Recent developments and new strategies in scanning electron microscopy.

Abstract

In addition to improvements in lateral resolution in scanning electron microscopy, recent developments of interest here concern extension of the incident beam energy, E(0), over two decades, from approximately 20 keV to approximately 0.1-0.5 keV and the possibility of changing the take-off emission, alpha, of detected secondary electrons. These two degrees of freedom for image acquisition permit a series of images of the same field of view of a specimen to be obtained, each image of the series differing from the others in some aspect. The origins of these differences are explored in detail and they are tentatively interpreted in terms of the change in the secondary electron emission yield delta vs. E(0), delta = f(E(0)), and also of the change in delta vs. alpha, partial differentialdelta/ partial differentialalpha. Various origins for the chemical contrast and topographic contrast have been identified. Illustrated by correlating a secondary electron image and a backscattered electron image, use of the scatter diagram technique facilitates image comparison. The difference between the lateral resolution and the size of the minimum detectable detail is outlined to avoid possible errors in nanometrology. Some aspects related to charging are also considered and possible causes of contrast reversal are suggested. Finally, the suggested strategy consists of the acquisition of various images of a given specimen by changing one parameter: primary beam energy and take-off angle for conductive specimens; working distance or beam intensity for high-resolution experiments; scanning frequency for insulating specimens.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Cazaux. 2005. Recent developments and new strategies in scanning electron microscopy.. https://doi.org/10.1111/j.0022-2720.2005.01414.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Instabilities in nanoporous media.

Rayleigh instabilities in thin polymer films confined within nanoporous alumina membranes were studied. Thin films of poly(methyl methacrylate) (PMMA) were prepared by filling cylindrical nanopores in an anodic aluminum oxide (AAO) membrane with a PMMA solution in chloroform followed by solvent evaporation. When the PMMA nanotubes were annealed above the glass transition temperature (Tg), undulations in the film thickness were observed that were induced by a Rayleigh instability. The amplitude of the undulations increased with time and eventually bridged across the cylindrical nanopore in the AAO membrane, resulting in the formation of polymer nanorods with periodic encapsulated holes. A similar behavior was observed when PMMA films were confined within carbon nanotubes (CNTs). The Rayleigh instabilities in these confined geometries offer a novel means of controlling and fabricating the polymer nanostructures. These compartmentalized nanorods may have potential applications as delivery devices.

Microscopy, Electron, Scanning↗

Efficient and sensitive capacitive readout of nanomechanical resonator arrays.

Here we describe all-electronic broadband motion detection in radio frequency nanomechanical resonators. Our technique relies upon the measurement of small motional capacitance changes using an LC impedance transformation network. We first demonstrate the technique on a single doubly clamped beam resonator with a side gate over a wide range of temperatures from 20 mK to 300 K. We then apply the technique to accomplish multiplexed readout of an array of individually addressable resonators, all embedded in a single high-frequency circuit. This technique may find use in a variety of applications ranging from ultrasensitive mass and force sensing to quantum information processing.

Microscopy, Electron, Scanning↗