PubMed Health⌕ Search

Biomedical subjects

J Doffin

Publications and source records attributed to J Doffin.

5 recordsLinked to original sources

[Experimental simulation of blood flow perturbations induced by the placement of caval filters and thrombi].

Implantation of caval filters to prevent thrombo-embolism is a common medical option for twenty years, since the standard Greenfield model. The numerous new models with various geometries have been the subject of many studies aimed at testing their effectiveness in clot capture and the stability of their fixation to the vein, but very few ones are dedicated to the influence of their shape on blood flow, and to the flow disturbances induced by trapped clots shape and location. So, we have designed a caval blood flow simulation test bench of different filters and clot models. Opcetra and LGM filters were furnished with a reference regular input flow of physiological viscosity fluid. Rigid thrombus model, trapped in filter middle, was a one centimetre diameter sphere; and a recent soft one, which could model itself on the final part of the capture zone, was a two centimetres high cone. Perturbations, eddies, trajectories and velocities were recorded by particles visualization and ultrasound velocimetry. Downstream the Opcetra, velocity vectors were practically axial, no eddies could be seen; the central cylinder had changed the input parabolic flow into a one with two symmetrical maxima. For LGM, on the one hand, from the middle, the sheet branches perturbed the flow and induced several jets. On the other hand, the end ring had created an helicoïdal wake which extended up to three centimetres. With thrombi models, for Opcetra, a central spherical clot induced eddies inside the filter, but smoothed the two maxima of the profile, which vanished more rapidly. For the LGM, a central spherical clot increased the perturbations, whereas a final conical one decreased them. Finally, it was clear that filter shape, capture location and clot aspect were the leading causes of the hydrodynamic induced disturbances and might be important for the trapped clots evolution.

Biomechanical Phenomena↗

Blood viscosity measurements in both extensional and shear flow by a falling ball viscometer.

A falling ball viscometer is used to measure whole blood and plasma viscosities. The principle of the device is to determine the fall time of a ball contained in a disposable syringe; the periodic run of the sphere prevents blood sedimentation during the measuring cycle but does not prevent the aggregation process which takes place with a short relaxation time. The analysis of the flow field is discussed relative to previous papers. The study of the dynamics of the falling ball provides two characteristic rates of deformation for the mixed extensional and shear flow field. The Reynolds numbers are calculated using different velocities and radii. Results on blood and plasma viscosity of patients suffering from rheumatoid arthritis are given in relation with clinical and biological indexes.

Arthritis, Rheumatoid↗

[Hydredynamic bench for pulsatile flows. Application to hemodynamic studies (author's transl)].

Oscillatory or pulsatile flows are produced on a hydrodynamic bench by a volumetric gear pump. The moto-pump group is an original device which is very different from other systems. It is driven by a wave synthesizing generator which enables any flow rate to be produced especially oscillatory, pulsatile or physiological flow. The synthesizing generator delivers a periodic wave with variable amplitude, shape and frequency. The moto-pump group is controlled by an amplifying comparator; it produces a flow whose rate follows the control signal. A study of the modifications of flow patterns induced by models of vascular stenoses has been performed with this bench. The study of the velocity distribution has been effected with a pulsed Doppler ultrasonic velocimeter.

Biomedical Engineering↗

Doppler spectrum analysis and vascular imaging in the diagnosis of extracranial carotid artery disease.

Ultrasound methods are well suited for the exploration of the carotid system. High resolution echography can visualize atheromatous defects on the vessels walls with a resolution better than one mm, whereas Doppler examination detects haemodynamic disturbances due to these plaques. Conventional Doppler examination can reveal moderate or severe stenosis (greater than 60%); the recent development of frequency analysis of the Doppler audio signal makes now possible the detection of very light haemodynamic disturbances due to low grade stenosis even as small as 15%. Spectral distribution abnormalities have been classified in four grades according to their amplitude. The combination of the morphological and functional data provided by echography and Doppler spectrum analysis has drastically increased the diagnostic possibilities of the ultrasound methods in the field of the extracranial vascular pathology. With a new duplex system which combines echography and C.W. Doppler examination (duplex probe) it is possible to detect, and quantify carotid stenosis (in percentage of the lumen reduction), and to evaluate blood flow volume in ml/mn.

Carotid Artery Diseases↗