PubMed Health⌕ Search

Biomedical subjects

Hugh Calkins

Publications and source records attributed to Hugh Calkins.

At least 91 records · Page 5Linked to original sources

Cooled ablation.

Research on cooled ablation has been evolving for the last 10 years. Findings and current applications are reviewed. A cooled ablation catheter is approved by the FDA for use in idiopathic ventricular tachycardia (VT) patients, based on data originally submitted by Cardiac Pathways, Inc. This technology has subsequently been used by the clinicians in atrial flutter cases, nonischemic VT, epicardial accessory pathways, and atrial fibrillation. The experience at Johns Hopkins suggests that cooled radiofrequency ablation has utility in a variety of situations and in some instances has come to be the ablation system of choice.

Atrial Flutter↗

MRI of arrhythmogenic right ventricular cardiomyopathy/dysplasia.

Magnetic Resonance Imaging (MRI) is currently considered as the noninvasive modality of choice for evaluation of patients with suspected Arrhythmogenic Right Ventricular Dysplasia (i.e., right ventricular dysplasia). As arrhythmogenic right ventricular cardiomyopathy/dysplasia (ARVC/D) it is included in the WHO classification of cardiomyopathies. It has the unique ability to provide tissue characterization in addition to providing functional information. This article presents the basic techniques for the evaluation of right ventricular cardiomyopathy.

Arrhythmogenic Right Ventricular Dysplasia↗

Arrhythmogenic right ventricular dysplasia: ex vivo and in vivo fat detection with black-blood MR imaging.

PURPOSE: To assess electrocardiographically gated spin-echo (SE) and double inversion-recovery fast SE magnetic resonance (MR) imaging in the depiction of intramyocardial fat in cadaveric heart specimens and patients with arrhythmogenic right ventricular dysplasia (ARVD). MATERIALS AND METHODS: A phantom was used to determine the effective in-plane spatial resolution of SE and fast SE MR imaging protocols. Two cadavers with proved ARVD were imaged with identical sequences with spectrally selected fat suppression. Contrast-to-noise ratios (CNRs) of intramyocardial fat in the right ventricle (RV) were compared by using analysis of variance and Student t test with Bonferroni correction. Eleven patients with ARVD and 10 control subjects underwent fast SE MR imaging. Two blinded readers semiquantitatively evaluated images for fat conspicuity and image quality. RESULTS: Fast SE MR imaging achieved better spatial resolution but lower CNR than that of gated SE imaging. CNRs in cadaveric specimens were higher for double R-R than for single R-R fast SE sequences for all section thicknesses (P <.0001). Absolute CNR values were higher for fat-suppressed fast SE sequences than for those without fat suppression. Cadaveric specimens demonstrated fatty infiltration from epicardium toward endocardium of the RV free wall. Intramyocardial fat was detected in eight of 11 (73%) patients with ARVD and in no control subjects (P <.001). CONCLUSION: Intramyocardial fat detection in ARVD was better with fast SE MR imaging alone and combined with fat suppression than was gated SE MR imaging. When fast SE imaging is applied in vivo, however, breath-holding constraints limit the spatial resolution for RV fat detection.

Adipose Tissue↗

Anatomic stereotactic catheter ablation on three-dimensional magnetic resonance images in real time.

BACKGROUND: Targets for radiofrequency (RF) ablation of atrial fibrillation, atrial flutter, and nonidiopathic ventricular tachycardia are increasingly being selected on the basis of anatomic considerations. Because fluoroscopy provides only limited information about the relationship between catheter positions and cardiac structures and is associated with radiation risk, other approaches to mapping may be beneficial. METHODS AND RESULTS: An electromagnetic catheter positioning system was superimposed on 3D MR images using fiducial markers. This allowed the dynamic display of the catheter position on the true anatomy of previously acquired MR images in real time. In vitro accuracy and precision during catheter navigation were assessed in a phantom model and were 1.11+/-0.06 and 0.30+/-0.07 mm (mean+/-SEM), respectively. Left and right heart catheterization was performed in 7 swine without the use of fluoroscopy, yielding an in vivo accuracy and precision of 2.74+/-0.52 and 1.97+/-0.44 mm, respectively. To assess the reproducibility of RF ablation, RF lesions were created repeatedly at the identical anatomic site in the right atrium (n=8 swine). Average distance of the repeated right atrial ablations was 3.92+/-0.5 mm. Straight 3-point lines were created in the right and left ventricles to determine the ability to facilitate complex ablation procedures (n=6 swine). The ventricular lesions deviated 1.70+/-0.24 mm from a straight line, and the point distance differed by 2.25+/-0.63 mm from the pathological specimen. CONCLUSIONS: Real-time display of the catheter position on 3D MRI allows accurate and precise RF ablation guided by the true anatomy. This may facilitate anatomically based ablation procedures in, for instance, atrial fibrillation or nonidiopathic ventricular tachycardia and decrease radiation times.

Animals↗

Pulmonary vein anatomy in patients undergoing catheter ablation of atrial fibrillation: lessons learned by use of magnetic resonance imaging.

BACKGROUND: This study sought to define the technique and results of magnetic resonance imaging (MRI) of pulmonary vein (PV) anatomy before and after catheter ablation of atrial fibrillation (AF). METHODS AND RESULTS: Twenty-eight patients with AF underwent ablation. Patients underwent gadolinium-enhanced MRI before and 6 weeks after their procedures. A control group of 27 patients also underwent MRI. Variant PV anatomy was observed in 38% of patients. AF patients had larger PV diameters than control subjects, but no difference was observed in the size of the PV ostia among AF patients. The PV ostia were oblong in shape with an anteroposterior dimension less than the superoinferior dimension. The left PVs had a longer "neck" than the right PVs. A detectable PV narrowing was observed in 24% of veins. The severity of stenosis was severe in 1 vein (1.4%), moderate in 1 vein (1.4%), and mild in 15 veins (21.1%). All patients were asymptomatic, and none required treatment. CONCLUSIONS: This study demonstrates that AF patient have larger PVs than control subjects and demonstrates the value of MRI in facilitating AF ablation. The benefits of preprocedural MRI of PVs include the ability to evaluate the number, size, and shape of the PVs. MRI also provides an assessment of the severity of PV stenosis.

Atrial Fibrillation↗

Cardiac resynchronization and death from progressive heart failure: a meta-analysis of randomized controlled trials.

CONTEXT: Progressive heart failure is the most common mechanism of death among patients with advanced heart failure. Cardiac resynchronization, a pacemaker-based therapy for heart failure, enhances cardiac performance and quality of life, but its effect on mortality is uncertain. OBJECTIVE: To determine whether cardiac resynchronization reduces mortality from progressive heart failure. DATA SOURCES: MEDLINE (1966-2002), EMBASE (1980-2002), the Cochrane Controlled Trials Register (Second Quarter, 2002), The National Institutes of Health ClinicalTrials.gov database, the US Food and Drug Administration Web site, and reports presented at scientific meetings (1994-2002). Search terms included pacemaker, pacing, heart failure, dual-site, multisite, biventricular, resynchronization, and left ventricular preexcitation. STUDY SELECTION: Eligible studies were randomized controlled trials of cardiac resynchronization for the treatment of chronic symptomatic left ventricular dysfunction. Eligible studies reported death, hospitalization for heart failure, or ventricular arrhythmia as outcomes. Of the 6883 potentially relevant reports initially identified, 11 reports of 4 randomized trials with 1634 total patients were included in the meta-analysis. DATA EXTRACTION: Trial reports were reviewed independently by 2 investigators in an unblinded standardized manner. DATA SYNTHESIS: Follow-up in the included trials ranged from 3 to 6 months. Pooled data from the 4 selected studies showed that cardiac resynchronization reduced death from progressive heart failure by 51% relative to controls (odds ratio [OR], 0.49; 95% confidence interval [CI], 0.25-0.93). Progressive heart failure mortality was 1.7% for cardiac resynchronization patients and 3.5% for controls. Cardiac resynchronization also reduced heart failure hospitalization by 29% (OR, 0.71; 95% CI, 0.53-0.96) and showed a trend toward reducing all-cause mortality (OR, 0.77; 95% CI, 0.51-1.18). Cardiac resynchronization was not associated with a statistically significant effect on non-heart failure mortality (OR, 1.15; 95% CI, 0.65-2.02). Among patients with implantable cardioverter defibrillators, cardiac resynchronization had no clear impact on ventricular tachycardia or ventricular fibrillation (OR, 0.92; 95% CI, 0.67-1.27). CONCLUSIONS: Cardiac resynchronization reduces mortality from progressive heart failure in patients with symptomatic left ventricular dysfunction. This finding suggests that cardiac resynchronization may have a substantial impact on the most common mechanism of death among patients with advanced heart failure. Cardiac resynchronization also reduces heart failure hospitalization and shows a trend toward reducing all-cause mortality.

Cardiac Pacing, Artificial↗

Sympathoadrenal imbalance before neurocardiogenic syncope.

Neurocardiogenic syncope is the most common cause of acute loss of consciousness in adults. The present study attempted to identify neuroendocrine and hemodynamic changes before syncope that could therefore play a pathophysiologic role. Twenty-five patients referred for chronic orthostatic intolerance had plasma catecholamines measured serially; 21 patients during tilt-table testing (evoking syncope in 13) and 4 others with spontaneous syncope while supine. Forearm blood flow was measured by impedance plethysmography. All 12 patients with blood sampled before tilt-induced syncope had progressive, marked increases in plasma epinephrine levels (mean 11 times baseline, p <0.0001) before syncope. Simultaneously obtained norepinephrine levels increased to a much smaller extent than did epinephrine levels ("sympathoadrenal imbalance"). In the same patients, forearm vascular resistance decreased by 21% before syncope. Proportionate changes in forearm vascular resistance before syncope correlated negatively with those in the epinephrine:norepinephrine ratio (r = -0.75, p = 0.005). Patients without syncope had forearm vasoconstriction and no sympathoadrenal imbalance during tilt. Patients with syncope while supine also had sympathoadrenal imbalance before loss of consciousness. Sympathoadrenal imbalance precedes tilt-evoked and spontaneous neurocardiogenic syncope and correlates with concurrent skeletal muscle vasodilation. Sympathoadrenal imbalance may contribute to hemodynamic derangements precipitating neurocardiogenic syncope.

Adult↗

Real-time cardiac catheter navigation on three-dimensional CT images.

INTRODUCTION: Targets for ablation of atrial fibrillation, atrial flutter, and non-idiopathic ventricular tachycardia are increasingly being selected based on anatomic considerations. Because fluoroscopy provides only limited information about the relationship between catheter positions and cardiac structures, and is associated with radiation risk, other approaches to mapping may be beneficial. METHODS: The spatial and temporal information of an electromagnetic catheter tip position sensing system (Magellan, Biosense Inc.) was superimposed on a three-dimensional (3D) CT of the chest in swine using fiducial markers for image registration. Position and orientation of a 6 French catheter with an electromagnetic sensor was displayed in real-time on a corresponding 3D-CT. Catheter navigation within the heart and the great vessels was guided by detailed knowledge about catheter location in relation to cardiac anatomy. RESULTS: Anatomic structures including the atrial septum, pulmonary veins, and valvular apparatus were easily identified and used to direct catheter navigation. During the right heart examination, the catheter was navigated through the superior and inferior vena cava to predetermined anatomic locations in right atrium, right ventricle and pulmonary artery. The ablation catheter was also navigated successfully from the aorta through the aortic valve in the left ventricle. No complication was encountered during the experiments. The accuracy and precision of this novel approach to mapping was 4.69 +/- 1.70 mm and 2.22 +/- 0.69 mm, respectively. CONCLUSIONS: Real-time display of catheter position and orientation on 3D-CT scans allows accurate and precise catheter navigation in the heart. The detailed anatomic information may improve anatomically based procedures like pulmonary vein ablation and has the potential to decrease radiation times.

Animals↗

Initial experience with a novel focused ultrasound ablation system for ring ablation outside the pulmonary vein.

INTRODUCTION: Atrial fibrillation has been shown to initiate from triggers within pulmonary veins. Several studies have documented that electrical isolation of those triggers can lead to maintenance of sinus rhythm. The complication of pulmonary vein stenosis has limited the utility of delivering ablation energy within the pulmonary vein. We utilize a focused ultrasound catheter ablation system for delivery of transmural ablation lines proximal to the pulmonary vein ostium. METHODS: Nine dogs (weight 30-39 kg) were anesthetized and ventilated. Through a transseptal approach, pulmonary veins were engaged with the focused balloon ultrasound catheter. Ultrasound power was delivered at 40 acoustic watts outside the pulmonary vein ostium, focused 2 mm off the balloon surface, with a depth of approximately 6 mm, for 30-120 seconds. Following ablation, lesions were histopathologically analyzed. RESULTS: Of nine animals studied, fourteen pulmonary veins were ablated. We found successful delivery of near circumferential and transmural ablation lines in 6/14 pulmonary veins. In each of the six circumferential ablations, successful alignment of the ultrasound transducer along the longitudinal axis of the parabolic balloon occurred. The final four ablations were conducted with an enhanced catheter design that assured axial alignment. Of these ablations, all four were circumferential. The remaining 8 pulmonary veins had incomplete delivery of lesions. In each of these veins the ultrasound transducer was misaligned with the balloon axis when therapy was delivered. CONCLUSION: Focused ultrasound ablation is a new means of performing pulmonary vein isolation. This method provides delivery of lesions outside the vein, limiting the risk of pulmonary vein stenosis for the treatment of atrial fibrillation.

Animals↗

Filtered QRS duration on signal-averaged electrocardiography predicts inducibility of ventricular tachycardia in arrhythmogenic right ventricle dysplasia.

Treatment of arrhythmogenic right ventricular dysplasia (ARVD) is mostly based on the prevention of sudden cardiac death that results from arrhythmias. A clinical history suggestive of ARVD requires careful evaluation including electrophysiological study. The potential ability to identify those patients who will have inducible VT with electrophysiological study will enable better risk stratification and selection of vulnerable patients for electrophysiologically guided therapy. The purpose of the study was to evaluate the predictive ability of signal-averaged electrocardiography (SAECG) to predict inducibility of VT in patients with ARVD. The patient population consisted of 31 ARVD patients diagnosed with McKenna's criteria who underwent electrophysiological study. Electrophysiological study was considered positive if sustained monomorphic VT was induced. The sensitivity, specificity, and predictive accuracy of various SAECG criteria for inducibility of sustained monomorphic VT were also calculated. Twenty-one patients had inducible VT. The filtered QRS duration (fQRS), duration of signal <40 uV (LAS40), and root mean square voltage in the last 40 ms of QRS duration (RMS40) in ARVD patients induced versus noninduced were 122 +/- 21 and 103 +/- 8 ms (P=0.007), 45 +/- 20 and 28 +/- 14 ms (P=0.02), 19 +/- 19 and 32 +/- 22 uV (0.03), respectively. The ejection fractions were comparable in both groups. fQRS duration > or =110 ms had sensitivity of 91%, specificity of 90%, and a total predictive accuracy of 90% in predicting inducibility of VT in these patients. Filtered QRS duration on SAECG is predictive of electrophysiological study outcome in ARVD. Further studies will be needed to determine if SAECG results can predict the development of ventricular arrhythmias during follow-up.

Adult↗

Magnetic resonance imaging findings in patients meeting task force criteria for arrhythmogenic right ventricular dysplasia.

INTRODUCTION: Magnet resonance imaging (MRI) findings in patients meeting Task Force criteria for the diagnosis of arrhythmogenic right ventricular dysplasia (ARVD) have not been systematically described. We report qualitative and quantitative MRI findings in ARVD using state-of-the-art MRI. METHODS AND RESULTS: MRI was performed on 12 patients with ARVD who were prospectively diagnosed using the Task Force criteria. The imaging protocol included breath-hold double inversion recovery spin-echo and gradient-echo images. Ventricular volumes and dimensions were compared to 10 age- and sex-matched normal volunteers. High intramyocardial T1 signal similar to fat signal was observed in 9 (75%) of the 12 patients and in none of the controls. Right ventricular (RV) hypertrophy was seen in 5 (42%) patients, trabecular disarray in 7 (59%), and wall thinning in 3 (25%). Both the RV end-diastolic diameter and the outflow tract area were significantly higher in ARVD patients compared to controls (51.2 vs 43.2 mm, P < 0.01; and 14.5 vs 9.3 cm2, P < 0.01, respectively). ARVD patients had a higher RV end-diastolic volume index and lower RV ejection fraction compared with controls (127.4 vs 87.5, P < 0.01; and 41.6% vs 57%, P < 0.01, respectively). CONCLUSION: High intramyocardial T1 signal indicative of fat is seen in a high percentage (75%) of patients who meet the Task Force criteria for ARVD. Trabecular disarray is seen more frequently than wall thinning and aneurysms. RV dimensions and volumes differ significantly in ARVD compared to controls, indicating a role for quantitative evaluation in the diagnosis of ARVD.

Adolescent↗

Utility of SAECG in arrhythmogenic right ventricle dysplasia.

BACKGROUND: Arrhythmogenic right ventricular dysplasia (ARVD) is characterized by progressive replacement of RV myocardium with fibro-adipose tissue thought to be responsible for the presence of late potentials (LP) detected by SAECG. The general consensus on the role of SAECG in the diagnosis and prognosis of patients with ARVD is lacking. The purpose of this systematic review was to better define the role of SAECG in ARVD. METHODS: An extensive review of literature was done to specifically describe the prevalence of LP in ARVD and its determinants, explore the various options available to improve the diagnostic ability of SAECG, and provide recommendations for proper utilization of this technique. RESULTS: LPs are frequent in ARVD (47-100%), and more prevalent in severe disease and in patients with documented spontaneous VT. SAECG is a useful test in following the characteristic evolutivity of the disease. 4-16% of normal family members of patients with ARVD also have abnormal SAECG results. Detection of LP in ARVD can be improved by employing a high-pass filter of 25 Hz and specifically looking for changes in the Z leads. CONCLUSIONS: SAECG testing should be considered a standard part of the evaluation of patients with known or suspected ARVD. Further research is needed to confirm the value of SAECG testing in predicting arrhythmia risk and assessing the rate of disease progression, as well as to determine if greater prevalence of SAECG abnormalities in family members of patients with ARVD represents early detection of ARVD. The ongoing multidisciplinary study of right ventricular dysplasia will hopefully answer some of these questions.

Action Potentials↗