion: an unanticipated complication of catheter ablation of atrial fibrillation using the anatomic circumferential approach.

Favorable results of circumferential pulmonary vein (PV) ostial ablation guided by electroanatomic mapping (Carto) have fueled great enthusiasm for this technique. The lesion set for this ablation procedure as described by Pappone et al.(1,2) involves a figure of 8 lesions encompassing the 2 right and 2 left PV ostia with 2 additional linear lesions. Pulmonary vein stenosis/or occlusion has not previously been reported as a complication of this procedure. We describe PV occlusion after this procedure. Based on the occurrence of this previously unreported complication, we no longer create a figure '8' lesion around the right superior and inferior PVs. We anticipate that this complication can be avoided by creating a circular lesion encompassing the 2 PV ostia, while avoiding the linear lesion between the 2 PV ostia.

Adult↗

Stereotactic magnetic resonance guidance for anatomically targeted ablations of the fossa ovalis and the left atrium.

INTRODUCTION: Targets for radiofrequency ablation (RFA) of atrial fibrillation are increasingly being selected based on anatomic considerations. Because fluoroscopy provides only limited information about the relationship between catheter positions and cardiac structures, we evaluated whether stereotactic catheter guidance might facilitate anatomical catheter navigation and RFA to the great vessels, the fossa ovalis and the left atrium (LA). METHODS AND RESULTS: An electromagnetic catheter's position system was superimposed on three-dimensional (3D) MR images using fiducial markers. This allowed the dynamic display of the catheter position on the true anatomy of previously acquired MRI in real-time. To assess the reproducibility of RFA, repeat ablations were created at the identical anatomic site in the inferior vena cava (IVC) in 5 swine. Average distance of the repeated ablations was 4.4 +/- 2.4 mm.In five swine the catheter was anatomically guided with the MRI to the fossa ovalis and a single RFA was performed. On the pathological specimen all ablation sites were located within the fossa ovalis with an average distance of 3.9 +/- 2.1 mm from its center. In two of the experiments the ablation catheter was passed into the left atrium and anatomically targeted ablation performed in the lateral wall of the left atrial appendage. Catheter location and ablation site were confirmed by autopsy and histology. CONCLUSION: Real-time display of the catheter position on 3D-MRI allows anatomically targeted catheter navigation and RFA in the IVC, the fossa ovalis, and the left atrium. This may facilitate anatomically based interventions like septal puncture or pulmonary vein ablation and decrease fluoroscopy times.

Animals↗

Technique and results of pulmonary vein angiography in patients undergoing catheter ablation of atrial fibrillation.

INTRODUCTION: Delineation of pulmonary vein (PV) anatomy is an integral part of the PV isolation procedure. The aims of the present study were to (1) describe the technique of selective PV angiography, (2) show the typical fluoroscopic locations and appearance of the PVs, and (3) compare the ostial diameters of PVs measured by angiography and magnetic resonance imaging (MRI). METHODS AND RESULTS: Twenty consecutive patients undergoing a PV isolation procedure underwent selective PV angiography using a deflectable 8-French lumened catheter (Naviport, Cardima). The left superior PV (LSPV) runs upward and away from the spine in the right anterior oblique (RAO) projection and upward and toward the spine in the left anterior oblique (LAO) projection. The opposite is true for the right superior PV (RSPV). The left inferior PV (LIPV) has a bull's-eye appearance in the RAO projection, and the right inferior PV (RIPV) has a bull's-eye appearance in the LAO projection due to their end-on trajectories. The LIPV in the LAO projection and the RIPV in the RAO projection run horizontally toward the spine. An excellent correlation was noted in PV ostial size as assessed by angiography and MRI (r(2) < 0.90, P < 0.0001). CONCLUSION: This study describes the technique and results of PV angiography and fluoroscopy. The study also demonstrates good correlation of PV ostial diameters by contrast venography and MRI. PV angiography can be used as an alternate to MRI or computed tomographic imaging, particularly when these tests are unavailable or are contraindicated in the patient.

Atrial Fibrillation↗

Misdiagnosis of arrhythmogenic right ventricular dysplasia/cardiomyopathy.

INTRODUCTION: Diagnosis of arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) has major implications for the management of patients and their first-degree relatives. Diagnosis is based on a set of criteria proposed by the International Task Force for Cardiomyopathies. We report our experience in providing a re-evaluation for patients who previously have been diagnosed with ARVD/C. METHODS AND RESULTS: We studied 89 patients who requested a re-evaluation for diagnosis of ARVD/C at our center. Each of these patients had been diagnosed with ARVD/C at their initial evaluation. Each patient was re-evaluated with clinical history, physical examination, and noninvasive testing at our center. Invasive testing, which included electrophysiologic testing, right ventricular angiography, and endomyocardial biopsy, was performed when clinically indicated. Sixty (92%) of the 65 patients who had undergone magnetic resonance imaging (MRI) at an outside institution were reported to have an abnormal MRI consistent with ARVD/C. Among these patients, the only abnormality identified was the qualitative finding of intramyocardial fat/wall thinning in 46 patients. On re-evaluation, these qualitative findings were not confirmed. None of these 46 patients ultimately were diagnosed with ARVD/C. Among the entire patient group, only 24 (27%) of the 89 patients met the Task Force criteria for ARVD/C. CONCLUSION: This study demonstrates that the high frequency of "misdiagnosis" of ARVD/C is due to over-reliance on the presence of intramyocardial fat/wall thinning on MRI, incomplete diagnostic testing, and lack of awareness of the Task Force criteria. Diagnosis of ARVD/C cannot rely solely upon qualitative features on MRI.

Adolescent↗

Characterization of a new pulmonary vein variant using magnetic resonance angiography: incidence, imaging, and interventional implications of the "right top pulmonary vein".

INTRODUCTION: Catheter ablation of the pulmonary veins (PVs) for prevention of recurrent atrial fibrillation requires precise anatomic information. We describe the characteristics of a new anatomic variant of PV anatomy using magnetic resonance angiography. METHODS AND RESULTS: A 1.5-T magnetic resonance imaging system with a body coil or a torso phased-array coil was used before and after gadolinium injection. Magnetic resonance angiograms were acquired with a breath-hold three-dimensional fast spoiled gradient-echo imaging sequence in the coronal plane. Three-dimensional reconstruction with maximum intensity projections and multiplanar reformations was performed. A newly described variant PV ascending from the roof of the left atrium was found in 3 of 91 subjects. The mean ostial diameter of the roof PV was 7 +/- 2 mm, the mean distance from the ostium to the first branching point was 22 +/- 8.5 mm, and the mean distance to the right superior PV was 3.3 +/- 0.6 mm. CONCLUSION: We refer to the newly described variant of PV anatomy as the "right top pulmonary vein." It is important to be aware of this anatomic pattern to avoid inadvertent catheter intubation, which can result in misleading mapping results and PV stenosis.

Adult↗

Predictors of recurrence following catheter ablation of atrial fibrillation using an irrigated-tip ablation catheter.

INTRODUCTION: The aims of this study were to identify predictors of recurrence after catheter ablation of atrial fibrillation (AF) and to report the safety and efficacy of catheter ablation of AF using an irrigated-tip ablation catheter. METHODS AND RESULTS: Seventy-five consecutive patients (51 men [68%]; age 54 +/- 13 years) with symptomatic drug-refractory paroxysmal (42 patients), persistent (21 patients), or permanent (12 patients) AF underwent catheter ablation of AF using an irrigated-tip ablation catheter and a standard ablation strategy, which involved electrical isolation of all pulmonary veins (PVs) and creation of a cavotricuspid linear lesion. At 10.5 +/- 7.5 months of follow-up following a single (n = 75) or redo ablation procedure (n = 11), 39 (52%) of the 75 patients were free of AF, 10 were improved (13%), and 26 had experienced no benefit from the ablation procedure (35%). Seventy-six percent of patients with paroxysmal AF were free from recurrent AF. The most significant complications were two episodes of pericardial tamponade, mitral valve injury in one patient, two strokes, and complete but asymptomatic PV stenosis in one patient. Cox proportional hazards multivariate regression analysis identified the presence of persistent AF, permanent AF, and age >50 years prior to the ablation are the only independent predictors of AF recurrence after the first PV isolation procedure. CONCLUSION: Catheter ablation of AF using a strategy involving isolation of all PVs and creation of a linear lesion in the cavotricuspid isthmus using cooled radiofrequency energy is associated with moderate efficacy and an important risk for complications. The best results of this procedure are achieved in the subset of patients who are younger than 50 years and have only paroxysmal AF.

Adult↗