PubMed Health⌕ Search

Biomedical subjects

Isiah M Warner

Publications and source records attributed to Isiah M Warner.

At least 19 recordsLinked to original sources

Understanding chiral molecular micellar separations using steady-state fluorescence anisotropy, capillary electrophoresis, and NMR.

Chiral separations employing four diastereomers of poly sodium N-undecanoyl leucylvalinate (p-SULV) as chiral selectors are probed by use of MEKC, steady-state fluorescence anisotropy, and NMR. By employing diastereomers and thus altering the stereochemistry of a single amino acid in a systematic way, one may control the enantiorecognition ability of the chiral selector. As a result, one can gain a better understanding of the mechanisms of chiral recognition for the two classes of neutral or anionic chiral analytes studied. Evaluation of the chiral interactions leading to chiral separations confirmed our earlier observation of a strong relationship between the selectivity (alpha) observed using a chromatographic separation technique (MEKC) and that determined from the spectroscopic parameter, beta. A linear alpha versus beta relationship was observed for the molecular micelle p-(L)-SULV with all eight analytes included in this study. However, as we earlier predicted, different groups of analytes had different slopes, i.e., values of m, suggesting different chiral separation mechanisms. Evaluation of the data allowed a grouping of the analytes according to the primary site of chiral interaction with the leucine or valine moiety of molecular micelle chiral headgroup.

Anisotropy↗

An organic white light-emitting fluorophore.

The synthesis of new benzo[a]- and [b]xanthene dye frameworks is described. A unique benzo[a]xanthene, seminaphtho[a]fluorone (SNAFR-1), is studied in a variety of media. The optimization of solution parameters and excitation wavelengths allows SNAFR-1 to display red, green, and blue emission bands of approximately equal intensities and also to produce white light. Ratiometric red (anion) and green (neutral) emissions are observed upon varying solution pH. A pH-independent violet-blue emission band is due to the addition of nucleophiles to the benzylic carbon of SNAFR-1.

Cell Line↗

Stereochemical and regiochemical trends in the selective detection of saccharides.

Several discreet sugar-boronate complexes exist in solution. This is due to the complex equilibria between isomeric species of even the simplest monosaccharides. In the current investigation, we determine the regio- and stereochemical features of the various equilibrating sugar isomers that induce signal transduction in boronic acid chemosensors such as 1 as well as 2 and 3. We present a unique example of a chemosensor (1) that is selective for ribose, adenosine, nucleotides, nucleosides, and congeners. As a result of this study, we are able to predict and achieve selective fluorescence and colorimetric responses to specific disaccharides as a consequence of their terminal sugar residue linkage patterns and configurations. We also find that the combined use of chemosensors exhibiting complementary reactivities may be used cooperatively to obtain enhanced selectivity for ribose and rare saccharides.

Adenosine↗

Use of NMR binding interaction mapping techniques to examine interactions of chiral molecules with molecular micelles.

NMR spectroscopy was used to investigate the association of four chiral molecules with the molecular micelle poly(sodium N-undecanoyl-l-leucylvalinate) (poly(SULV)). Adding poly(SULV) to the background electrolyte in electrokinetic chromatography (EKC) allows enantiomeric resolution to be achieved because enantiomers interact differentially with the chiral centers on the micelle headgroups as they both move in the electric field. Pulsed field gradient diffusion experiments were used to measure molecular micelle association constants for enantiomers of each analyte. These association constants were consistent with EKC elution order for the compounds 1,1'-binaphthyl-2,2'-diyl hydrogen phosphate (BNP), 1,1'-bi-2-naphthol (BOH), and Troger's base. In addition, nuclear Overhauser enhancement spectroscopy, nuclear Overhauser effect difference, and intermolecular cross relaxation diffusion experiments were used to generate binding interaction maps for each chiral analyte. These maps showed that BNP and BOH inserted into the surfactant headgroup's major chiral groove and interacted predominately with the leucine chiral center. (+)-Troger's base was also found to insert into the major chiral groove. However, this compound instead interacted with the valine chiral atom. In diffusion experiments with long diffusion times, the linearized diffusion plots for each analyte-molecular micelle mixture showed curvature characteristic of intermolecular cross relaxation. The magnitude of this effect scaled linearly with the analytes' free energies of binding.

Chemistry, Physical↗

The use of poly(sodium N-undecanoyl-L-leucylvalinate), poly(sodium N-undecanoyl-L-leucinate) and poly(sodium N-undecanoyl-L-valinate) surfactants as chiral selectors for determination of enantiomeric composition of samples by multivariate regression modeling of fluorescence spectral data.

Steady-state fluorescence spectroscopy was employed to investigate the use of chiral polymeric surfactants as chiral selectors in chiral analysis by multivariate regression modeling of spectral data. Partial-least-squares regression modeling (PLS-1) was used to correlate changes in the fluorescence spectral data of 1,1'-bi-2-naphthol (BOH), 1,1'-binaphthyl-2,2'-diamine (BNA), or 2,2,2-trifluoroanthrylethanol (TFA) in the presence of poly(sodium N-undecanoyl-L-leucylvalinate), poly(sodium N-undecanoyl-L-leucinate) or poly(sodium N-undecanoyl-L-valinate) as the enantiomeric composition of the chiral analytes was varied. The regression models produced from the spectral data were validated by determining the enantiomeric composition of independently prepared test solutions. The ability of the model to correctly predict the enantiomeric composition of future samples was evaluated using the root-mean-square percent-relative error (RMS%RE) of prediction. In terms of RMS%RE, the ability of the model to accurately predict the enantiomeric composition of future samples was dependent on the chiral analyte, the polymeric surfactant used, and the surfactant medium, and ranged between 1.57 and 6.10%. Chiral analyte concentrations as low as 5 x 10(-6) M were found to give regression models with good predictability.

Anthracenes↗

Lanthanide complexes as fluorescent indicators for neutral sugars and cancer biomarkers.

Simple water-soluble lanthanum and europium complexes are effective at detecting neutral sugars as well as glycolipids and phospholipids. In solutions at physiologically relevant pH the fluorescent lanthanum complex binds neutral sugars with apparent binding constants comparable to those of arylboronic acids. Interference from commonly occurring anions is minimal. The europium complex detects sialic acid-containing gangliosides at pH 7.0 over an asialoganglioside. This selectivity is attributed, in large part, to the cooperative complexation of the oligosaccharide and sialic acid residues to the metal center, based on analogous prior studies. In MeOH, lysophosphatidic acid (LPA), a biomarker for several pathological conditions including ovarian cancer, is selectively detected by the europium complex. LPA is also detected via a fluorescence increase in human plasma samples. The 2-sn-OH moiety of LPA plays a key role in promoting binding to the metal center. Other molecules found in common brain ganglioside and phospholipid extracts do not interfere in the ganglioside or LPA fluorescence assays.

Biomarkers, Tumor↗

Use of multivariate analysis for optimization of separation parameters and prediction of migration time, resolution, and resolution per unit time in micellar electrokinetic chromatography.

The optimization of separation parameters in chromatography for better separation and resolution of analytes continues to be a labor intensive procedure usually performed by a trial and error method. A multivariate analysis in the form of multilinear regression (MLR) is used to optimize separation parameters and predict the migration behavior, resolution, and resolution per unit time of achiral (4-chlorophenol, pentachlorophenol, clonazepam, and diazepam) and chiral (1,1'-binaphthyl 2,2'-dihydrogen phosphate (BNP), and 1,1'-bi-2-naphthol (BOH)) compounds in MEKC. Separations of achiral and chiral analytes were performed using an achiral (poly(sodium N-undecylenic sulfate)) molecular micelle and chiral (poly(sodium N-undecanoyl-L-leucylvalinate) or poly(sodium N-undecanoyl-L-isoleucylvalinate)) molecular micelle, respectively, at various operating temperatures, applied voltages, pH values, and molecular micelle concentrations in the BGE. The separation parameters were subsequently used as input variables for MLR models. The models were validated with independent samples. The root-mean-square percent relative error (RMS%RE) is used as a figure of merit for characterizing the performance of the migration time, resolution, and resolution per unit time models. The RMS%RE obtained for predicted migrated times, resolutions, and resolution per unit time of 4-chlorophenol, pentachlorophenol, clonazepam, diazepam, BNP, and BOH ranged between 8 and 19%. The same experimental procedure was used to optimize the separation parameters of six other chiral analytes of different compound class. The predicted migration times, resolutions, and resolution per unit time of the chiral as well as the achiral analytes compare favorably with the experimental migration times and resolutions, indicating versatility and wide applicability of the technique in MEKC.

Chromatography, Micellar Electrokinetic Capillary↗

Chiral separation of norlaudanosoline, laudanosoline, laudanosine, chlorthalidone, and three benzoin derivatives using amino acid based molecular micelles.

In this study, 18 polymeric single amino acid and dipeptide surfactants are examined, and their performances, in terms of enantioselectivity, are compared for norlaudanosoline, laudanosoline, laudanosine, chlorthalidone, benzoin, benzoin methyl, and benzoin ethyl enantiomers. Several aspects of amino acid-based polymeric surfactants including comparison of single amino acid versus dipeptide, amino acid order, steric effect, and effect of the position of the chiral center of dipeptide surfactants on the chiral selectivity of these optically active compounds are discussed.

Amino Acids↗

Detection of homocysteine and cysteine.

At elevated levels, homocysteine (Hcy, 1) is a risk factor for cardiovascular diseases, Alzheimer's disease, neural tube defects, and osteoporosis. Both 1 and cysteine (Cys, 3) are linked to neurotoxicity. The biochemical mechanisms by which 1 and 3 are involved in disease states are relatively unclear. Herein, we describe simple methods for detecting either Hcy or Cys in the visible spectral region with the highest selectivity reported to date without using biochemical techniques or preparative separations. Simple methods and readily available reagents allow for the detection of Cys and Hcy in the range of their physiologically relevant levels. New HPLC postcolumn detection methods for biological thiols are reported. The potential biomedical relevance of the chemical mechanisms involved in the detection of 1 is described.

Aldehydes↗

Monomeric and polymeric anionic gemini surfactants and mixed surfactant systems in micellar electrokinetic chromatography. Part I: characterization and application as novel pseudostationary phases.

Sodium di(undecenyl) tartarate monomer (SDUT), a vesicle-forming amphiphilic compound possessing two hydrophilic carboxylate head groups and two hydrophobic undecenyl chains gemini surfactant, was prepared and polymerized to form a polymeric gemini surfactant (i.e., poly-SDUT). These anionic surfactant systems with carboxylate (SDUT and poly-SDUT) and sulfate (sodium dodecyl sulfate, SDS) head groups as well as mixed surfactant systems (SDS/SDUT, SDS/poly-SDUT, and SDUT/poly-SDUT) were then applied as novel pseudostationary phases in micellar electrokinetic chromatography (MEKC). The SDUT and poly-SDUT were characterized using various analytical techniques. Retention factors of 36 benzene derivatives were calculated in 20 mM phosphate buffer of each surfactant system. The retention factor values of the test solutes show that there are distinctive selectivity differences between the surfactant systems. Solute-pseudostationary phase interactions in MEKC were also examined by determining the free energy of transfer of the substituted functional groups from the aqueous buffer phase into the pseudostationary phase.

Anions↗

Monomeric and polymeric anionic gemini surfactants and mixed surfactant systems in micellar electrokinetic chromatography. Part II: characterization of chemical selectivity using two linear solvation energy relationship models.

Sodium di(undecenyl) tartarate monomer (SDUT), a vesicle-forming amphiphilic compound possessing two hydrophilic carboxylate headgroups and two hydrophobic undecenyl chains, was prepared and polymerized to form a polymeric vesicle (i.e., poly-SDUT). The anionic surfactants of SDUT and poly-SDUT (carboxylate head group) and sodium dodecyl sulfate, SDS (sulfate head groups) as well as mixed surfactant systems (SDS/SDUT, SDS/poly-SDUT, and SDUT/poly-SDUT) were applied as pseudostationary phases in micellar electrokinetic chromatography (MEKC). Two linear solvation energy relationship (LSER) models, i.e., solvatochromic and solvation parameter models, were successfully applied to investigate the effect of the type and composition of pseudostationary phases on the retention mechanism and selectivity in MEKC. The solvatochromic and solvation parameter models were used to help understand the fundamental nature of the solute-pseudostationary phase interactions and to characterize the properties of the pseudostationary phases (e.g., solute size and hydrogen bond-accepting ability for all pseudostationary phases). The solute types were found to have a significant effect on the LSER system coefficients and on the predicted retention factors. Although both LSER models provide the same information, the solvation parameter model is found to provide much better results both statistically and chemically than the solvatochromic model.

Anions↗

Investigation of the stability of polyelectrolyte multilayer coatings in open-tubular capillary electrochromatography using laser scanning confocal microscopy.

A simple polyelectrolyte multilayer (PEM) coating procedure was used for the development of stable modified capillaries. PEM coatings were constructed in fused-silica capillaries using alternating rinses of cationic and anionic polyelectrolytes. The multilayer coatings investigated in this study consisted of two and twenty layer pairs, or bilayers. A bilayer is one layer of a cationic polymer and one layer of an anionic polymer. Poly(diallyldimethylammonium chloride) was used as the cationic polymer, and the polymeric surfactant poly(sodium N-undecanoyl-L-leucylvalinate) was used as the anionic polymer. Previous studies for both chiral and achiral separations have shown that PEM-coated capillaries have excellent reproducibilities, remarkable endurance, and strong stabilities against extreme pH values when used in open-tubular capillary electrochromatography (OT-CEC). In this study, the stability of the coatings was further investigated after exposure to 0.1 M and 1.0 M NaOH. Structural changes of these coatings were monitored using laser scanning confocal microscopy (LSCM) after flushing the capillaries with NaOH. This technique allowed observation of the degradation of the coatings. Observations are discussed in terms of separations using OT-CEC. Electropherograms obtained from the chiral separation of 1,1'-binaphthyl-2,2'-dihydrogenphosphate in OT-CEC showed a decrease in selectivity and an increase in electroosmotic mobility after long exposure to NaOH. The ability to recover the capillaries by exposure to NaOH was also demonstrated. Measurements of electroosmotic mobility and selectivity showed that 2-bilayer and 20-bilayer PEM coatings could be completely removed from the capillary surface after approximately 3.5 and 9.5 h, respectively, of continuous exposure to 1 M NaOH.

Chromatography, Micellar Electrokinetic Capillary↗

Capillary electrochromatography using polyelectrolyte multilayer coatings.

This review covers recent progress in polyelectrolyte multilayer (PEM) coatings applied to analytical separations using open-tubular capillary electrochromatography (OT-CEC). The simple preparation procedure involved in the PEM approach has provided some attractive features over other modes of capillary electrophoresis-based separations including packed column capillary electrochromatography (PC-CEC) and micellar electrokinetic chromatography (MEKC). PEM coatings have been used to alleviate the adsorption of basic analytes, to improve separations, and to improve the stability of the electroosmotic flow. Fundamental aspects of PEM coatings on surfaces and analytical separation platforms are briefly outlined in this review. In addition, applications of PEM coatings to fused-silica capillaries or microchip separation devices for the separation of small achiral or chiral analytes, as well as large biomolecules, are discussed.

Journal Article↗

Characterization and application of sodium di(2-ethylhexyl) sulfosuccinate and sodium di(2-ethylhexyl) phosphate surfactants as pseudostationary phases in micellar electrokinetic chromatography.

Sodium di(2-ethylhexyl) sulfosuccinate (DOSS) and sodium di(2-ethylhexyl) phosphate (NaDEHP) surfactants, with double alkyl chains and negatively charged headgroups, were characterized using fluorescence quenching, densitometry, and tensiometry techniques to determine their aggregation number, partial specific volume, and critical aggregation concentration. These two surfactants were then applied as pseudostationary phases in micellar electrokinetic chromatography (MEKC) for separations of alkyl phenyl ketones. The aggregation number of NaDEHP was found to be more than two-fold higher than that of DOSS. The partial specific volumes of NaDEHP and DOSS were found to be 0.9003 and 0.8371 mL/g, respectively. The critical aggregation concentrations are 5.12 and 1.80 mM for NaDEHP and DOSS, respectively. The DOSS surfactant provided a wider separation window and had a greater hydrophobic environment than the NaDEHP surfactant under the MEKC experimental conditions studied.

Chromatography, Micellar Electrokinetic Capillary↗

Chiral separations using a polypeptide and polymeric dipeptide surfactant polyelectrolyte multilayer coating in open-tubular capillary electrochromatography.

A polyelectrolyte multilayer (PEM) coating consisting of the polypeptide, poly(l-lysine) hydrobromide, poly(l-lysine) and the polymeric dipeptide surfactant, poly(sodium undecanoyl-l-leucyl-alaninate), poly(l-SULA), is investigated as a new medium for the separation of chiral analytes in open-tubular capillary electrochromatography (OT-CEC). In this approach, a stable PEM is constructed in situ by alternative rinses of the cationic polymer poly(l-lysine) and the anionic polymer poly(l-SULA). In previous studies, the PEM coating has been constructed by use of the cationic polyelectrolyte poly (diallydimethylammonium chloride), PDADMAC. In this study, we investigate the use of a biopolymer as the cationic polyelectrolyte. The results reported here indicate an increase in selectivity and resolution when poly(l-lysine) is used as the cationic polymer in place of PDADMAC. To evaluate the chromatographic performance of the PEM coating as a chiral stationary phase, the separation of the beta-blockers, labetalol and sotalol, and the binaphthyl derivatives, 1,1'-bi-2-naphthyl-2,2'-dihydrogen phosphate, 1,1'-bi-2-naphthol, and 1,1-binaphthyl-2,2'-diamine, are investigated. In addition, the effect of varying the amino acid order of the polymeric dipeptide surfactant on resolution is investigated. The number of bilayers also significantly influences the separation efficiency and resolution of enantiomers. The run-to-run and capillary-to-capillary reproducibilities are evaluated by calculating the relative standard deviations (RSDs) of the electroosmotic flow. These RSD values were found to be less than 1%. The coating is also stable and allows more than 290 runs to be performed in the same capillary. In addition, coupling of this chiral OT-CEC column with mass spectrometry is investigated.

Chromatography, Micellar Electrokinetic Capillary↗

Influence of the polydispersity of polymeric surfactants on the enantioselectivity of chiral compounds in micellar electrokinetic chromatography.

Poly(sodium undecenoyl-L-leucinate) (poly-L-SUL) was fractionated by the use of different molecular weight cutoff (MWCO) filters to narrow the polydispersity of the macromolecular sizes of the polymeric surfactant. The resulting polymeric surfactant fractions were characterized by the use of three techniques: (1) pulsed field gradient nuclear magnetic resonance (PFG-NMR) was used to determine the hydrodynamic radii, (2) analytical ultracentrifugation (AUC) was used to determine the molecular weights, and (3) steady-state fluorescence was used to determine the polarity of the nonfractionated and fractionated polymeric surfactants. From the data acquired from PFG-NMR, AUC, and fluorescence, it was noted that the hydrodynamic radii and molecular weight of the fractionated poly-L-SUL increased, while the polarity decreased with the increase in the size of the MWCO filter. However, a similarity in physical properties was observed between the nonfractionated and 10-30K fractionated poly-L-SUL except for the hydrodynamic radius and diffusion coefficients. The influence of different macromolecular sizes of poly-L-SUL on the chiral separation of phenylthiohydantion (PTH)-amino acids and coumarinic derivatives, as test analytes, was elucidated by the use of micellar electrokinetic chromatography (MEKC). The size of polymeric surfactants as a prerequisite for chiral separation was demonstrated by comparing the separation properties of fractionated versus nonfractionated polymeric surfactants. Fractionated poly-L-SUL resulted in enhanced resolution and separation efficiency of the test analytes as compared to the case of the nonfractionated poly-L-SUL. This observation indicates that minimizing polydispersity of polymeric surfactants may be important for some chiral separation applications.

Chromatography, Micellar Electrokinetic Capillary↗