Profile of clear corneal cataract incisions demonstrated by ocular coherence tomography.

PURPOSE: To examine the profile of clear corneal cataract incisions in the living eye using optical coherence tomography (OCT). SETTING: Private practice, Eugene, Oregon, USA. METHODS: The Zeiss Visante OCT anterior segment imaging system was used to study the profile of clear corneal cataract incisions, all in senior citizens. The OCT images of the operative eye were taken on the first postoperative day approximately 24 hours after surgery. The OCT images of clear corneal incisions were compared with an OCT image of a control eye, incisions without stromal hydration, and previous drawings of clear corneal incisions. RESULTS: In the images, the clear corneal incisions had an arcuate configuration rather than a straight line configuration, as previously indicated. This architecture appears to add greater stability as a result of a tongue-and-groove-like fit of the floor to the roof of the incision as well as an incision that is longer than the chord length that had previously been measured. Other findings include that stromal swelling, which facilitates sealing of these incisions by the endothelial pump, lasted for at least 24 hours. CONCLUSIONS: Results indicate an incision in the plane of the cornea with a chord length of at least 2.0 mm provides advantageous architecture for adequate self-sealing. Proper clear corneal incision construction resulted in an incision architecture that seemed to have increased stability and added safety, contributing to an absence of endophthalmitis for more than 10 years and 9000 cases in a single practice.

Cataract Extraction↗

Intraocular pressure during phacoemulsification.

PURPOSE: To assess changes in intraocular pressure (IOP) during standard coaxial or bimanual microincision phacoemulsification. SETTING: Oregon Eye Center, Eugene, Oregon, USA. METHODS: Bimanual microincision phacoemulsification (microphaco) was performed in 3 cadaver eyes, and standard coaxial phacoemulsification was performed in 1 cadaver eye. A pressure transducer placed in the vitreous cavity recorded IOP at 100 readings per second. The phacoemulsification procedure was broken down into 8 stages, and mean IOP was calculated across each stage. Intraocular pressure was measured during bimanual microphaco through 2 different incision sizes and with and without the Cruise Control (Staar Surgical) connected to the aspiration line. RESULTS: Intraocular pressure exceeded 60 mm Hg (retinal perfusion pressure) during both standard coaxial and bimanual microphaco procedures. The highest IOP occurred during hydrodissection, ophthalmic viscosurgical device injection, and intraocular lens insertion. For the 8 stages of the phacoemulsification procedure delineated in this study, IOP was lower for at least 1 of the bimanual microphaco eyes compared with the standard coaxial phaco eye in 4 of the stages (hydro steps, nuclear disassembly, irritation/aspiration, anterior chamber reformation). CONCLUSION: There was no consistent difference in IOP between the bimanual microphaco eyes and the eye that had standard coaxial phacoemulsification. Bimanual microincision phacoemulsification appears to be as safe as standard small incision phacoemulsification with regard to IOP.

Anterior Chamber↗

Clinical evaluation of the Crystalens AT-45 accommodating intraocular lens: results of the U.S. Food and Drug Administration clinical trial.

PURPOSE: To evaluate the 12-month U.S. phase II clinical trial results of the Crystalens AT-45 (eyeonics, Inc.) intraocular lens (IOL) used to provide uncorrected distance, intermediate, and near visual acuities in patients having cataract extraction and to compare in a substudy the contrast sensitivity and near visual acuity in patients with the Crystalens AT-45 IOL and those receiving a standard IOL. SETTING: Fourteen clinical sites throughout the U.S. for efficacy and 3 non-U.S. sites for safety and efficacy. METHODS: Patients 50 years or older had small-incision cataract extraction with implantation of the Crystalens AT-45 IOL. Unilateral implantation was followed by fellow-eye implantation. Postoperatively, uncorrected distance, near, and intermediate visual acuities were determined. Near and intermediate visual acuities were tested through a distance correction to eliminate potential pseudoaccommodative effects of residual myopia and corneal cylinder. A substudy tested contrast sensitivity under mesopic conditions with and without glare, as well as visual acuity in a subset of Crystalens AT-45 patients and a control group receiving a standard IOL. RESULTS: A total of 263 patients participated in the U.S. clinical trial and had 1 year of follow-up. Near visual acuities through the distance correction of 20/40 (J3) or better, monocularly and bilaterally, respectively, were seen in 90.1% and 100%; intermediate near visual acuities were seen in 99.6% and 100%. More than half the bilaterally implanted Crystalens AT-45 patients achieved uncorrected near acuity of 20/25 (J1) or better through the distance correction, and 84% achieved 20/32 (J2) or better. In the substudy, monocular near vision through the distance correction of 20/25 (J1) or better was seen in 50.4% with the Crystalens AT-45 IOL and in 4.7% with the standard IOLs. Mesopic contrast sensitivity results with and without glare for the Crystalens AT-45 were similar to those with standard monofocal IOLs. Nearly all patients (74 patients; 97.3%) who bilaterally were within 0.50 diopter of plano postoperatively achieved 20/32 (J2) or better uncorrected near, intermediate, and distance visual acuities. CONCLUSIONS: The Crystalens AT-45 accommodating IOL provided good uncorrected near, intermediate, and distance vision in pseudophakic patients. Contrast sensitivity with the Crystalens AT-45 was not diminished relative to standard monofocal IOLs, and near and intermediate visual performance was significantly better than with standard IOLs.

Accommodation, Ocular↗

Scleral fixation using suture retrieval through a scleral tunnel.

Scleral fixation of intraocular lenses (IOLs) can be performed under the protection of a scleral flap. A variation of this technique uses a scleral tunnel for suture fixation to the eye. Passage of a double-armed suture through the roof of the scleral tunnel with subsequent retrieval of the suture ends through the external incision for tying facilitates scleral fixation. This modification offers several advantages: A scleral tunnel is easier to construct than a triangular flap and does not require suture closure. It affords a greater surface area for suture placement through an ab externo or ab interno approach. Tying each suture allows the suture knot to pass under the roof of the tunnel, eliminating the need for suture knot rotation. Suture retrieval and scleral fixation through a scleral tunnel incision offers a simplified and elegant method for fixation of IOLs and other intraocular adjunctive devices.

Humans↗

Scleral fixation without conjunctival dissection.

Scleral fixation of intraocular lenses (IOLs) and adjunctive capsular devices can be performed under the protection of a scleral flap. A modification of this technique uses a scleral pocket initiated through a peripheral clear corneal incision. Full-thickness passage of a double-armed suture through the scleral pocket and conjunctiva, with subsequent retrieval of the suture ends through the external incision for tying, facilitates scleral fixation. This modification offers several advantages over traditional methods: It eliminates the need for conjunctival dissection and scleral cauterization; a scleral pocket affords a greater surface area for suture placement through an ab externo or ab interno approach; retrieval of the sutures through the external corneal incision and subsequent tying allows the suture knot to pass under the protective roof of the scleral pocket, negating the need for suture knot rotation; and the architecture of the scleral pocket eliminates the need for sutured wound closure. Suture retrieval and scleral fixation through a corneoscleral pocket offers a refined method for fixation of IOLs and other intraocular adjunctive devices.

Conjunctiva↗

Refractive lens surgery.

This article compares methods of axial length measurement for determining intraocular lens power and describes bimanual micro incision phacoemulsification for refractive lens exchange and routine cataract surgery, which offers an enormous advantage of maintaining a more stable intraocular environment during lens removal. This advantage may be especially important in high myopes who are at a greater risk for retinal detachment following lens extraction.

Humans↗

Contrast sensitivity and measuring cataract outcomes.

Clinical research has demonstrated the the continuous decline of the contrast sensitivity with age results from increasing spherical aberration of the human crystalline lens. Replacing the crystalline lens with appropriate modeled pseudophakic lens can provide superior contrast sensitivity and functional vision. As advances in the technology allow cataract and refractive surgeons to address higher-order optical aberrations, the measurement of functional vision becomes increasingly critical as a gauge of the progress. Contrast sensitivity testing is assuming a prominent place in the evaluation of surgical modalities because it reflects functional vision, correlates with visual performance, and provide a key to understanding optical and visual processing of images.

Cataract↗

The physics of phaco: a review.

Despite its unparalleled success in the field of surgery, the precise mechanism of ultrasonic phacoemulsification cataract extraction remains controversial. We review the relevant peer-reviewed literature on the subject of power generation and tip-tissue interactions to clarify the current status of our knowledge. We conclude that phacoemulsification most likely operates by a combination of mechanisms, including direct action of the vibrating tip against tissue and indirect cavitational effects. Surgeons will benefit from understanding the physical principles underlying phacoemulsification because they will be better able to evaluate the performance of various parameters and different machine settings.

Acoustics↗

New phacoemulsification technology.

PURPOSE OF REVIEW: Familiarization with each of the manufacturers' latest machines and upgrades assists in understanding the advances made in phacoemulsification technology. RECENT FINDINGS: Improvements in the delivery of energy through power modulations, alternative and adjunctive energy sources, and advanced fluidics allow the safe use of bimanual microincision techniques for lens extraction. SUMMARY: Continual advances in phacoemulsification technology and adjunctive surgical devices allow cataract surgery to be performed more safely and efficiently.

Humans↗

Surgical glove-associated diffuse lamellar keratitis.

PURPOSE: To demonstrate a potential cause of a prolonged epidemic of diffuse lamellar keratitis (DLK). METHOD: This retrospective review analyzed an epidemic of diffuse lamellar keratitis over a 3-year period in a single surgery center. Altering the brand of surgical gloves used during surgery was associated with an elimination of the DLK epidemic. Optical microscopy, scanning electron microscopy-energy dispersive spectroscopy (SEM-EDS), and Fourier transform infrared (FTIR) spectroscopy were performed on both brands of surgical gloves to allow for comparisons and determine possible surface contaminants responsible for the DLK outbreaks. RESULTS: The incidence of DLK during the epidemic ranged from 2% to 38% on a quarterly basis for the 3-year period. A change in the brand of surgical gloves resulted in a cessation of DLK. Surface analysis of both brands of gloves revealed extensive silicone oil contamination on the internal and external surfaces of the DLK-associated gloves and insignificant amounts of silicone oil on the external surface of the DLK-free gloves. CONCLUSION: Silicone oil contamination of surgical gloves appears to be associated with epidemic DLK.

Corneal Stroma↗

Optimizing refractive lens exchange with bimanual microincision phacoemulsification.

Bimanual microincision phacoemulsification entails the removal of the crystalline lens through 2 1.2 mm incisions. Infusion is provided through a separate irrigating handpiece, and phacoemulsification and aspiration are performed through a sleeveless phacoemulsification needle. We describe a technique for refractive lens exchange using bimanual microincision phacoemulsification. Capsulorhexis formation, cortical cleaving hydrodissection, lens extraction in the iris plane, and residual cortex removal are performed through the microincisions. This technique offers improved surgeon control throughout the procedure and added safety by maintaining continuous pressurization of the eye while removing the lens far from the posterior capsule.

Anterior Chamber↗

Retained IOL fragment and corneal decompensation after pseudophakic IOL exchange.

A 72-year-old man had exchange of a foldable silicone multifocal intraocular lens (IOL) by transection, removal, and monofocal IOL replacement. One month after the exchange, irreversible corneal edema developed and penetrating keratoplasty was performed. At the time of the corneal transplant, a small silicone fragment was discovered in and removed from the anterior chamber. Histologic evaluation of the patient's cornea demonstrated an absence of corneal endothelium, suggesting the fragment was the etiology of the corneal decompensation.

Aged↗

Power modulations in new phacoemulsification technology: improved outcomes.

PURPOSE: To evaluate the clinical outcomes of new phacoemulsification technology. SETTING: Oregon Eye Institute, Eugene, Oregon, USA. METHODS: After optimization of surgical parameters, patients were randomly assigned to cataract extraction with 1 of 4 phacoemulsification machines using new technology available within the past 1 to 2 years. Outcomes were compared with previously published results for these same machines obtained before the advent of the new technology. RESULTS: Improvements in effective phaco time, average phaco power, percentage of clear corneas, and 20/40 or better uncorrected visual acuity at the first postoperative visit were noted for most systems using new technology. CONCLUSION: New phacoemulsification technology offers surgical advantages that translate into improved clinical outcomes.

Aged↗