PubMed Health⌕ Search

Biomedical subjects

J C Gardner

Publications and source records attributed to J C Gardner.

At least 37 records · Page 2Linked to original sources

A time-based stereoscopic depth mechanism in the visual cortex.

We propose a new depth mechanism, operating in the visual cortex, which uses temporal as well as spatial cues. By varying the timing of input to the two eyes, and the position of stimuli on the two receptive fields, we show that both temporal and spatial disparities influence the binocular responses of single cortical cells.

Animals↗

Effects of neonatally induced strabismus on binocular responses in cat area 18.

Responses to binocular visual stimulation were compared in cortical area 18 of normal cats and in cats in which one eye was exodeviated by surgery early in postnatal life. In contrast to normal cats where most units (58%) were binocularly activated, relatively few units (10%) in strabismic cats were activated well by stimulation of either eye. Rather individual units were driven mainly via one eye or the other but not both. In addition, there was a tendency for more units to be driven well via the unoperated eye than via the exodeviated eye. Fewer cells preferring vertically oriented than horizontally oriented stimuli were found in area 18 of strabismic cats. This trend was observed for cells driven by either the normal or deviated eye and was especially marked among the small number of binocularly activated cells. Generally binocular responses and binocular interactions were found with stimulation at corresponding retinal points. In a few striking instances, however, the receptive fields of binocular neurons were located on noncorresponding retinal points at loci which would enable the cat to correlate the two images of an external object despite the large divergent strabismus. Quantitative responses to binocular stimuli presented at varied disparities and to stimuli with varied directions of motion in depth were compared in normal and strabismic cats. Despite the large strabismus, a reduced fraction of cortical neurons displayed substantial binocular interactions. In fact, binocular facilitation was as marked in the population of cells studied in strabismic cats as it was in normal animals. The major effect of strabismus was a reduction in the strength of binocular inhibition when units were tested with sideways motion. Disparity-specific responses to motion toward or away from the organism were little affected by strabismus. The degree of binocular facilitation and binocular inhibition among the cell population was similar in normal and strabismic cats. A subpopulation of units encountered in strabismic cats showed strong disparity-specific interactions for motion toward or away from the animal without equivalent modulation for sideways moving stimuli. Units with these properties were not found in normal animals and may, therefore, represent a special adaptation of the strabismic animals.

Animals↗

The Lewin Report.

Explore the source record for details and available documents.

Legislation, Nursing↗

Image magnification in renal and superior mesenteric angiography: CT calculation and assessment of variables.

PURPOSE: To estimate the magnification that occurs in conventional renal and mesenteric angiography and to assess the influence of anatomic and technical variables. PATIENTS AND METHODS: Anticipated image magnification was derived solely from computed tomographic (CT) measurements obtained of 152 consecutive adult patients who underwent abdominal CT. Scans showed the distance from the origin and distal portions of both renal arteries to the anterior and posterior body surfaces, as well as the distance from the origin of the superior mesenteric artery to the lateral body surfaces. Assuming a 101.6-cm (40-inch) source-to-image receptor distance, the degree of magnification was calculated for posteroanterior, anteroposterior, and lateral radiographic imaging techniques. RESULTS: Calculated mean magnification for the proximal renal artery was 14.5% (range, 7.2%-25.8%) with posteroanterior imaging and 26.7% (range, 22.3%-36.7%) with anteroposterior imaging and a 10-cm-thick table. Mean magnification for the distal renal artery was 16.1% (range, 8.8%-25.3%) with posteroanterior imaging and 24.6% (range, 19.5%-36.4%) with anteroposterior imaging and a 10-cm-thick table. Magnification of the superior mesenteric artery was 17.8% (range, 12.5%-33.9%) with left lateral imaging. Regression analysis documented a linear relationship between percentage magnification and body diameter. CONCLUSION: Arterial location, imaging technique, and especially body habitus affect the degree of magnification in a predictable fashion.

Adolescent↗

Hand-assisted laparoscopy for the removal of an esophageal leiomyoma.

The patient is a 39-year-old male who presented with noncardiac chest pain. His evaluation disclosed an esophageal leiomyoma. In this paper we will demonstrate the pre-operative findings and technique for removal of a benign esophageal tumor using hand-assisted laparoscopy. The patient was discharged home 2 days postoperative and returned to work 2 weeks postoperative with complete resolution of his symptoms. Hand-assisted laparoscopy provides a postoperative course that parallels the recovery from conventional laparoscopy. Additionally, the tactile sense that a surgeon looses from conventional laparoscopy is regained by this technology.

Adult↗