Workplace characterisation in case of rail transport of radioactive materials.

IRSN has been asked by SNCF (French Railways) to carry out measurements in order to establish the values of ambient dose equivalents H*(10) in the vicinity of shipments of radioactive materials to assess the external exposure to ionising radiation to which employees may be subjected during the carriage of radioactive goods. Detailed dosimetric characterisations of the wagons have been made and the external exposure at different stages of the work that is done by the employees have been measured in terms of H*(10). For the study presented in this paper, and corresponding to a used fuel shipment composed of UO2 and UO2-PuO2, it has been observed that the photon and neutron doses are very similar. In addition, the order of magnitude of the total dose integrated by an employee who would carry out 100 times the series of essential operational tasks, has been found to be approximately 250 microSv. This value is compared with those observed for other previously investigated shipments involving the exposure to photon fields only.

Body Burden↗

Assessing exposure to cosmic radiation on board aircraft.

The assessment of exposure to cosmic radiation on board aircraft is one of the preoccupations of organizations responsible for radiation protection. The cosmic radiation particle flux increases with altitude and latitude and depends on the solar activity. The radiation exposure has been estimated on several airlines using transatlantic, Siberian and transequatorial routes on board subsonic and supersonic aircraft, to illustrate the effect of these parameters. Measurements have been obtained with a tissue equivalent proportional counter using the microdosimetric technique. Data have been collected at maximum solar activity in 1991-92 and at minimum in 1996-98. The lowest mean dose rate measured was 3 microSv/h during a Paris-Buenos Aires flight in 1991; the highest was 6.6 microSv/h during a Paris-Tokyo flight using a Siberian route and 9.7 microSv/h on Concorde in 1996-97. The mean quality factor is around 1.8. The corresponding annual effective dose, based on 700 hours of flight for subsonic aircraft and 300 hours for Concorde, can be estimated between 2 mSv for least-exposed routes and 5 mSv for more exposed routes.

Aircraft↗

TEPC measurements obtained on the Mir space station.

Measurements of the radiation environment inside the Mir space station were performed with a tissue equivalent proportional counter (TEPC) during the Antares mission in 1992, and over a long period following it. Interesting results concerning radiation measurements show (a) the South Atlantic Anomaly crossing, (b) the increase of radiation near the poles, and (c) the effects of solar particle events (the most important one occurring in early November 1992). This data also provides information about the dose and the quality factor of the radiation to which the cosmonauts were exposed during different missions. These data are compared with measurements obtained using a solid state detector.

Arctic Regions↗

New approach for dose reconstruction: application to one case of localized irradiation with radiological burns.

When localized accidental irradiation occurs, it is necessary to determine the extent to which tissues and vital organs have been damaged, mainly in the vicinity of the source. At present, biological markers cannot be used to estimate the heterogeneity of the dose distribution. An alternative is to map the absorbed dose in the different regions of the body. Using a Monte Carlo calculation code, it is possible to simulate the accident while taking into account the specific morphology of the irradiated individual and his environment, as well as the source characteristics. The calculated values are matched to the clinical signs of the lesion, particularly around the rim of the radiation-induced necrosis. This technique was applied successfully on two patients who presented very severe lesions due to acute localized irradiation after an accident that occurred at Lilo (Georgia) in 1996-1997; only the most demonstrative case is presented here.

Bone and Bones↗

Assessing exposure to cosmic radiation during long-haul flights.

The assessment of exposure to cosmic radiation on board aircraft is one of the concerns of organizations responsible for radiation protection. Cosmic-particle flux increases with altitude and latitude and depends on solar activity. To illustrate the effect of these parameters, exposure has been estimated on several airlines operating subsonic and supersonic aircraft on transatlantic, Siberian and transequatorial routes. Measurements have been made with a tissue-equivalent proportional counter using the microdosimetric technique. This type of system provides the absorbed dose, the ambient dose equivalent, the mean quality factor, and the dose distribution as a function of lineal energy. Data were collected at maximum solar activity in 1991-1992 and at minimum activity in 1996-1998. The lowest mean dose rate measured was 3 microSv h(-1) during a Paris-Buenos Aires flight in 1991. The highest rates were 6.6 microSv h(-1) during a Paris-Tokyo flight on a Siberian route and 9.7 microSv h(-1) on Concorde in 1996-1997. The mean quality factor is around 1.8. The corresponding annual effective dose, based on 700 h of flight for subsonic aircraft and 300 h for Concorde, can be estimated at between 2 mSv for the least-exposed routes and 5 mSv for the more-exposed routes.

Aviation↗

The use of TEPC for reference dosimetry.

The radiation fields on board aircraft are quite complex and cover an energy range that is unusual in ordinary radiation protection work. Usually dosemeters measure only one radiation quality and the mixture found on board makes measurements complicated. There is also some doubt when it comes to the best choice of quantity for this application and no radiation standards exist for this kind of radiation field. For those reasons there is a need to find a standard measurement procedure that could serve as a reference for other, maybe simpler, measurements or for calculations of route doses. The only direct reading dosemeter that both measures the absorbed dose to tissue and the radiation quality (in terms of lineal energy) is the tissue-equivalent proportional counter (TEPC). The instrument was originally developed for scientific purposes and is still used as such. The detector consists of a gas filled cavity surrounded by a few mm thick wall. Both wall and gas consists of tissue-like material. The measurement principles are explained. Results observed with TEPC instruments are demonstrated. A preliminary collection of data reported by different groups from measurements on board aircraft will be shown. The results agree within +/- 20%. The conclusion is that TEPC instruments have the capacity of serving as reference instruments.

Aerospace Medicine↗

Dosimetry during the first IBIS facility flight.

The dosimetry of cosmic rays was performed during the first experimental flight of the IBIS facility. Different thermoluminescent detectors (TLD) have been used to measure the contribution of the low linear energy transfer component (LET < 10 keV/micrometer) and plastic nuclear track detectors (PNTD) for the high linear energy tranfer (LET) component. Several parameters of tracks have been measured to determine the LET spectra of primary and secondary charged particles. The total absorbed dose rate (TLD+PNTD) during the flight was 0.23 mGy/day and the dose equivalent rate using the ICRP 60 was 0.52 mSv/day. The corresponding mean quality factor was 2.4. These results are in agreement with those obtained aboard the MIR station with a tissue equivalent proportional counter.

Cosmic Radiation↗

Dosimetry for occupational exposure to cosmic radiation.

In the course of their work, aircraft crew and frequent flyers are exposed to elevated levels of cosmic radiation of galactic and solar origin and secondary radiation produced in the atmosphere, aircraft structure, etc. This has been recognised for some time and estimates of the exposure of aircraft crew have been made previously and included in, for example, UNSCEAR (United Nations Scientific Committee on the Effects of Atomic Radiation) publications. The recent increased interest has been brought about by several factors--the consideration that the relative biological effectiveness of the neutron component as being underestimated; the trend towards higher cruising altitudes for subsonic commercial aircraft and business jet aircraft; and, most importantly, the recommendations of the International Commission on Radiological Protection (ICRP) in Publication 60, and the revision of the Euratom Basic Safety Standards Directive (BSS). In 1992, the European Dosimetry Group (EURADOS) established a Working Group to consider the exposure to cosmic radiation of aircraft crew, and the scientific and technical problems associated with radiation protection dosimetry for this occupational group. The Working Group was composed of fifteen scientists (plus a corresponding member) involved in this field of study and with knowledge of radiation measurement at aviation altitudes. This paper is based on the findings of this Working Group. Where arrangements are made to take account of the exposure of aircraft crew to cosmic radiation, dose estimation procedures will not be necessary for persons for whom total annual doses are not liable to exceed 1 mSv, and therefore, in general, for crew on aircraft not routinely flying above 8 km. Where estimates of effective dose and, in the case of female staff who are pregnant, equivalent dose to the embryo or fetus, are required (for regulatory or other purposes), it was concluded that the preferred procedure was to determine route doses and fold these with data on staff rostering.

Aircraft↗

Real time dose rate and LET spectrum aboard MIR station during 1992.

Since the end of July 1992, the NAUSICAA system, a low gas pressured tissue equivalent proportional counter, recorded in real time the dose equivalent rate, the absorbed dose rate, the quality factor and the Linear Energy Transfer spectra, aboard the Russian orbital station MIR. The results since the ANTARES mission are presented. Some parameters like the proton flux, the previous solar cycles, the location of the NAUSICAA system inside the station and the South Atlantic Anomaly crossing seem to have an influence on these results. The total dose equivalent (H) during the ANTARES mission (between 1992 July the 30th and August the 10th) was 12 mSv and the total absorbed dose (D) 6.4 mGy with a quality factor (Q) equal to 1.9. The NAUSICAA system gives a good knowledge of LET spectra for the first time in space dosimetry.

Atlantic Ocean↗

New results for the space radiation environment of MIR space station obtained by Liulin dosimeter-radiometer. Comparison with LET spectrometer NAUSICAA.

Since 1988 high sensitivity semiconductor dosimeter-radiometer "Liulin" worked on board of MIR space station. Device measured the absorbed dose rate and the flux of penetrating particles. The analysis of the data shows the following new results: In October 1989 and after March 24, 1991, two additional stable maximums in flux channel were observed in the southern-eastern part of South Atlantic Anomaly (SAA). These two maximums existed at least several months and seem to be due to trapped high energy electron and proton fluxes. In April 1991 additional maximums were localized in the following geographical coordinates regions: latitude = (-35 degrees)-(-50 degrees) longitude = 332 degrees-l6 degrees and lat.(-46 degrees)-(-52 degrees) long. 360 degrees-60 degrees. Additional maximums diffusion occurs inside radiation belt. Appearance of these maximums seems to be closely connected with preceding powerful solar proton events and associated geomagnetic dynamics of new belt disturbances. Alter the series of solar proton events in June 1991 we observed significant enhancement of this new radiation belt formation. To achieve sufficient accuracy of dose rate predictions in low Earth orbits the structure and dynamics of new belt should be carefully analyzed to be included in a new environment model. From the inter comparison of the data from "Liulin" and French developed tissue equivalent LET spectrometer NAUSICAA in the time period August-November 1992 we come to the following conclusions: Mainly there is good agreement between both data sets for absorbed dose in the region of SAA; Different situation of the instruments on the station can explain the cases when differences up to 2 times are observed; At high latitudes usually the tissue equivalent absorbed dose observations are 2 times larger than "Liulin" doses.