Objective measurement of contrast sensitivity and visual acuity with the steady-state visual evoked potential.

Since the appearance of Campbell and Maffei's and Harter and White's reports it has been well established that the visual evoked potential (VEP) can be used to predict psychophysical contrast sensitivity and visual acuity and is thus suited as an objective technique to assess these fundamental aspects of vision. Nevertheless, the technique has not become a standard diagnostic tool, being too time-consuming to apply and suffering from variable reliability under pathological visual conditions. In addition, there are problems of reliability in normal subjects. By using an unconventional stimulus--temporally sinusoidal 16-Hz on-off modulation of sinewave gratings--we demonstrated that these problems can be alleviated in normal subjects. This stimulus avoids the low signals in the visible range that frequently occur with conventional pattern-reversal stimuli, it leads to high correspondence between normal observers, and it is much faster to apply than are transient VEPs. Initial applications of this stimulus to amblyopes yielded promising results. The steady-state VEP could consequently turn into a viable diagnostic procedure in disturbances of visual contrast perception.

Contrast Sensitivity↗

Visual safety of quartz linear lamps.

A quartz linear lamp (QLL) is a compact infra-red (i.r.) heating lamp. It consists of a tungsten filament in a quartz envelope, which for space heating purposes is surrounded by a ruby coloured filter. The filament runs at about 2400 K and produces i.r. radiation with a peak output at 1200 nm. The lamps are widely used for space heating and are normally fitted with a parabolic reflector. There are no statutory criteria for potential visual hazards resulting from the use of such lamps in the U.K. The ACGIH has produced a provisional set of rules on light and near i.r. This paper reviews potential hazards to the eye in the context of the ACGIH rules and the output of QLL heaters. The heaters produce no u.v. or blue light hazards. The brightness and heat of the lamp is sufficient to produce an aversion response which will prevent retinal thermal damage from inadvertent viewing. The probability of retinal thermal injury from an i.r.-A image focused on the retina is examined and it is shown that there is no risk at normal viewing distances. To prevent any risk of cataractogenesis, the rules provide for an upper limit of irradiance (TLV) at the eye of 100 W m-2 in the i.r.-A band; the paper examines the potential hazard from longer wavelengths and concludes that they do not present a hazard with this type of heating. The conclusion is that QLL heaters used for space heating in accordance with manufacturer's instructions present no hazard to the eye.

Eye↗

The visual defect in multiple sclerosis and optic neuritis. A combined psychophysical and electrophysiological investigation.

Chromatic and achromatic visual function were investigated using psychophysical and evoked potential techniques in 32 patients with multiple sclerosis (MS) or optic neuritis. There was no evidence for either chromatic or achromatic vision being selectively damaged. There was, however, some evidence that demyelination of the optic nerve causes a visual defect in which the transmission of high temporal frequencies is imparied. In some patients either a red or blue deficit was evident, but overall there was no evidence of a wavelength specific colour vision defect in our patient group. Reduction of chromatic sensitivity as determined psychophysically had a statistically significant correlation with the amplitude and latency of the chromatic visual evoked potential.

Adult↗

Visual changes mediated by beer in retrobulbar neuritis--an investigative case report.

A patient with established retrobulbar neuritis and Uhthoff's phenomenon who claimed that his visual acuity improved after drinking beer was assessed by detailed quantitative psychophysical tests. Studies of electrophysiological responses and biochemical levels of blood serum before and after drinking on several occasions were also made. The results of tests of contrast sensitivity, spectral sensitivity, flicker sensitivity, and visually evoked potential confirmed his observation. Some mechanisms for this phenomenon are considered.

Adult↗

Movement detection and spatial phase.

Contrast thresholds for the detection of movement are determined when a sinusoidal grating pattern is shifted in spatial phase. "True" contrast reversal (180 degrees phase shift) is compared with smaller phase shifts for a range of spatial frequencies. An unexpected increase in movement sensitivity is revealed for intermediate spatial frequencies. This effect is confined to those spatial frequencies where interaction between pattern and movement detectors occurs.

Humans↗

A pilot study on the use of visual field expanders.

The nature and magnitude of the visual difficulties of five volunteer patients with severely contracted visual field and high visual acuities was investigated by several techniques. These comprised a questionnaire providing a quantitative score of visual impairment, a specially devised visual search task, and an arbitrary method of estimating visual efficiency. Many aspects of visual impairment resulting from contract visual fields were revealed and discussed. Performance scores on the search task indicated that the field expander would probably be useful to a small number of cases for continuous wear, usually as a binocular bioptic system. Other cases might benefit from a clip-on or hand-held device for occasional use. Methods of manufacture and dispensing and difficulty in locating suitable patients were the major limiting factors in this study. The methods of assessment, and the optical system described in this study are worthy of further investigation and development for trial on a larger number of patients.

Eyeglasses↗

Amplitude and phase variations of harmonic components in human achromatic and chromatic visual evoked potentials.

Occipital visual evoked potentials (VEPs) were recorded in response to low-contrast, low spatial-frequency chromatic, and achromatic gratings. Fast Fourier Transform (FFT) and time-domain analysis were used to reveal differences in harmonic content and amplitude of chromatic and achromatic response components over a wide range of temporal frequencies. The chromatic ON/OFF VEP is dominated by the fundamental component indicating that onset and offset responses are different. This type of response is typical of neurons with sustained type response characteristics. Conversely, the achromatic onset VEP contains a predominant second harmonic component in addition to the fundamental. This similarity between onset and offset responses suggests that transient mechanisms are responsible for the generation of achromatic components. Frequency analysis of VEPs elicited by phase-reversing stimuli reveals that all of the response energy is concentrated at the second harmonic of the stimulating frequency. The magnitude of the second harmonic component is maximal for achromatic stimuli and undergoes a distinct minimum for isoluminant, chromatic stimuli. This behavior indicates that under the stimulus conditions used, magnocellular neurons with transient characteristics dominate the reversal VEP.

Adult↗

Photoreceptor topography and cone-specific electroretinograms.

It is implicit in many cone-specific ERG studies that the amplitude is proportional to the numbers of cones stimulated. The objective of these experiments was to test this idea by comparing ERGs obtained from different areas of the retina with histological data on cone-density distributions. The histology (Curcio et al., 1990) shows that the cumulative number of cones in the human retina increases exponentially with stimulus diameter between 0- and 40-deg eccentricity. L-, M-, and (L+M) cone-driven 30-Hz ERGs were obtained from a series of stimuli with one of the following configurations: (1) Circular stimuli of different angular subtense up to 70-deg diameter. (2) Annuli with 70-deg outer diameter but variable inner diameter. (3) Annuli of constant area but increasing eccentricity. Cone contrasts were equalized for each stimulus condition. The modulated and nonmodulated regions of the screen had the same mean hue and luminance. The data suggest that the L+M cone ERG amplitude increases with stimulus diameter in direct proportion to the estimated number of cones stimulated. Furthermore, the total L+M responses appear to be predicted from individual L and M responses by simple linear summation for both the disc and annular stimuli.

Electroretinography↗

Effect of foveal tritanopia on reaction times to chromatic stimuli.

To investigate the effect of foveal inhomogeneities on sensitivity to chromatic stimuli, we measured simple reaction times (RTs) and detection thresholds to temporally and spatially blurred isoluminant stimuli at retinal eccentricities from 0 deg to 8 deg. Three color-normal subjects participated. Contrast gain was derived from the slope of the RT versus contrast function. With a Gaussian spatial distribution (S.D. = 0.5 deg) and modulation between white (CIE x, y, L = 0.31, 0.316, 12.5 cd x m(-2)) and blue (MBDKL 90 deg), gain was maximal at about 2-deg eccentricity and declined by approximately 1 log unit towards the center and the periphery. The red (0 deg) and green (180 deg) cardinal axes showed maximum gain in the center, whilst the yellow (270 deg) data were intermediate. Although the spatial extent of the Gaussian spot was much larger than the S-cone free zone, we wished to determine whether foveal tritanopia was responsible for the marked drop in sensitivity to the 90-deg stimulus. To align the color vector along a tritan line, we used a smaller disk (0.3 deg) with a blurred edge and measured detection threshold, rotating the vector until minimum central sensitivity was obtained. Other workers have used transient tritanopia or minimally distinct border to similar effect. By repeating this at different locations in color space, a group of vectors were obtained. These converged near to the S-cone co-punctal point, evidence that they lay along tritan confusion lines. These threshold findings were then confirmed using the RT-derived contrast gain function. The tritan vectors were less pronounced as stimulus size increased. With the vector optimized to produce foveal tritanopia, the RT gain versus eccentricity functions for the 90-deg and 270-deg stimuli both fell markedly in the center and periphery, and sensitivity peaked at about 3-deg eccentricity. There are some similarities between these findings and the underlying photoreceptor distributions. As a result, there is a greater difference in gain between red-green and blue-yellow systems in the center than in the near periphery. We conclude that the RT versus contrast function is a sensitive index of foveal opponency.

Color Perception↗

Cone contrasts do not predict color constancy.

A successive, asymmetric color-matching paradigm was used to investigate the link between cone contrast and the stability of perceived colors. We measured the perceived color shifts of 10 Munsell samples, induced by test illuminant A, simulated in u'v' color space. The capacity of the visual system to resist these shifts, otherwise known as color constancy, is measured in terms of the Brunswik ratio, BR. Cone contrasts are calculated with respect to either the physical or perceived background. Subjective cone contrasts show a better fit to the von Kries law than those based on the physical background. Complete cone adaptation occurs when color constancy is high. However we show conditions where cone adaptation seems complete but color constancy is poor.

Color↗

Cone opponency in the near peripheral retina.

Changes of color perception in the peripheral field are measured using an asymmetric simultaneous matching paradigm. The data confirm previous observations in that saturation changes can be neutralized if the test target is increased in size. However, this compensation does not apply to hue shifts. We show that some hues remain unchanged with eccentricity whereas others exhibit substantial changes. Here the color shifts are plotted in terms of a second-stage cone opponent model. The data suggest that the S-L+M channel is more robust to increasing eccentricity than the L-M channel. Observations are interpreted in terms of the known underlying morphological and physiological differences in these channels.

Adaptation, Ocular↗