PubMed Health⌕ Search

Biomedical subjects

I J Murray

Publications and source records attributed to I J Murray.

At least 19 recordsLinked to original sources

Almost complete colour constancy achieved with full-field adaptation.

A successive asymmetric colour-matching task was used to study the changes in colour appearance of simulated Munsell samples. Colour shifts were induced with two Planckian illuminants, standard illuminant A (u'=0.256, v'=0.524) and illuminant S (u'=0.174, v'=0.392). Measurements were conducted with a 20 degrees field and a 120 degrees field. Adaptation period varied from 1 to 30s with the smaller field and from 1 to 60s with the larger field. Colour shifts were specified in terms of a modified Brunswik ratio (BR). Higher values of BR were associated with longer adaptation periods but only when the larger background was used. Supplementary experiments showed that the changes in colour appearance were related to a slight shift in the perceived colour of the background. The timing of the colour shifts are modelled in terms of cone opponent responses. High values of BR correspond to almost complete von Kries adaptation in all three cone types.

Adaptation, Ocular↗

The dazzle reflex: electrophysiological signals from ocular muscles reveal strong binocular summation effects.

Under dark adapted or dim conditions the mammalian visual system is carefully programmed to respond rapidly to the sudden onset of bright lights. This response, called the dazzle reflex, is controlled from sub-cortical structures of the brain. It is known anecdotally that exposure to a bright light when dark adapted induces an instinctive closure of one eye to reduce the pain associated with dazzle. This binocular summation of the dazzle response has not previously been reported. The dazzle reflex can be measured in human subjects by recording the electrical activity from surface electrodes located near the muscles around the eye. In this paper we report an investigation of the apparent binocular summation of the dazzle reflex using this technique. The data reveal a clear difference between monocular and binocular stimulation, with the binocular response being much larger than the monocular response. Furthermore this monocular/binocular difference arises only if the stimulus duration is longer than approximately 1 s. These observations are interpreted in terms of the known physiology of blink mechanisms.

Adult↗

Road traffic casualties: understanding the night-time death toll.

A disproportionate number of fatal injuries occur after dark. The paper presents some statistics of road traffic injuries in a novel way which suggests that low luminance plays a major role in this effect. A sound physiological explanation for this is advanced based on the poor temporal characteristics of rod photoreceptors. It is argued that processing information based on low luminance, low contrast targets is much slower than that for high contrast bright targets. To test the idea, simple visual reaction times were measured under typical low visibility conditions encountered on non-lit roads and were found to be substantially longer than under optimal conditions. It is shown that longer reaction times translate into significantly increased stopping distances. This important point has received insufficient attention in the road safety literature, by the Highways Agency, the police, injury prevention officials, and the UK Highway Code.

Accidents, Traffic↗

Cone contrast computations: physical versus perceived background and colour constancy.

The light reflected from an object depends both on the object's surface and on the illuminant. Visual systems attempt to resolve this intrinsic ambiguity by comparing the light reflected from the object with respect to the background by computing the difference between the object-background light sampled by three cones. The cone-contrasts for the sample-background stimulus under the test illumination should correspond to the cone-contrasts for samples matched in appearance under the standard background (C). The validity of this cone-contrast rule (Whittle, 2003) and its possible link with stability of perceived colour was studied here using six test illuminants. A successive asymmetric colour-matching task with 40 simulated Munsell samples (value 7, chroma 4) on a neutral background (N7) was used. The subject adjusted the sample under standard illuminant C to match the colour appearance of the test sample under one of the test illuminants. Brunswik Ratio (BR) was used as an index of stability of colour appearance. When computed with respect to the reference illuminant C, the cone contrast rule was violated (particularly for S-cone-contrast). However, if a new reference point based on the perceived colour of the neutral background under the test illumination was used, the cone contrast rule applied. That is, when cone contrasts of the matching samples are computed with respect to this perceived background, they correspond to cone contrasts of the test stimuli. This represents a form of discounting the illuminant for the purpose of determining an object's cone-contrast against the background, which does not vary with background illumination. These cone contrasts, however, do not provide any information about the colour appearance of objects under particular viewing conditions, unless calibrated against a standard by allowing subjects to learn particular colours.

Adaptation, Ocular↗

Contrast coding and magno/parvo segregation revealed in reaction time studies.

Reaction times (RTs) are obtained for a wide range of contrasts of vertical sinusoidal gratings. The data are plotted as a function of the reciprocal of contrast. In some conditions, a single linear function accounts for the data. In others a clear bi-linear function is obtained. The low and high contrast regions of the function are interpreted as representing magno and parvo activity, respectively. RT-based supra-threshold sensitivity functions are obtained for different luminances, stimulus durations and eccentricities and these are compared with conventional threshold-based sensitivities to establish the extent to which RTs and contrast sensitivity are constrained by the same sensory processes.

Color Perception↗

Scalp VEPs and intra-cortical responses to chromatic and achromatic stimuli in primates.

We propose asimple method of monitoring separate visual pathways inlightly sedated monkeys using chromatic and achromatic gratings of low contrast, which are known to activate predominantly either parvo- or magno-systems. The scalp Visual Evoked Potentials (VEPs) are compared with simultaneously recorded intra-cortical VEPs which in turn are compared with multi-unit and single-unit responses. At isoluminance, the onset of low contrast, coarse chromatic square wave spatial profile gratings generates negative scalp VEPs which exhibit properties consistent with the activation of sustained, parvocellular-chromatic mechanisms (e.g. low-pass spatio-temporal characteristics). In monkeys, most components of chromatic onset VEPs have latencies comparable to neuronal activity within the supragranular layers of V1. Corresponding coarse achromatic gratings elicit positive VEPs which exhibit properties consistent with the activation of transient-type magnocellular mechanisms (e.g. temporal tuning to higher temporal frequencies) and which have a more complex morphology. Achromatic onset VEPs may contain early components of similar timing to activity recorded in monkey V1, but later components cannot be related to V1 generators; other sources are not known. Achromatic reversal VEPs are similar to achromatic onset, chromatic reversal and both chromatic and achromatic offset VEPs and all differ from chromatic onset VEPs. It is observed that early components of scalp-recorded chromatic-onset VEPs are related in time to some intra-cortical potentials. These VEPs are generated by low spatial frequencies and have low pass temporal characteristics. Other scalp potentials, apparently unrelated to V1 field potential activity must be generated by other sources such as extra-striate areas.

Animals↗

Reaction times as an index of visual conspicuity when driving at night.

Conspicuity refers to the visibility of objects that are either close to threshold or viewed in a cluttered environment. Conventional, threshold-based tests of vision are unlikely to be related to target visibility, because visual systems behave differently under supra-threshold and close-to-threshold conditions, or when low luminance levels are used. In these experiments, Reaction Times (RTs) are tested under a wide range of contrasts, luminances and spatial frequencies commonly encountered in the real world. We show that RTs are closely related to sensitivity and can therefore provide a method of measuring supra-threshold visual performance. The data are interpreted in terms of visual performance when driving, where a reduction in target visibility leads to increases in processing time.

Accidents, Traffic↗

Red--green and blue--yellow mechanisms are matched in sensitivity for temporal and spatial modulation.

The spatial and temporal properties of human colour vision are examined using isoluminant, red--green and blue--yellow tritanopic gratings. Chromatic sensitivity is found to be low-pass as a function of both spatial and temporal frequency along all the chromatic axes investigated, including the tritanopic confusion lines employed to examine the properties of the S-cone driven mechanism. Comparison of sensitivity to on-off and contrast reversing stimuli indicates that transient mechanisms contribute to the detection of red--green patterns but that the detection of S-cone specific patterns is governed by sustained mechanisms. By compensating for transient contributions to red--green sensitivity, it is shown that sensitivity of chromatic mechanisms dominated by L- and M-cone input are closely matched to those with S-cone input.

Color Perception↗

Raised visual detection thresholds depend on the level of complexity of cognitive foveal loading.

The objective of the study was to measure the interactions between visual thresholds for a simple light (the secondary task) presented peripherally and a simultaneously performed cognitive task (the primary task) presented foveally The primary task was highly visible but varied according to its cognitive complexity. Interactions between the tasks were determined by measuring detection thresholds for the peripheral task and accuracy of performance of the foveal task. Effects were measured for 5, 10, 20, and 30 deg eccentricity of the peripherally presented light and for three levels of cognitive complexity. Mesopic conditions (0.5 lx) were used. As expected, the concurrent presentation of the foveal cognitive task reduced peripheral sensitivity. Moreover, performance of the foveal task was adversely affected when conducting the peripheral task. Performance on both tasks was reduced as the level of complexity of the cognitive task increased. There were qualitative differences in task interactions between the central 10 deg and at greater eccentricities. Within 10 deg there was a disproportionate effect of eccentricity, previously interpreted as the 'tunnel-vision' model of visual field narrowing. Interactions outside 10 deg were less affected by eccentricity. These results are discussed in terms of the known neurophysiological characteristics of the primary visual pathway.

Adult↗

Macular pigment and risk for age-related macular degeneration in subjects from a Northern European population.

PURPOSE: Age and advanced disease in the fellow eye are the two most important risk factors for age-related macular degeneration (AMD). In this study, the authors investigated the relationship between these variables and the optical density of macular pigment (MP) in a group of subjects from a northern European population. METHODS: The optical density of MP was measured psychophysically in 46 subjects ranging in age from 21 to 81 years with healthy maculae and in 9 healthy eyes known to be at high-risk of AMD because of advanced disease in the fellow eye. Each eye in the latter group was matched with a control eye on the basis of variables believed to be associated with the optical density of MP (iris color, gender, smoking habits, age, and lens density). RESULTS: There was an age-related decline in the optical density of macular pigment among volunteers with no ocular disease (right eye: r(2) = 0.29, P = 0.0006; left eye: r(2) = 0.29, P < 0.0001). Healthy eyes predisposed to AMD had significantly less MP than healthy eyes at no such risk (Wilcoxon's signed rank test: P = 0.015). CONCLUSIONS: The two most important risk factors for AMD are associated with a relative absence of MP. These findings are consistent with the hypothesis that supplemental lutein and zeaxanthin may delay, avert, or modify the course of this disease.

Adult↗

Neurophysiological interpretation of human visual reaction times: effect of contrast, spatial frequency and luminance.

Neurophysiological studies have demonstrated that in primates Magno and Parvo neurons have distinct contrast gain properties. Reaction Times (RTs) can be used to study supra-threshold contrast coding in humans over the same range of stimulus parameters. RTs to achromatic sinusoidal gratings were measured for a range of spatial frequencies (0.49-17.7 c/degree), stimulus luminances (0.005-20 cd/m2) and contrasts (from threshold to 0.5). The stimuli subtended an angle of 7.2 degrees at a viewing distance of 114 cm. RTs exhibit a linear relationship when plotted against the reciprocal of suprathreshold contrast. The slope of these functions reveals how contrast is linked to RT and can, therefore, be referred to as the RT-contrast factor with units of msec x contrast. A general equation is derived which accounts for all stimulus combinations. RT-based contrast functions resemble closely those obtained neurophysiologically for Magno (M) and Parvo (P) cells. Furthermore, the RT equivalent of contrast gain exhibits qualitatively similar gain characteristics to these neurons for a wide range of luminances and spatial frequencies. Our data support the notion that the sensory component of RTs is limited by the properties of pre-cortical neurons.

Adult↗

Macular pigment optical density measurement: a novel compact instrument.

A compact device to derive the optical density of human macular pigment (MP) using heterochromatic flicker photometry is described. The validity of the system is assessed by measuring the optical density spectra of MP in 12 healthy subjects and comparing this with well-established previously published values. The mean spectral absorbance characteristics of MP across subjects corresponds well with accepted values. As reported in other studies, our measurements show a wide variation of MP optical densities between individuals. In our technique within-subject variability is low; standard deviations are between 0.025 and 0.15 in most cases. The overall optical density of MP ranged from 0.08 to 0.84 with a mean of 0.496 and standard deviation of 0.257 at 460 nm. The stimulus size was 0.95 degrees. The unique feature of the technique is that it allows free viewing (not Maxwellian View) of the stimulus, it can be conducted easily and quickly and does not need frequent re-calibration.

Humans↗

Spatio-temporal tuning of VEPs: effect of mode of stimulation.

The spatial tuning function of the 8 Hz reversal Visual Evoked Potential (VEP) is frequently bimodal. This amplitude 'notch' largely disappears with 16 Hz pattern onset-offset (on-off) stimulation. To investigate the effect of temporal frequency on this phenomenon, we tested seven subjects using a range of rates centred on 8 Hz (reversal) and 16 Hz (on-off). With reversal, a deep notch was present at all temporal frequencies. A much shallower notch was evident with on-off. The on-off and reversal functions differed only in their low spatial frequency branches (below 4.5 c deg-1) where, as temporal frequency decreased, the reversal response was reduced by 50%, whilst the on-off responses doubled in amplitude. Thus, although they behave differently with on-off and reversal, multiple spatial frequency mechanisms are evident with both forms of stimulation.

Contrast Sensitivity↗

Theoretical and practical performance of a concentric bifocal intraocular implant lens.

Some results from a survey of 43 patients who had a monofocal intra-ocular-lens (IOL) in one eye and a concentric bifocal intra-ocular-lens in the fellow eye are reported. Twenty patients with 6/9 or better post-operative visual acuity in both eyes, participated in the main part of the study. Optical transfer functions for the bifocal lens showed that, compared to an optimal single-vision correction, there is a 50% contrast degradation of the distance retinal image across all spatial frequencies above around 3 c/deg. For the patients in the main study, there was a close correspondence between practical measurement of contrast sensitivity and the theoretical predictions of the modulation transfer functions. Measuring contrast sensitivity proved an effective means of assessing misalignment of the bifocal IOLs.

Aged↗

Scattering properties of Bagolini lenses and their effects on spatial vision.

The effect of a Bagolini lens on spatial vision was investigated by studying its far-field diffraction pattern as produced by a coherent beam of laser light, and its effect on the contrast sensitivity function (CSF) in human subjects. For lenses of the main type studied, which were crossed by a series of slightly-irregular striated bands, each consisting of fine, parallel, etched lines of various widths and separations, the diffraction pattern consisted of undiffracted light giving a bright central spot and wide-angle, diffracted light giving a dim streak. The latter was due to the sum of the diffraction patterns associated by the irregular fine etched lines. The streak produced by a single striated band was modulated by a series of regular maxima and minima related to the width of the band. Analysis of this pattern gave the width of the band as 0.6 mm, in close agreement with direct microscopical measurements. When four bands were illuminated by a beam of about 3 mm diameter, similar to the diameter of the photopic pupil, the diffraction pattern showed no obvious maxima and minima, due to irregularity in the width and separation of the bands. The central spot contained more than 90% of the total light in the diffraction pattern. Thus the Bagolini lens, with its relatively weak far-field diffraction pattern lacking regular maxima and minima when areas > or = 3 mm in diameter were used, was expected to have only a small effect on the apparent contrast of the targets in CSF experiments. This was confirmed by the measurements: Bagolini lenses showed no significant effect on either the monocular or binocular CSF. Further similar measurements with lenses of slightly different design from another manufacturer confirmed these findings. Therefore Bagolini lenses do not disrupt vision when they are used to determine the presence of suppression and anomalous retinal correspondence.

Contrast Sensitivity↗

Spectral sensitivity in patients with dysthyroid eye disease.

The majority of patients with dysthyroid eye disease have an acquired colour vision defect. However, no psychophysical investigation of selective damage to colour or flicker pathways has been carried out. In order to clarify the nature of the visual pathology, we have used a psychophysical technique (spectral sensitivity) to selectively stimulate the chromatic and achromatic mechanisms. Spectral spots of size 1 degree presented at a rate of 1 Hz on a bright 1000 td white background are detected by the chromatic mechanism but a rate of 25 Hz reveals the achromatic mechanism. Fifteen patients (28 eyes) between the ages of 50-70 years were tested. The study showed that all patients had reduced spectral sensitivity, either 1 Hz, 25 Hz or both. The patients with reduced 1 Hz or 25 Hz spectral sensitivity only had a shorter systemic and ocular duration of the condition, had no proptosis, normal intraocular pressures in primary gaze, slightly higher intraocular pressures on upgaze, normal visual field plots and FM 100-Hue error scores higher than the normal age-matched values. The patients with reduced both 1 Hz and 25 Hz spectral sensitivities had a longer systemic and ocular duration of the condition, had proptosis, normal intraocular pressures in primary position, higher intraocular pressures on upgaze and higher FM 100-Hue error scores than the age-matched normals and those in Groups 1 and 2. A total of 50% of patients in Group 3 had defective visual field plots. These data suggest that there is a damage of the large achromatic fibres and small chromatic fibres in dysthyroid eye disease. The mechanism of the damage could be one of ischaemic or mechanical or both.

Aged↗

Pattern ERGs from isoluminant gratings; poor selectivity compared with VEPS.

The PERGs elicited by low contrast achromatic (luminance-modulated) and chromatic (isoluminant) gratings were studied as a function of the presentation mode (rapid onset, offset, reversal), departure from isoluminance, contrast and spatial frequency; predominantly phasic-type responses were found in all cases. We propose that the PERGs for low and moderate contrast, achromatic and chromatic grating stimuli, are generated by non-linear, transient retinal cells of the magno-system. Parvo retinal cells seem to contribute to the response only at higher chromatic contrasts. The transient nature of the PERG obtained from isoluminant gratings makes it doubtful that these signals represent the activity of colour-related processes.

Adult↗