Significance of automated stenosis detection during quantitative angiography. Insights gained from intracoronary ultrasound imaging.

BACKGROUND: Automated stenosis analysis is a common feature of commercially available quantitative coronary angiography (QCA) systems, allowing automatic detection of the boundaries of the stenosis, interpolation of the expected dimensions of the coronary vessel at the point of obstruction, and angiographically derived estimation of atheromatous plaque size. However, the ultimate meaning of this type of analysis in terms of the degree of underlying atherosclerotic disease remains unclear. We investigated the relationship between stenosis analysis performed with QCA and the underlying degree of atherosclerotic disease judged by intracoronary ultrasound (ICUS) imaging. METHODS AND RESULTS: In 40 coronary stenoses, automated identification of the sites of maximal luminal obstruction and the start of the stenosis was performed with QCA by use of curvature analysis of the obtained diameter function. Plaque size at these locations also was estimated with ICUS, with an additional ICUS measurement immediately proximal to the start of the stenosis. Crescentlike distribution of plaque, indicating an atheroma-free arc of the arterial wall, was recorded. At the site of the obstruction, total vessel area measured with ICUS was 16.65 +/- 4.04 mm2, whereas an equivalent measurement obtained from QCA-interpolated reference dimensions was 7.48 +/- 3.30 mm2 (P = .0001). Plaque area derived from QCA data was significantly less than that calculated from ICUS (6.32 +/- 3.21 and 13.29 +/- 4.22 mm2, respectively; mean difference, 6.92 +/- 4.43 mm2; P = .0001). At the start of the stenosis identified by automated analysis, ICUS plaque area was 9.38 +/- 3.17 mm2, and total vessel area was 18.77 +/- 5.19 mm2 (50 +/- 11% total vessel area stenosis). The arterial wall presented a disease-free segment in 28 proximal locations (70%) but in only 5 sites (12%) corresponding to the start of the stenosis and none at the obstruction (P = .0001). At the site of obstruction, all vessels showed a complete absence of a disease-free segment, and the atheroma presented a cufflike or all-around distribution with a variable degree of eccentricity. CONCLUSIONS: At the site of maximal obstruction, QCA underestimated plaque size as measured with ICUS. Atherosclerotic disease was consistently present at the start of the stenosis and was used as a reference site by automated stenosis analysis. At the start of the stenosis, ICUS demonstrated a mean 50 +/- 11% total vessel area stenosis, with a characteristic loss of disease-free arcs of arterial wall present in proximal locations. Thus, the site identified by automated stenosis analysis as the start of the stenosis does not represent a disease-free site but rather the place where compensatory vessel enlargement fails to preserve luminal dimensions, a phenomenon that seems related to the observed loss of a remnant arc of normal arterial wall.

Aged

Impact of plaque morphology and composition on the mechanisms of lumen enlargement using intracoronary ultrasound and quantitative angiography after balloon angioplasty.

Limited information is provided by angiography on plaque morphology and composition before balloon angioplasty. Identification of plaques associated with reduced lumen gain or a high complication rate may provide the rationale for using alternative revascularization devices. We studied 60 patients with quantitative angiography and intracoronary ultrasound (ICUS) before and after balloon dilation. Angiography was used to measure transient wall stretch and elastic recoil. ICUS was used to investigate the mechanisms of lumen enlargement among different plaque compositions and in the presence of a disease-free wall (minimal thickness < or = 0.6 mm). Compared with ultrasound, angiography underestimated the presence of vessel calcification (13% vs 78%), lumen eccentricity (35% vs 62%), and wall dissection (32% vs 57%). ICUS measurements showed that balloon angioplasty increased lumen area from 1.82 +/- 0.51 to 4.81 +/- 1.43 mm2. Lumen enlargement was the result of the combined effect of an increase in the total cross-sectional area of the vessel (wall stretching, 43%) and of a reduction in the area occupied by the plaque (plaque compression or redistribution, 57%). Vessels with a disease-free wall had smaller lumen gain than other types of vessels (2.13 +/- 1.26 vs 3.59 +/- mm2, respectively, p < 0.01). Wall stretching was the most important mechanism of lumen enlargement in vessels with a disease-free wall (79% vs 37% in the other vessels). Angiography revealed a direct correlation between temporary stretch and elastic recoil that was responsible for 26% of the loss of the potential lumen gain. Thus, lumen enlargement after balloon angioplasty is the combined result of wall stretch and plaque compression or redistribution. ICUS indicates that vessels with a remnant arc of disease-free wall are dilated mainly by wall stretching compared with other types of vessels and are associated with a smaller lumen gain.

Aged

Ischemia-related lesion characteristics in patients with stable or unstable angina. A study with intracoronary angioscopy and ultrasound.

BACKGROUND: Postmortem-derived findings support the common beliefs that lipid-rich coronary plaques with a thin, fibrous cap are prone to rupture and that rupture and superimposed thrombosis are the primary mechanisms causing acute coronary syndromes. In vivo imaging with intracoronary techniques may disclose differences in the characterization of atherosclerotic plaques in patients with stable or unstable angina and thus may provide clues to which plaques may rupture and whether rupture and thrombosis are active. METHODS AND RESULTS: We assessed the characteristics of the ischemia-related lesions with coronary angiography and intracoronary angioscopy and determined their compositions with intracoronary ultrasound in 44 patients with unstable and 23 patients with stable angina. The angiographic images were classified as noncomplex (smooth borders) or complex (irregular borders, multiple lesions, thrombus). Angioscopic images were classified as either stable (smooth surface) or thrombotic (red thrombus). The ultrasound characteristics of the lesion were classified as poorly echo-reflective, highly echo-reflective with shadowing, or highly echo-reflective without shadowing. There was a poor correlation between clinical status and angiographic findings. An angiographic complex lesion (n = 33) was concordant with unstable angina in 55% (24 of 44); a noncomplex lesion (n = 34) was concordant with stable angina in 61% (14 of 23). There was a good correlation between clinical status and angioscopic findings. An angioscopic thrombotic lesion (n = 34) was concordant with unstable angina in 68% (30 of 44); a stable lesion (n = 33) was concordant with stable angina in 83% (19 of 23). The ultrasound-obtained composition of the plaque was similar in patients with unstable and stable angina. CONCLUSIONS: Angiography discriminates poorly between lesions in stable and unstable angina. Angioscopy demonstrated that plaque rupture and thrombosis were present in 17% of stable angina and 68% of unstable angina patients. Currently available ultrasound technology does not discriminate stable from unstable plaques.

Adult

Can intracoronary ultrasound correctly assess the luminal dimensions of coronary artery lesions? A comparison with quantitative angiography.

In 62 patients with angina pectoris Canadian Class III and IV, the luminal dimensions of 25 pre-PTCA and 56 post-PTCA lesions without occlusion were examined with a 4.3 F 30 MHz mechanical ultrasound imaging catheter, and analysed off-line using ultrasound cross-sectional area (U-CSA) measurements from s-VHS video images (n = 81). In addition, 42 angiographically normal coronary segments were examined. At the site of the examination, the U-CSA was integrated centrally to the leading edge echo of the inner contour of the vessel wall and the corresponding angiographic cinefilm images were analysed by edge detection using the Cardiovascular Angiography Analysis System. The obstruction diameter (at the lesion) and the mean vessel diameter (at normal sites) were used to calculate the angiographic cross-sectional area (A-CSA) assuming a circular model. U-CSA values were compared with the corresponding A-CSA values using t-test and linear regression analysis. The study showed that larger CSA are measured with ultrasound than with angiography. (P < 0.0001). An acceptable correlation was found between U-CSA and A-CSA values in normal coronary segments (correlation coefficient: r = 0.73, mean diff. = 1.44 +/- 1.22 mm2). However, the correlation was poor at the site of pre-PTCA lesions (r = 0.62, mean diff. = 1.81 +/- 1.14 mm2) and deteriorated following PTCA (r = 0.47, mean diff. = 1.28 +/- 2.20 mm2). No correlation was found between the degree of lumen eccentricity measured with intracoronary ultrasound (ICUS) and the individual differences between U-CSA and A-CSA values.(ABSTRACT TRUNCATED AT 250 WORDS)

Angioplasty, Balloon, Coronary

Mechanisms of luminal enlargement and quantification of vessel wall trauma following balloon coronary angioplasty and directional atherectomy.

OBJECTIVES: The purpose of this study was to assess the dual action of lumen enlargement and vessel wall damage following either balloon angioplasty or directional atherectomy, using intracoronary ultrasound, and angioscopy. BACKGROUND: Differences in the mechanisms of action of balloon angioplasty and directional atherectomy may have a significant bearing on the immediate outcome and the restenosis rate at 6 months. METHODS: A total of 36 patients were studied before and after either balloon angioplasty (n = 18) or directional atherectomy (n = 18). Ultrasound measurements included changes in lumen area, external elastic membrane area and plaque burden. In addition, the presence and extent of dissections were assessed to derive a damage score. Angioscopic assessment of the dilated or atherectomized stenotic lesions was translated into semi-quantitative dissection, thrombus and haemorrhage scores. RESULTS: Atherectomy patients had a larger angiographic vessel size compared with the angioplasty group (3.55 +/- 0.46 mm vs 3.00 +/- 0.64 mm, P < 0.05); however, minimal lumen diameter (1.18 +/- 0.96 mm vs 0.85 +/- 0.49 mm) and plaque burden (17.04 +/- 3.69 vs 15.23 +/- 4.92 mm2) measurements did not differ significantly. As a result of plaque reduction, atherectomy produced a larger increase in luminal area than the angioplasty group (5.80 +/- 1.78 mm2 vs 2.44 +/- 1.36 mm2, P < 0.0001). Lumen increase after angioplasty was the result of 'plaque compression' (50%) and wall stretching (50%). Additionally, in both groups there was indirect angioscopic evidence of thrombus 'microembolization' as an adjunctive mechanism of lumen enlargement. Angioscopy identified big flaps in six and small intimal flaps in 11 of the atherectomized patients as compared with five and 12 patients in the angioplasty group. Changes in thrombus score following both coronary interventions were identical (0.72 +/- 3.42 points atherectomy vs -0.38 +/- 3.27 points balloon angioplasty, ns). CONCLUSIONS: Lumen enlargement after directional atherectomy is mainly achieved by plaque removal (87%), whereas balloon dilation is the result of vessel wall stretching (50%) and plaque reduction (50%). Despite the fact that the luminal gain achieved by directional atherectomy is twice that achieved with balloon angioplasty, the extent of trauma induced by both techniques seems to be similar.

Aged

Angioscopic versus angiographic detection of intimal dissection and intracoronary thrombus.

OBJECTIVES: This study was undertaken to compare coronary angioscopy with angiography for the detection of intimal dissection and intracoronary thrombus. BACKGROUND: It has been demonstrated previously that coronary angioscopy provides more intravascular detail than cineangiography. Both imaging methods have to be compared directly to assess the additional diagnostic value of angioscopy. METHODS: The angiograms and videotapes of 52 patients who had undergone angioscopy were reviewed independently by two observers unaware of other findings. Classic angiographic definitions were used for dissection and thrombus. Angioscopic dissection was defined as visible cracks or fissures on the lumen surface or mobile protruding structures that are contiguous with the vessel wall. Angioscopic thrombus was defined as a red, white or mixed red and white intraluminal mass. RESULTS: Angiography and angioscopy were in agreement in 40.4% of cases in the absence of thrombus and in 11.5% in the presence of thrombus. No fewer than 25 (48.1%) angioscopically observed thrombi remained undetected at angiography. With angioscopy as the standard, although the specificity of angiography for thrombus was 100%, sensitivity was very low at 19%. Angioscopic dissection was present in 40 patients (76.9%) versus angiographic dissection in 15 patients (28.8%). With regard to dissection, there was no correlation between the two imaging methods (r phi = 0.15, p = 0.29). CONCLUSIONS: Coronary angiography underestimates the presence of intracoronary thrombus. Angioscopy and angiography are complementary techniques for detecting and grading intimal dissections.

Adult

Quantitative coronary angiography in the estimation of the functional significance of coronary stenosis: correlations with dobutamine-atropine stress test.

OBJECTIVES: The purpose of this study was to determine the predictive value of quantitative coronary angiography in the assessment of the functional significance of coronary stenosis as judged from the development of left ventricular wall motion abnormalities during dobutamine-atropine stress echocardiography. BACKGROUND: Coronary angiography is the reference method for assessment of the accuracy of noninvasive diagnostic imaging techniques to detect the presence of significant coronary stenosis. However, use of arbitrary cutoff criteria for the interpretation of angiographic data may considerably influence the true diagnostic accuracy of the technique investigated. METHODS: Thirty-four patients without previous myocardial infarction and with single-vessel coronary stenosis were studied with both quantitative angiography and dobutamine-atropine stress echocardiography. Two different techniques of quantitative angiographic analysis--edge detection and videodensitometry--were used for measurement of minimal lumen diameter, percent diameter stenosis and percent area stenosis. Two-dimensional echocardiographic images were collected during incremental doses of intravenous dobutamine and later analyzed using a 16-segment left ventricular model. Angiographic cutoff criteria were derived from receiver-operating curves to define the functional significance of coronary stenosis on the basis of dobutamine-atropine stress echocardiography. RESULTS: The angiographic cutoff values with the best predictive value for the development of left ventricular wall motion abnormalities during dobutamine-atropine stress echocardiography were minimal lumen diameter of 1.07 mm, percent diameter stenosis of 52% and percent area stenosis of 75%. Minimal lumen diameter was found to have the best predictive value for a positive dobutamine stress test (odds ratio 51, sensitivity 94%, specificity 75%). CONCLUSIONS: Automated quantitative angiographic measurement of minimal lumen diameter is a practical and useful index for determining both the anatomic and functional significance of coronary stenosis, and a value of 1.07 mm is the best predictor for a positive dobutamine stress test.

Adult

Proliferation and extracellular matrix synthesis of smooth muscle cells cultured from human coronary atherosclerotic and restenotic lesions.

OBJECTIVES: The purpose of this study was to examine the proliferative capacity and extracellular matrix synthesis of human coronary plaque cells in vitro. BACKGROUND: Common to both primary atherosclerosis and restenosis are vascular smooth muscle cell proliferation and production of extracellular matrix proteins. The applicability to humans of experimental animal models of these processes has been questioned. METHODS: Primary atherosclerotic and restenotic lesions were excised by percutaneous directional coronary atherectomy in 93 patients. Smooth muscle cells were cultivated by an explant technique and identified by their morphology in culture, ultrastructural features under electron microscopy and immunostaining using monoclonal antibodies to smooth muscle cell alpha-actin. Proliferation in secondary culture was assessed with growth curves and the synthesis of collagen and sulfated glycosaminoglycans by the incorporation of 3H-proline and 35S-sulfate, respectively. These studies were also performed in cells derived from human umbilical artery media. RESULTS: Success rates for primary (45%) and secondary (12%) culture of coronary cells were not influenced by clinical variables or lesion category. Primary culture success was improved by the presence of organized thrombus in the plaque and in relation to increased maximal cell density of the atherectomy specimen. Restenotic cells displayed more rapid growth than did cells of primary atherosclerotic origin, which grew in a manner similar to that of umbilical artery cells. Mean calculated population-doubling times for the three cell groups were 52 h (95% confidence interval [CI] 48 to 58 h), 71 h (95% CI 62 to 83 h) and 74 h (95% CI 65 to 84 h), respectively. Restenotic and primary atherosclerotic cells did not differ in the synthesis of collagen ([mean +/- SEM] 0.034 +/- 0.004 vs. 0.033 +/- 0.004 nmol isotope.microgram protein-1, p = NS) or sulfated glycosaminoglycans (11.47 +/- 1.07 vs. 15.37 +/- 3.10 nmol isotope.microgram protein-1, p = NS), but the coronary cells synthesized significantly more collagen and sulfated glycosaminoglycans than did umbilical artery cells (0.019 +/- 0.004 and 5.43 +/- 1.00 nmol isotope.microgram protein-1, respectively, both p < 0.05). CONCLUSIONS: These data indicate that increased smooth muscle cell proliferation contributes to coronary restenosis in humans and support the concept that the extracellular matrix synthesis of adult smooth muscle cells is important to lesion formation.

Cell Division

Intracoronary ultrasound and angioscopic imaging facilitating the understanding and treatment of post-infarction angina.

We report on the use of intravascular ultrasound, coronary angioscopy and on-line quantitative angiography in an unstable patient soon after myocardial infarction. Combined intracoronary imaging made it possible to solve the therapeutic problem posed by an unusual angiographic appearance secondary to intracoronary thrombolysis during coronary recanalization. The pathological validation of the observations performed with angioscopy and intravascular ultrasound was made possible with the concomitant use of directional atherectomy.

Angina Pectoris

Late effects of locally delivered mitomycin C on formation of neointima and on vasomotor response to acetylcholine.

BACKGROUND: Balloon angioplasty damages endothelial cells and stimulates smooth muscle cell proliferation. The effects of local cytotoxic drug therapy on formation of neointima and late endothelial function are not known. This study was designed to determine whether direct infusion of mitomycin C via a microporous balloon catheter could significantly reduce formation of neointima after angioplasty. Furthermore, we investigated whether endothelial cell function is normal 7 weeks after the initial microporous angioplasty procedure. METHODS: In 34 New Zealand white rabbits, bilateral external iliac arteries underwent balloon angioplasty, followed by either high-dose (0.66 mg/kg) or low-dose (0.025 mg/kg) mitomycin C in one iliac artery and saline infusion in the contralateral artery, and a control group was given saline in both vessels. Formation of neointima was measured in the iliac arteries after 7 weeks by morphometry. Before sacrifice of 17 'angioplasty' rabbits and three undamaged rabbits, graded doses of acetylcholine and isosorbide dinitrate were infused in the distal aorta, and the iliac artery diameter was measured by computerized quantitative angiography. RESULTS: No significant differences in the absolute area of the intima or the intima: media ratio were demonstrated between control arteries and arteries that were directly infused with either high-dose or low-dose mitomycin. However, within the high-dose group, the mitomycin-treated vessel had a significantly lesser extent of formation of intimal hyperplasia (0.17 +/- 0.03 versus 0.27 +/- 0.03 mm2, P < 0.03) and lower intima: media area ratio (0.60 +/- 0.31 versus 1.09 +/- 0.42, P < 0.03) than the contralateral saline-treated vessel. Significant increases in mean luminal iliac artery diameter [0.18 mm (10.5%) at 1 min and 0.23 mm (13%) at 3 min, P < 0.05)] from baseline values following acetylcholine were observed in previously damaged iliac arteries. This vasodilatory response was not different from that in undamaged arteries. CONCLUSIONS: Local delivery of mitomycin C had no favorable effect on the inhibition of intimal hyperplasia compared with control saline-treated arteries. Normal endothelial function, determined on the basis of dilatory response to acetylcholine, can be demonstrated 7 weeks after balloon angioplasty injury.

Acetylcholine

Experimental validation of geometric and densitometric coronary measurements on the new generation Cardiovascular Angiography Analysis System (CAAS II).

Computer-assisted contour detection and videodensitometric cross sectional area assessment of coronary artery obstructions on the CAAS II system were validated in vitro and in vivo by angiographic cinefilm recording and automated measurement of stenosis phantoms (luminal diameter 0.5, 0.7, 1.0, 1.4, 1.9 mm) which were first inserted in a plexiglass model and then serially implanted in swine coronary arteries. "Obstruction diameter" (OD) and "obstruction area" (OA) values obtained from 10 in vitro and 19 in vivo images at the site of the artificial stenoses were compared with the true phantom dimensions. The in vitro assessment of OD yielded an accuracy of 0.00 +/- 0.11 mm (correlation coefficient: r = 0.98, y = 0.18 + 0.82x, standard error of estimate: SEE = 0.08), whereas the in vivo measurement of OD gave an accuracy of -0.01 +/- 0.18 mm (r = 0.94, y = 0.22 + 0.82x, SEE = 0.15). The assessment of OA gave an accuracy of -0.08 +/- 0.21 mm2 in vitro (r = 0.97, y = 0.08 + 0.99x, SEE = 0.22) and -0.22 +/- 0.32 mm2 in vivo (r = 0.95, y = 0.21 + 1.01x, SEE = 0.33). The mean reproducibility was +/- 0.09 mm for geometric measurements and +/- 0.21 mm2 for videodensitometric assessments, respectively. Thus, due to inherent limitations of the imaging chain, the reliability of geometric coronary measurements is still far superior to videodensitometric assessments of vessel cross sectional areas.

Absorptiometry, Photon

Quantitative angiography during coronary angioplasty with a single angiographic view: a comparison of automated edge detection and videodensitometric techniques.

Little information is available on the reliability of coronary luminal measurements obtained from quantitative analysis of a single angiographic view, an approach that is central to the practical use of on-line quantitative angiography. In the present study we investigated the contribution of two different techniques of quantitative angiography, edge detection (ED) and videodensitometry (VD), to the application of this concept during coronary angioplasty. Forty-six balloon angioplasty procedures were included in this study, all of them performed in a stenosis located in the mid right coronary segment. This coronary location was chosen to optimize data collection on luminal morphology and to minimize the number of factors that may adversely affect quantitative analysis with both techniques. In all cases two orthogonal angiographic projections were obtained before, after balloon dilatation, and at follow-up. Correlation coefficients and differences between orthogonal measurements obtained with each technique were used to evaluate the agreement between orthogonal readings at every stage of the procedure. The obtained correlation coefficients and mean differences (MD) between orthogonal measurements were as follows: before percutaneous transluminal coronary angiography (PTCA), 0.67 (MD 0.01 +/- 0.47 mm2) and 0.57 (MD 0.05 +/- 0.64 mm2) for ED and VD, respectively (Pitman's test for SD, p < 0.05); after balloon dilatation, 0.32 (MD -0.56 +/- 1.53 mm2) and 0.53 (MD -0.15 +/- 1.43 mm2) for ED and VD, respectively (paired t test for MD, p < 0.05); and at follow-up 0.79 (MD -0.15 +/- 0.97 mm2) and 0.73 (MD 0.17 +/- 1.16 mm2) for ED and VD, respectively (p = NS).(ABSTRACT TRUNCATED AT 250 WORDS)

Absorptiometry, Photon

Clinical and histological determinants of smooth-muscle cell outgrowth in cultured atherectomy specimens: importance of thrombus organization.

BACKGROUND: Coronary atherectomy provides a unique opportunity to obtain plaque tissue from a wide variety of clinical syndromes. We investigated the relation between the clinical status and histopathological substrate of tissue retrieved during directional coronary atherectomy and the proliferative and migratory potential of smooth-muscle cells judged from successful outgrowth during cell culture. METHODS: After directional coronary atherectomy, tissue samples were examined macroscopically, divided into two equal pieces, and separately subjected to cell culture and histopathological study. Cell culture was performed using an explant technique. In-vitro smooth-muscle cell outgrowth was related to clinical and histological variables. RESULTS: Atherosclerotic tissue was obtained from 98 consecutive atherectomy procedures. Histological examination revealed a broad spectrum of appearances, ranging from complex atheroma containing dense fibrous tissue, calcium deposits, macrophages, and necrotic debris to neointimal proliferation and organized thrombi. Smooth-muscle cell outgrowth was observed in 43 of the 98 samples (44%). Although not affected by any of the clinical variables, cell outgrowth was influenced by histological variables, in particular the presence of organizing thrombi. Outgrowth was successful in eight out of 10 samples with thrombus (80%) and in only 35 out of 88 (40%) without (P = 0.03). CONCLUSION: The presence of organizing thrombi in the retrieved tissue facilitates smooth-muscle cell outgrowth and suggests an enhanced proliferative and migratory potential. These findings may be relevant to the understanding of neointimal proliferation in coronary syndromes where mural thrombosis is likely to occur.

Angina Pectoris