PubMed Health⌕ Search

Biomedical subjects

Hugh Calkins

Publications and source records attributed to Hugh Calkins.

102 records · Page 6Linked to original sources

Cerebral and systemic hemodynamics changes during upright tilt in chronic fatigue syndrome.

BACKGROUND AND PURPOSE: During head-up tilt (HUT), patients with chronic fatigue syndrome (CFS) have higher rates of neurally mediated hypotension (NMH) and postural tachycardia syndrome (POTS) than healthy controls. The authors studied whether patients with CFS were also more likely to have abnormal cerebral blood flow velocity (CBFV) compared with controls in response to orthostatic stress. METHODS: Transcranial Doppler monitoring of middle cerebral artery (MCA) CBFV was performed during 3-stage HUT prospectively in 26 patients with CFS and 23 healthy controls. At the same time, continuous monitoring of arterial blood pressure (BP), heart rate (HR), endtidal CO2 (ET-CO2) were performed. Results are reported as mean +/- SD. RESULTS: NMH developed in 21 patients with CFS and in 14 controls (P = .22). POTS was present in 9 CFS patients and 7 controls (P = .76). Supine HR was higher in CFS patients, but all other hemodynamics and CBFV measures were similar at baseline. The median time to hypotension did not differ, but the median time to onset of orthostatic symptoms was shorter in those with CFS (P < .001). The CBFV did not differ between groups in the supine posture, at 1 or 5 minutes after upright tilt, at 5 or 1 minute before the end of the test, or at termination of the test. Mean CBFV fell at termination of tilt testing in those with CFS and controls. ET-CO2 was lower at termination of the test in those with CFS versus controls (P = .002). CONCLUSIONS: The results of this study are not consistent with the hypothesis that patients with CFS have a distinctive pattern of MCA CBFV changes in response to orthostatic stress.

Adult↗

Prospective randomized comparison of cooled radiofrequency versus standard radiofrequency energy for ablation of typical atrial flutter.

In patients with atrial flutter, conventional RF ablation may not result in complete isthmus block. This prospective, randomized study tested the hypothesis that the cooled RF ablation is safe and facilitates the achievement of isthmus block with fewer RF applications than with standard ablation for typical atrial flutter. Isthmus ablation was performed in 59 patients (40 men, 64 +/- 14 years) with type I atrial flutter using standard RF (n = 31) or cooled RF (n = 28) catheters with crossover after 12 unsuccessful RF applications. The endpoint was bidirectional isthmus block or a total of 24 unsuccessful RF applications. After the first 12 RF applications, 17 (55%) of 31 standard RF and 22 (79%) of 28 cooled RF patients had bidirectional isthmus block (P < 0.05). After the remaining patients crossed over to the alternate RF ablation system and underwent up to 12 more RF applications, bidirectional isthmus block had been demonstrated in 27 (87%) of 31 standard RF and 25 (89%) of 28 cooled RF patients (P = NS). Isthmus block was not achieved within 24 RF applications in four standard and three cooled RF patients. Mean measured tip temperatures for cooled RF were lower than for standard RF (38.5 degrees C +/- 6.98 degrees C vs 57.2 degrees C +/- 7.42 degrees C, P < 0.0001). Peak temperatures were also lower for cooled RF compared to standard RF (45.7 degrees C +/- 22.7 degrees C vs 63.4 degrees C +/- 9.87 degrees C, P < 0.0001). Importantly, mean power delivered was significantly higher for cooled than for standard RF (42.3 +/- 9.48 vs 34.0 +/- 14.0 W, P < 0.0001). There were no serious complications for either ablation system. During a 12.8 +/- 3.76-month follow-up, there were two atrial flutter recurrences in the cooled RF group and four in the standard RF group (P = NS). In patients with type I atrial flutter, ablation with the cooled RF catheter is as safe as, and facilitates creation of bidirectional isthmus block more rapidly than, standard RF ablation.

Atrial Flutter↗

Catheter ablation of atrial flutter and macroreentrant atrial tachycardia.

Catheter ablation has evolved from an experimental technique to first-line therapy for the treatment of atrial flutter. Atrial flutter is characterized by a macroreentrant atrial tachycardia circuit. Successful ablation of atrial flutter involves (1) mapping the atrial flutter to define the conduction zones within the re-entrant circuit to determine whether the atrial flutter is isthmus-dependent, non-isthmus-dependent, or atypical; (2) interrupting the atrial flutter macroreentrant circuit with an ablation catheter by creating either focal or linear lesions within a critical zone of slow conduction that extends to anatomical borders; and (3) terminating the tachycardia and demonstrating conduction block within the atrial flutter circuit after ablation. This update discusses the classification schemes of atrial flutter and macroreentrant atrial tachycardias, reviews the technique of radiofrequency catheter ablation, and highlights recent ablation approaches for atrial flutters and macroreentrant atrial tachycardias.

Atrial Flutter↗

Catheter ablation therapy for atrial fibrillation.

Since cases were first reported in 1994, catheter ablation of atrial fibrillation has undergone rapid development and expansion. The procedure began as an attempt to recreate the Maze III operation with a catheter technique. Understanding the contribution of the pulmonary veins to the initiation and maintenance of atrial fibrillation led to dramatic changes in procedural technique. The segmental ostial and the circumferential approaches have emerged as the 2 dominant methods. Efforts continue in academic centers to better understand the pathophysiology of the arrhythmia and to further refine the ablation procedure to improve patient outcomes.

Atrial Fibrillation↗