Detection system for ocular refractive error measurement.

An automatic and objective system for measuring ocular refractive errors (myopia, hyperopia and astigmatism) was developed. The system consists of projecting a light target (a ring), using a diode laser (lambda = 850 nm), at the fundus of the patient's eye. The light beams scattered from the retina are submitted to an optical system and are analysed with regard to their vergence by a CCD detector (matrix). This system uses the same basic principle for the projection of beams into the tested eye as some commercial refractors, but it is innovative regarding the ring-shaped measuring target for the projection system and the detection system where a matrix detector provides a wider range of measurement and a less complex system for the optical alignment. Also a dedicated electronic circuit was not necessary for treating the electronic signals from the detector (as the usual refractors do); instead a commercial frame grabber was used and software based on the heuristic search technique was developed. All the guiding equations that describe the system as well as the image processing procedure are presented in detail. Measurements in model eyes and in human eyes are in good agreement with retinoscopic measurements and they are also as precise as these kinds of measurements require (0.125D and 5 degrees).

Astigmatism↗

The effects of forebrain multiple lesions on the pressor response induced by bilateral carotid occlusion in conscious rats.

In the present study, the effects of electrolytic lesions of the anteroventral third ventricle (AV3V) region and of the medial forebrain bundle (MFB) on the pressor response induced by bilateral carotid occlusion (BCO) in conscious intact and aortic baroreceptor-denervated (AD) rats were investigated. In intact control rats, BCO during 60 s produced a pressor response that could be divided into an early response (ER = 50 +/- 3 mmHg) that reachs a peak during the first 20 s and a sustained late response (LR), smaller than ER (32 +/- 2 mmHg), observed during the last 30 s. In intact-innervated rats, AV3V lesion (2 days) reduced ER (22 +/- 3 mmHg) and LR (16 +/- 2 mmHg), whereas the bilateral MFB lesions (6 days) mainly reduced LR (9 +/- 1 mmHg). Rats with simultaneous lesion of both the AV3V region and the MFB showed additional reduction of the ER (15 +/- 3 mmHg), but not LR (11 +/- 1 mmHg) when compared to the effect of MFB lesions alone. Compared to the AV3V lesion alone, LR but not ER was reduced in rats with a double lesion. In sham-lesioned rats, AD induced a significant increase in the pressor response to BCO (ER = 75 +/- 4 mmHg and LR = 65 +/- 3 mmHg) when compared to intact controls.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗