PubMed Health⌕ Search

Biomedical subjects

I Howard Fine

Publications and source records attributed to I Howard Fine.

At least 37 records · Page 2Linked to original sources

Improved functional vision with a modified prolate intraocular lens.

PURPOSE: To evaluate whether the Tecnis Z9000 intraocular lens (IOL) (Pfizer) with a modified prolate anterior surface provides better quality of vision than a conventional spherical IOL. SETTING: Oregon Eye Institute, Eugene, Oregon, USA. METHODS: Patients presenting for cataract surgery who were randomly assigned to receive a Tecnis Z9000 IOL (Pfizer) or a Sensar OptiEdge AR40e IOL (AMO) in 1 eye were followed for 3 months postoperatively. The patient could elect to have the same type of IOL implanted in the fellow eye. The results of sine-wave grating contrast sensitivity testing under mesopic and photopic conditions were compared interindividually. RESULTS: Monocular comparison was made between the 2 IOL groups, which comprised 15 patients each. The Tecnis IOL provided significantly better contrast sensitivity at 6 cycles per degree (cpd) under photopic conditions and at 1.5 and 3 cpd under mesopic conditions. Seven patients with a Tecnis IOL and 9 patients with an AR40e IOL had subsequent implantation in the fellow eye. In all eyes, including fellow eyes, having IOL implantation, the Tecnis provided significantly better contrast sensitivity at 3 and 6 cpd under photopic conditions and at 1.5, 3, and 6 cpd under mesopic conditions. The mean contrast sensitivity in fellow eyes showed that the Tecnis IOL produced significantly better results at some spatial frequencies. CONCLUSIONS: Results show the Tecnis IOL with a modified prolate anterior surface may produce better contrast sensitivity than a standard spherical IOL under mesopic and photopic conditions. Because contrast sensitivity testing correlates well with functional vision, a goal of future research should be to evaluate patient performance using functional tests such as driving simulation.

Aged↗

Bimanual bipolar diathermy for recurrent hyphema after anterior segment intraocular surgery.

Phacoemulsification with mechanical pupil dilation was performed on a functionally monocular glaucoma patient with pseudoexfoliation syndrome. The postoperative course was complicated by persistent intraocular hemorrhaging from the pupil margin in multiple locations that ceased temporarily with a marked elevation in intraocular pressure (IOP). Normalization of IOP with medication or paracentesis resulted in recurrent bleeding and a subsequent increase in IOP elevation. Surgical intervention using bipolar diathermy was required to control the bleeding and the elevated IOP. A bimanual approach allowed the corrective procedure to be performed in a simple and efficacious manner.

Aged↗

Intraocular lens power calculation after incisional and thermal keratorefractive surgery.

PURPOSE: To evaluate the efficacy of corneal topography in determining the central corneal refractive power in intraocular lens (IOL) power calculations after incisional and thermal keratorefractive surgery. SETTING: Oregon Eye Institute, Eugene, Oregon, USA. METHODS: This retrospective review comprised 20 eyes (14 patients) that had cataract extraction with IOL implantation or refractive lens exchange after radial keratotomy, hexagonal keratotomy, or laser thermal keratoplasty. The effective refractive power (EffRP) of the Holladay Diagnostic Summary on the EyeSys Corneal Analysis System was used to determine the central corneal refractive power, which was input into the Holladay 2 IOL calculation formula. RESULTS: Eighty percent of eyes achieved a postoperative spherical equivalent refraction within +/-0.50 diopter of emmetropia. CONCLUSION: The use of the EffRP increases the likelihood of an acceptable refractive outcome after cataract or refractive lens exchange surgery in eyes with a history of keratorefractive surgery.

Cataract Extraction↗

Refractive lens exchange as a refractive surgery modality.

PURPOSE OF REVIEW: Refractive lens exchange is becoming a more popular method of refractive surgery in the presbyopic patient. The limitations of keratorefractive surgery have led to a resurgence of lens exchange surgery for patients with prescriptions outside the limits of corneal refractive procedures, in addition to patients with routine refractive errors requesting a surgical procedure to achieve emmetropia and also address presbyopia. A review of the recent literature was performed to determine recent advances in this surgical procedure. RECENT FINDINGS: New multifocal and accommodative lens technology should enhance patient satisfaction. In addition, newer lens extraction techniques using microincisions and new phacoemulsification technology will enhance the safety of this procedure, ultimately allowing refractive lens exchanges to be performed through two microincisions as future lens technologies become available. SUMMARY: Attention to detail in regard to proper patient selection, preoperative measurements, intraoperative technique, and postoperative management has resulted in excellent outcomes and improved patient acceptance of this effective technique.

Humans↗

Wavefront technology in cataract surgery.

PURPOSE OF REVIEW: As advances in technology allow cataract surgeons to address higher order optical aberrations, the measurement of functional vision becomes increasingly critical. Contrast sensitivity testing is assuming a prominent place in our evaluation of surgical modalities because it reflects functional vision and correlates with visual performance. The Tecnis Z9000 intraocular lens (IOL) (Pfizer, New York) is the first foldable IOL designed to correct higher order optical aberrations and represents a first step toward the integration of wavefront technology and cataract surgery. RECENT FINDINGS: Contrast sensitivity declines with age, even in the absence of ocular pathology. Wavefront science demonstrates that the youthful crystalline lens compensates for aberrations in the cornea. The aging lens loses its balance with the cornea, as both the magnitude and the sign of its spherical aberration change. Older pseudophakic patients have generally the same contrast sensitivity as their age-matched counterparts without cataract. The Tecnis Z9000 IOL (Pfizer, New York) has been designed with a modified prolate anterior surface to compensate for the spherical aberration of the cornea, thus eliminating total ocular spherical aberration. Clinical data demonstrate that this modified prolate IOL provides superior functional vision, similar to that of younger people, and hence improves visual performance when compared with conventional spherical IOLs. It appears likely that the decline in functional vision with age involves changes in the spherical aberration of the crystalline lens. SUMMARY: The integration of wave-front technology and lens-based surgery represents a step toward improving functional vision and quality of life for cataract patients.

Cataract Extraction↗

Management of posterior polar cataract.

In this technique for managing posterior polar cataract, extreme care is taken not to overpressurize the anterior chamber or capsular bag to prevent posterior capsule rupture. Minimal hydrodissection and hydrodelineation are performed. The nucleus is extracted using minimal ultrasound energy. Viscodissection is used as a primary technique to mobilize the epinucleus and cortex. A protective layer is preserved over the posterior polar region until the conclusion of the extraction procedure to minimize the risk of loss of lens material into the vitreous cavity in the case of a capsule defect.

Capsulorhexis↗

Incidence and outcomes of lasik with diffuse lamellar keratitis treated with topical and oral corticosteroids.

PURPOSE: To analyze the incidence and clinical outcomes of patients developing diffuse lamellar keratitis (DLK) after laser in situ keratomileusis (LASIK) treated with topical and oral corticosteroids. SETTING: Oregon Eye Institute, Eugene, Oregon, USA. METHODS: A retrospective analysis of the last consecutive 1000 LASIK cases was performed. Eyes developing stage 3 DLK or at risk for progressing to stage 3 were treated with a combination of high-dose prednisolone acetate 1% and oral prednisone and evaluated for corneal scarring, loss of best spectacle-corrected visual acuity (BSCVA), and deviation from the intended refractive outcome. RESULTS: Diffuse lamellar keratitis developed in 40 eyes (4%). It progressed to stage 3 in 7 eyes (17%). Oral and topical steroids were used in 22 eyes (55%). The mean variation from the desired refractive outcome was 0.14 diopter +/- 0.53 (SD). There were no instances of corneal scarring or permanent loss of BSCVA. No eye had interface irrigation. CONCLUSIONS: Treatment of severe DLK with high-dose topical and oral corticosteroids produced excellent results without flap lifting and interface irrigation.

Administration, Oral↗

Bilateral nongranulomatous anterior uveitis associated with bimatoprost.

A 72-year-old man with long-standing bilateral glaucoma became refractory to levobunolol ophthalmic solution therapy after many years. Brimonidine was prescribed, but the patient developed a hypersensitivity several months later that was treated with loteprednol ophthalmic suspension. Bimatoprost was initiated 2 weeks later. Within an hour of the first dose of bimatoprost, the patient reported eye pain and photophobia that remained unresolved the following day. Examination revealed acute bilateral nongranulomatous anterior uveitis that was effectively treated with loteprednol. While observations in human and animal models suggest an association between certain prostaglandin-like agents and intraocular inflammation, this report is one of the first to suggest a link between bimatoprost and intraocular inflammatory reaction.

Aged↗

Refractive lens exchange with a multifocal intraocular lens.

Refractive lens exchange with a multifocal intraocular lens is becoming a more popular method of refractive surgery in the presbyopic patient. The limitations of keratorefractive surgery have led to a resurgence of lens exchange surgery for patients with prescriptions outside the limits of corneal refractive procedures, in addition to patients with routine refractive errors requesting a surgical procedure to achieve emmetropia and also address presbyopia. Side effects of multifocal technology including unwanted photic phenomena and deterioration in contrast sensitivity are being further defined and evaluated to better assess the effects of these intraocular lenses on functional vision and patient satisfaction. Attention to detail in regards to proper patient selection, preoperative measurements, intraoperative technique, and postoperative management will ultimately result in excellent outcomes and improved patient acceptance of this effective technique.

Device Removal↗

Suture fixation of a foldable acrylic intraocular lens for ectopia lentis.

A 5-year-old boy with severe ectopia lentis had bilateral lensectomy and suture fixation of a foldable acrylic intraocular lens (IOL) through a 3.0 mm clear corneal incision. Sodium hyaluronate (Healon GV) enhanced stability of the crystalline lens during aspiration and maintenance of the anterior chamber during passage of the needles through the ciliary sulcus. The haptic design of the single-piece AcrySof (Alcon) IOL permitted secure fixation of the suture to the haptic. The patient experienced rapid visual rehabilitation, achieving an uncorrected visual acuity of 20/40 in both eyes.

Acrylic Resins↗

Stabilization of flat anterior chamber after trabeculectomy with Healon5.

A 64-year-old phakic patient had a trabeculectomy complicated by complete shallowing of the anterior chamber 10 days postoperatively. Despite repair of a conjunctival wound dehiscence and reformation of the anterior chamber with sodium hyaluronate 3.0%-chondroitin sulfate 4.0% (Viscoat), he had a flat anterior chamber again the following day with 360 degrees of pupillary synechias and lens-to-cornea touch. Sodium hyaluronate 2.3% (Healon5) instilled through a paracentesis at the slitlamp lysed the synechias, stabilized the anterior chamber, facilitated filtration, and prevented complications from hypotony. The unique properties of Healon5 allowed for a conservative and less invasive approach in the management of this particular complication.

Anterior Chamber↗

Refractive lens exchange with the array multifocal intraocular lens.

PURPOSE: To study the safety and efficacy of refractive lens exchange as a refractive surgery modality in the presbyopic population. SETTING: Oregon Eye Institute, Eugene, Oregon, USA. METHODS: This retrospective review of patient charts included patient selection, preoperative evaluation, management of astigmatism, surgical technique, postoperative visual outcome, and complications. The study included 68 eyes comprising 32 bilateral and 4 unilateral refractive lens exchanges. RESULTS: All patients having bilateral refractive lens exchange achieved an uncorrected binocular visual acuity of 20/40 and J5 or better 1 to 3 months postoperatively. More than 90% achieved an uncorrected binocular visual acuity of 20/30 and J4 and nearly 60%, of 20/25 and J3. CONCLUSION: Refractive lens exchange was a safe and effective refractive surgery modality in presbyopic patients.

Aged↗

Immersion A-scan compared with partial coherence interferometry: outcomes analysis.

PURPOSE: To compare 2 methods of axial length measurement, immersion ultrasonography and partial coherence interferometry, and to elucidate surgical outcomes based on immersion measurements. SETTING: Oregon Eye Institute, Eugene, Oregon, USA. METHODS: Axial length measurements in 50 cataractous eyes were obtained by optical biometry (IOLMaster, Zeiss Humphrey Systems) and immersion ultrasound (Axis II, Quantel Medical), and the results were compared. Intraocular lens (IOL) power calculations in the same eyes after cataract extraction and posterior chamber IOL implantation were evaluated retrospectively based on the postoperative spherical equivalent prediction error. RESULTS: Immersion ultrasonography and partial coherence interferometry measurements correlated in a highly positive manner (correlation coefficient = 0.996). Outcomes analysis demonstrated 92.0% of eyes were within +/-0.5 diopter of emmetropia based on immersion axial length measurements. CONCLUSION: Immersion ultrasonography provided highly accurate axial length measurements and permitted highly accurate IOL power calculations.

Biometry↗

Comparison of sonic and ultrasonic phacoemulsification using the Staar Sonic Wave system.

PURPOSE: To compare the performance of sonic phacoemulsification with that of ultrasonic phacoemulsification in regard to 1-day postoperative visual acuity, corneal edema, and procedure efficiency. SETTING: Oregon Eye Institute, Eugene, Oregon, USA. METHODS: This prospective nonrandomized study comprised 86 eyes with mild to moderate nuclear sclerotic cataract. Forty-three eyes had sonic and 43 ultrasonic phacoemulsification using the Staar Sonic Wave phacoemulsification system. The mean age was 76 years in the ultrasonic group and 71 years in the sonic group. The mean nuclear sclerosis was 2.0+ in the sonic group and 1.9+ in the ultrasonic group. Patient age, lens density, postoperative corneal edema, 1-day postoperative uncorrected visual acuity (UCVA), and the percentage of eyes with a visual acuity of 20/40 or better were determined. In addition, the mean ultrasonic and sonic times, mean percentage phaco power, and mean effective phaco time (EPT) were calculated in each group. RESULTS: Both groups had a 5% incidence of trace corneal edema. The mean UCVA was 20/41 in the ultrasonic group and 20/42 in the sonic group. Seventy-nine percent of eyes in the ultrasonic group and 74% in the sonic group had a UCVA of 20/40. The mean percentage phaco power was 7.2% and 7.6% in the ultrasonic group and sonic group, respectively. The mean EPT was low in both groups, 4.0 and 2.9 seconds, respectively. CONCLUSION: Sonic technology yielded outcomes similar to those of ultrasonic phacoemulsification with respect to postoperative visual acuity and corneal edema in patients with average density nuclear sclerotic cataract.

Corneal Edema↗