PubMed Health⌕ Search

Biomedical subjects

J Cazaux

Publications and source records attributed to J Cazaux.

5 recordsLinked to original sources

Simultaneous and minimally invasive assessment of muscle tolerance and bioavailability of different volumes of an intramuscular formulation in the same animals.

Evaluation of skeletal muscle tolerance during development of new drug formulations for i.m. use is most often based on terminal methods performed in the target species after slaughtering. The objective of this study was to evaluate the effect of muscle damage on the pharmacokinetic parameters of the drug delivered into the muscle using an alternative, noninvasive method. Phenylbutazone (PBZ) was used as the test article. Six ewes received increasing volumes of a 20% PBZ i.m. formulation, according to a cross-over design, and an i.v. bolus of the same formulation. Serial blood samples were taken, and a pharmacokinetic analysis of the plasma activity of creatine kinase and plasma PBZ concentrations was carried out. The amount of muscle damage after i.m. administration of 2, 4, or 8 mL of PBZ, calculated from the area under the curve of plasma creatine kinase across time was 36, 76, and 178 g for a 70-kg ewe. The corresponding absolute bioavailability of PBZ was 100 +/- 32%, 96 +/- 19%, and 100 +/- 17%, and the maximal PBZ concentrations were 42 +/- 3.4, 74 +/- 8.8, and 119 +/- 18.2 microg/mL. The plasma clearance of PBZ (i.v.) was 4.2 +/- 0.94 mL.kg(-1).h(-1). In conclusion, the absolute bioavailability of PBZ after i.m. administration was not altered by the increased volume of formulation administered despite the overall increase in the extent of muscle damage.

Animals↗

Recent developments and new strategies in scanning electron microscopy.

In addition to improvements in lateral resolution in scanning electron microscopy, recent developments of interest here concern extension of the incident beam energy, E(0), over two decades, from approximately 20 keV to approximately 0.1-0.5 keV and the possibility of changing the take-off emission, alpha, of detected secondary electrons. These two degrees of freedom for image acquisition permit a series of images of the same field of view of a specimen to be obtained, each image of the series differing from the others in some aspect. The origins of these differences are explored in detail and they are tentatively interpreted in terms of the change in the secondary electron emission yield delta vs. E(0), delta = f(E(0)), and also of the change in delta vs. alpha, partial differentialdelta/ partial differentialalpha. Various origins for the chemical contrast and topographic contrast have been identified. Illustrated by correlating a secondary electron image and a backscattered electron image, use of the scatter diagram technique facilitates image comparison. The difference between the lateral resolution and the size of the minimum detectable detail is outlined to avoid possible errors in nanometrology. Some aspects related to charging are also considered and possible causes of contrast reversal are suggested. Finally, the suggested strategy consists of the acquisition of various images of a given specimen by changing one parameter: primary beam energy and take-off angle for conductive specimens; working distance or beam intensity for high-resolution experiments; scanning frequency for insulating specimens.

Microscopy, Electron, Scanning↗

About the role of the various types of secondary electrons (SE; SE; SE) on the performance of LVSEM.

The relative weight, delta(Beta), of the yield of secondary electrons, SE(2), induced by the backscattered electrons, BSE, with respect to that, delta(P), of secondary electrons, SE(1), induced by the primary electrons, PE, is deduced from simple theoretical considerations. At primary energies E(0) larger than E(M) (where the total SE yield delta = delta(P) + delta(B) is maximum), the dominant role of the backscattering events is established. It is illustrated in SEM by a direct comparison of the contrast between SE images and BSE images obtained at E(0) approximately 5 keV and E(0) approximately 15 keV on a stratified specimen. At energies E(0) less than E(M), the dominant role of SE(1) electrons with respect to SE(2) (and SE(3)) is established. It is illustrated by the better practical resolution of diamond images obtained with an in-lens detection in low voltage SEM E(0) approximately 0.2-1 keV range compared with that obtained with a lateral detector. The present contribution illustrates the improved performance of LVSEM in terms of contrast and of practical resolution as well as the importance of variable voltage methods for subsurface imaging. The common opinion that the practical lateral resolution is given by the incident spot diameter is also reconsidered in LVSEM.

Journal Article↗

Electronic core level microanalyses and microcopies in multipurpose apparatus.

Using an instrument equipped with two electron guns, an electron analyzer, and a Si(Li) diode detector, we developed microanalytical techniques based on inner-shell electron excitations by incident electrons and X-rays, that is, electron energy-loss spectroscopy (EELS) in the reflection mode; electron probe microanalysis (EPMA) and X-ray appearance potential spectroscopy (XAPS); electron-induced Auger electron spectroscopy (e-AES); X-ray photoelectron spectroscopy (XPS), X-ray absorption spectroscopy (XAS); X-ray induced AES (XAES), X-ray fluorescence analysis (XRF), and scanning X-ray radiography (SXR). The corresponding characteristic images (including X-ray microradiography and X-ray photoelectron microscopy) were obtained in the scanning mode. The principle of the apparatus is described. Each spectroscopy and microscopy is illustrated by an example. Their performance and limits are discussed.

Electron Probe Microanalysis↗

Application of the scatter diagram technique to the scanning electron microscope: preliminary results from diamond.

Using primary beam energies E0 ranging from 0.2 to 15 keV and an in-lens detector, a series of images of the same region of an artificial microstructured diamond sample have been acquired in scanning electron microscopy. Next, the images were analysed by using a scatter diagram technique to underline the topographic contrast change and contrast reversal. The results obtained from 0.5 to 15 keV are discussed with the help of an expression derived from the constant loss model for the secondary electron yield delta of diamond, but including the respective roles of the angle of incidence, i, and of the angle of detection, alpha. More surprising is the quality of images obtained at a beam energy as low as 0.2 keV, and more difficult to explain is the significant contrast change between 0.2 keV and 0.5 keV. For the first time, scatter diagrams are used as a diagnostic tool in scanning electron microscopy, and after some improvements it is hoped that the experimental approach followed here may lead to quantitative estimates of the local tilts of a specimen surface.

Journal Article↗