PubMed HealthSearch

Biomedical subjects

J Escaned

Publications and source records attributed to J Escaned.

23 records · Page 2Linked to original sources

Pleural effusion following coronary perforation during balloon angioplasty: an unusual presentation of the postpericardiotomy syndrome.

We report on the development of features of the postpericardiotomy syndrome following coronary perforation during balloon angioplasty, in a patient that was managed conservatively. The case illustrates that while cardiac tamponade does not invariably follow coronary perforation, late consequences derived from this complication may occur. It also widens the spectrum of conditions where the postpericardiotomy syndrome has been observed.

Angina Pectoris

Evaluation of a theoretical Doppler index to noninvasively estimate peak dP/dt using continuous wave Doppler ultrasound of ascending aortic flow in man.

A theoretical formula for calculation of peak dP/dt was derived using parameters obtained from continuous wave Doppler echocardiography signals of aortic blood flow. The direct proportional relationship between the main variables of this formula and invasively measured peak dP/dt was validated in 20 patients undergoing routine diagnostic cardiac catheterization. Doppler signals of aortic flow were obtained simultaneously to invasive pressure recordings with a 2 MHz continuous wave transducer via the suprasternal echocardiographic window. The Doppler signals were recorded on magnetic tape and measurements were made with digital calipers by two independent, blinded observers. The following parameters were measured: peak velocity (V) and time from onset of ejection to peak velocity (T). V2/T, the variable of the derived formula, was calculated for each of the observer's measured parameters and showed a very high interobserver correlation. The two observers' measurements of each parameter were averaged for each patient and the resulting mean was used in calculating the V2/T and mean acceleration. 4. A good correlation of V2/T with invasively measured peak dP/dt was obtained. Our derived index of left ventricular function showed a higher correlation with peak dP/dt compared to other Doppler indices of ventricular function. V2/T may provide a noninvasive method for estimating peak dP/dt.

Aorta

Changes in Doppler indices of cardiac function during and after percutaneous transluminal coronary angioplasty.

OBJECTIVE: To assess the sensitivities of Doppler indices to changes in global cardiac function during and after controlled myocardial ischaemia induced by coronary angioplasty. DESIGN: Continuous wave Doppler signals of aortic flow were recorded during coronary angioplasty. The following Doppler indices of cardiac function were measured before, during, and after balloon inflation: V (peak velocity), MA (mean acceleration), V2/T (T = time from onset to peak ejection), and MD (minute distance corrected for baseline heart rate). SETTING: A tertiary care cardiological unit in a university hospital. PATIENTS: Sixteen patients undergoing coronary angioplasty of the left anterior descending coronary artery. Eight patients had multivessel disease. MAIN OUTCOME MEASURES: The primary outcome measures were planned before data collection began. RESULTS: 12 patients showed a significant fall of three or more Doppler indices from their baseline values during balloon inflation. This occurred in all patients with multivessel disease. The Doppler indices V2 T, MD, V, and MA fell by 43.7%, 37.7%, 27.4%, and 23% respectively from their baseline values (p less than 0.0001). The relative sensitivities of the Doppler indices to ischaemia were V2/T greater than MD (p less than 0.02), MD greater than (p less than 0.001), and V greater than MA (p less than 0.01). The impairment of global left ventricular function resulting from brief balloon inflation during single vessel angioplasty was reversible in all the patients. CONCLUSIONS: The Doppler indices V2/T, MD, V, and MA are all sensitive, in order of magnitude, to falls in global cardiac function resulting from ischaemia. They may prove useful for assessing cardiac function during ischaemia in the clinical setting.

Adult