Detection system for ocular refractive error measurement.

Abstract

An automatic and objective system for measuring ocular refractive errors (myopia, hyperopia and astigmatism) was developed. The system consists of projecting a light target (a ring), using a diode laser (lambda = 850 nm), at the fundus of the patient's eye. The light beams scattered from the retina are submitted to an optical system and are analysed with regard to their vergence by a CCD detector (matrix). This system uses the same basic principle for the projection of beams into the tested eye as some commercial refractors, but it is innovative regarding the ring-shaped measuring target for the projection system and the detection system where a matrix detector provides a wider range of measurement and a less complex system for the optical alignment. Also a dedicated electronic circuit was not necessary for treating the electronic signals from the detector (as the usual refractors do); instead a commercial frame grabber was used and software based on the heuristic search technique was developed. All the guiding equations that describe the system as well as the image processing procedure are presented in detail. Measurements in model eyes and in human eyes are in good agreement with retinoscopic measurements and they are also as precise as these kinds of measurements require (0.125D and 5 degrees).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L Ventura, S J de Faria e Sousa, J C de Castro. 1998. Detection system for ocular refractive error measurement.. https://doi.org/10.1088/0031-9155%2F43%2F5%2F018

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Mathematical model of corneal surface smoothing after laser refractive surgery.

PURPOSE: To construct a quantitative model of corneal surface smoothing after laser ablation for refractive correction. DESIGN: Experimental study, interventional case series, and meta-analysis of literature. METHODS: A theory of epithelial smoothing in response to corneal contour change is derived from differential equations that describe epithelial migration, growth, and loss. Computer simulations calculate the effects on postoperative epithelial thickness, topography, refraction, and spherical aberration. Model parameter is matched with laser in situ keratomileusis (LASIK) outcome in literature and in a retrospective study of primary spherical myopic (77 eyes) and hyperopic (19 eyes) corrections. Surgically induced refractive change was the main outcome measure. RESULTS: Simulated epithelial remodeling after myopic ablation produces central epithelial thickening, reduction in achieved correction, and induction of oblate spherical aberration. Simulation of hyperopic ablation shows peripheral epithelial thickening, a larger reduction in correction, and induction of prolate spherical aberration. Simulation using a minus cylinder laser ablation pattern shows decreased astigmatism correction and increased hyperopic shift. In the LASIK series, linear regression of achieved correction vs ablation setting in hyperopic and minus cylinder corrections shows slopes of 0.97, 0.71, and 0.74, respectively. These clinical results match model predictions when the smoothing constant is set at 0.32, 0.63, and 0.55 mm, respectively. CONCLUSIONS: Epithelial thickness modulations after ablation can be modeled mathematically to explain clinically observed regression and induction of aberration. The cornea appears to smooth over ablated features smaller than approximately 0.5 mm. The model provides an approach for designing ablation patterns that precompensate for the smoothing to improve final outcome.

Astigmatism↗

Corneal ectasia detected 32 months after LASIK for correction of myopia and asymmetric astigmatism.

We report a case of corneal ectasia detected 32 months after laser in situ keratomileusis (LASIK) for correction of -4.25 diopters (D) of myopia associated with -2.00 D of regular but slight asymmetric astigmatism. The patient retained stable visual acuity for 15 months postoperatively. The preoperative corneal thickness was 540 microm, and the postablation untouched stroma was assumed to be 290 microm. Although a rare complication of LASIK, corneal ectasia can occur, and there is no consensus regarding how much stroma should be left intact to avoid it. Until we have a better understanding of corneal strength, we think surface photorefractive keratectomy or laser-assisted subepithelial keratectomy ablations should be considered instead of LASIK in borderline cases.

Astigmatism↗

Visual dysfunction in artists.

The representation of the world provided by an artist is often modified by abnormalities in the visual pathways. Some artists have used these distortions to create a particular style. Controversy surrounds earlier artists whose visual function was not well documented historically. Drugs and psychiatric disease may also modify the artist's imagery.

Astigmatism↗