PubMed Health⌕ Search

Biomedical subjects

J F Patrick

Publications and source records attributed to J F Patrick.

26 records · Page 2Linked to original sources

A multiple-electrode hearing prosthesis for cochlea implantation in deaf patients.

A multiple-electrode hearing prosthesis for cochlea implantation in deaf patients has been developed at the University of Melbourne. It has been designed as a multiple-electrode implant to provide the best chance of enabling patients to understand speech. It has been shown that an electrode array can be threaded along the coills of the inner ear close to residual auditory nerves. Experimental studies have indicated that the long-term implantation of the array will not lead to significant degeneration of auditory nerve fibres. Loss of platinum from the stimulating electrodes can be minimized with a biphasic constant current pulse, where the first phase is negative with respect to ground. The receiver-stimulator component has also been designed to provide 10-15 channels of stimulation. Furthermore, the phase and amplitude of the stimuli to individual electrodes can be varied to enable the localization of the electrical fields to discrete groups of nerve fibres, and the correct method of frequency and intensity coding to be determined. Finally, the device should be used in the first instance for a specially selected group of adults who are post-lingually deaf.

Animals↗

A multiple electrode cochlear implant.

The University of Melbourne Departments of Otolaryngology and Electrical Engineering (UMDOLEE) receiving and stimulating component of a multiple-electrode cochlear implant hearing prosthesis produces constant stimulation. It has a stimulating pulse shape that minimizes the production of toxic substances and loss of metal from the electrodes, and this is achieved with a biphasic rectangular waveform where the first phase is negative with respect to ground. The duration of each stimulus phase in 180 msec, which is long enough to allow low levels of current stimulation, and short enough to permit rates of 1000 pulses/second to be achieved. In order to be consistent with our present understanding of the perception of pitch, the device permits the independent stimulation of a number of electrodes. Furthermore, to electrically isolate the stimulus to small areas, there is the capacity to vary the current and set the threshold independently at individual electrodes. The phase and amplitude of the pulses to neighbouring electrodes with also be varied to assist in localizing the current flow. The pattern to stimulation to individual or groups of electrodes can also be altered to enable studies to be carried out to determine ways of conveying frequency and intensity information over a more normal dynamic range.

Animals↗

A multiple-channel cochlear implant and wearable speech-processor: an audiological evaluation.

Stand audiological tests were administered to a totally deaf multiple-channel cochlear implant patient with a wearable speech-processor in a monitored sound field under the following conditions: a wearable unit activated alone (WA), lipreading with the wearable unit off (LA), and wearable unit activated in combination with lipreading (WL). Thresholds obtained for narrow-band noise signals indicated that the wearable unit allowed the patient to detect a variety of sounds at different frequencies. The results obtained in closed-set word tests and open-set word and sentence tests showed significant improvements in word and sentence scores from LA to WL. In the open-set (C.I.D.) sentence test, the patient scored 22% for LA and 76% for WL. The WL score of 76% correlates with a satisfactory performance in understanding connected speech. The patient also scored 30% correct in a test involving the recognition of environmental sounds.

Cochlear Implants↗

A multi-channel hearing prosthesis for profound-to-total hearing loss.

A multi-channel cochlear implant hearing prosthesis providing 22 separate channels of stimulation has been developed. The electronics for the implantable receiver-stimulator have been incorporated on a single chip, using digital circuits and employing CMOS technology. The chip is enclosed in a titanium capsule with platinum/ceramic electrode feed-throughs. A pocket-sized speech processor and directional microphone extract the following speech parameters: signal amplitude, fundamental frequency and formant frequency. The fundamental frequency is coded as electric pulse rate, and formant frequency by electrode position. The speech processor has been realized using hybrid circuits and CMOS gate arrays. The multi-channel prosthesis has undergone a clinical trial on four postlingually deaf patients with profound-total hearing losses. The speech perception results indicate that they were able to obtain open-set speech recognition scores for phonetically balanced words, CID sentences and spondees. In all cases the tests showed significant improvements when using the cochlear prosthesis combined with lipreading compared to lipreading alone.

Adult↗