PubMed Health⌕ Search

Biomedical subjects

J F Patrick

Publications and source records attributed to J F Patrick.

At least 19 recordsLinked to original sources

The Nucleus 22-channel cochlear implant system.

Cochlear implants have become the treatment of choice for profoundly deaf adults and children who obtain little or no benefit from conventional amplification. Sounds are translated into small electric currents that stimulate the auditory nerves in the cochlea and generate hearing sensations. The Nucleus cochlear implant is the result of more than 20 yr of research and development, first at the University of Melbourne, Australia and later by Cochlear Proprietary Limited (Sydney, Australia) in collaboration with the University of Melbourne. Today, the cochlear Mini-22 implant system is approved by the United States Food and Drug Administration (FDA) for use in adults and children, and has been implanted in more than 3000 patients worldwide. Although this chapter describes the cochlear implant system and clinical issues related to its use in children, much of the material has been derived from experience with adults. Furthermore, the Nucleus system is not static. It is being continually improved both in performance and ease of use. The purpose of this chapter is to describe developments leading up to and including the present Nucleus cochlear implant system. Other chapters in this issue present results and procedures relating to pediatric applications of the device.

Adult↗

Implantation of the Melbourne/Cochlear multiple-electrode extracochlear prosthesis.

The Melbourne/Cochlear multiple-electrode extracochlear implant is designed for deaf patients who are unsuited to multiple-electrode intracochlear implantation. The implant consists of a receiver-stimulator package connected via a lead wire assembly to six individual stimulating electrodes. There is a choice of two alternative surgical procedures, both of which are via a combined middle ear approach using anterior and posterior tympanotomies. Four active electrodes shaped into compressible platinum-iridium soft-balls are fed through the mastoid cavity and across the facial recess, and placed into cavities that are made over the cochlear turns that project to the medial wall of the middle ear. One hard-ball active electrode is placed into the round window niche. One hard-ball reference electrode is placed into the hypotympanum. An additional electrode wrapped around the lead wire assembly can be used as an alternative reference electrode. A specially designed insertion needle facilitates the placement and the fixation of the soft-ball electrodes.

Cochlear Implants↗

Computer-controlled 22-channel stimulator for limb movement.

The Nucleus multichannel implantable hearing prosthesis (Nucleus Ltd., Sydney, Australia) has been modified by computer programming (MOCO, Inc., Scituate, Mass.) into a 22-channel neural stimulator for use in functional electrical stimulation (FES). Individual or multiple channels can be sequenced and adjusted for their individual pulse amplitude, width and frequency so that activation of single and multiple nerves can be achieved. Anesthetized rabbits' sciatic nerve branches (lateral and medial) were stimulated to produce single, or co-contraction at the ankle and simultaneous bilateral joint movements. The spiral (helix) electrode was also found suitable in these experiments. In planning for the stimulator's use in paraplegic subjects, information was obtained for human lower extremity peripheral nerves. In 9 patients undergoing lower extremity amputation, threshold and maximal levels of stimulation plus nerve diameters were obtained on 21 nerves. The design for the wearable ambulation unit to control the 22-channel stimulator and electrode tresses with helix electrodes has been completed.

Animals↗

Computerized 22-channel stimulator for limb movement.

The Nucleus 22-channel implantable hearing prosthesis (Cochlear Pty. Ltd., Lane Cove, Sydney, Australia) has been modified by computer programming (MOCO, Inc., Scituate, Mass. USA) into a functional electrical stimulator. Individual or multiple channels can be sequenced and adjusted for their amplitude, width and frequency of the pulse so that activation of single and multiple nerves can be achieved. Sciatic nerve branches (lateral and medial) of anesthetized rabbits were stimulated to produce single contractions or co-contraction at the ankle and simultaneous bilateral joint movements. The spiral (Helix) electrode was also found suitable in these experiments. The external equipment is being re-designed for a wearable ambulation unit to be used in paraplegic subjects.

Animals↗

Recent developments with the nucleus 22-electrode cochlear implant: a new two formant speech coding strategy and its performance in background noise.

A clinical evaluation of speech processing strategies for the Nucleus 22-electrode cochlear implant showed improvements in understanding speech using the new FOF1F2 speech coding strategy instead of the F0F2 strategy. Significant improvement in closed-set speech recognition in the presence of background noise was an additional advantage of the new speech processing strategy.

Cochlear Implants↗

The nucleus multi-channel implantable hearing prosthesis.

The Nucleus Multi-channel Implantable Hearing Prosthesis was developed in conjunction with the University of Melbourne. A 22 channel flexible electrode array is inserted into the cochlea through a round window opening. A cable leads from the electrode array to a demountable connector mounted on the Receiver-Stimulator unit (RSU). A custom CMOS integrated circuit is mounted inside the hermetically sealed titanium and ceramic RSU which is encased in silicone rubber and measures 34.5 mm diameter and 10.5 mm thick. Biphasic current pulse stimuli can be delivered to any selected electrode pairs at rates in excess of 1 kHz. A pocket-sized speech processor extracts spectral information from the incoming acoustic signal, and encodes stimulus information onto the single RF power/data signal transmitted to the RSU through the skin. The Speech Processor includes electronic memory circuits which are programmed with the information mapping acoustic parameters to stimulation parameters for each electrode for each patient. This MAP is established as a result of psychophysical experiments performed by the audiologist using the Diagnostic and Programming System based on a customized microcomputer.

Cochlear Implants↗

A signal processor for a multiple-electrode hearing prosthesis.

A 22-electrode implantable hearing prosthesis uses a wearable speech processor which estimates three speech signal parameters. These are voice pitch, second formant frequency and flattened spectrum amplitude. The signal is monitored continuously for periodicity in the range 80-400 Hz and, if this is present, stimulation occurs at the same rate. Otherwise, as in the case of unvoiced sounds, it occurs at the random rate of fluctuation of the signal envelope. The second formant is obtained by filtering to extract the dominant peak in the midband region and by continuous measurement of the zero crossing rate. The amplitude measured is that of the whole speech spectrum, pre-emphasized by differentiation. The values that are presented to the patient are the parameter estimates immediately prior to the stimulation pulse. Second formant frequency is coded by selection of an appropriate electrode in the cochlea and amplitude by a suitably controlled current. Automatic gain control is used to keep the dynamic range of the amplitude estimate within the 30 dB range of the circuitry.

Cochlear Implants↗

Current distributions in cochlear stimulation.

Animal experimental studies have shown length constants of 2-4 mm for bipolar and 8-16 mm for monopolar stimulations. Studies in models using saline-solution-filled tubes have allowed us to examine the radial and longitudinal current distribution for pseudobipolar stimulation and have demonstrated that current localization is the same for bipolar and pseudobipolar stimulation over a 6-10-dB operating range. With coincident pseudobipolar multiple-channel stimulation there was suppression of the current between the stimulus maxima and enhancement at the edges leading to less stimulus interaction. Experiments performed with a pseudobipolar electrode implanted into the human cochlea showed that there was significant spread of current along the ground electrode because the electrode ground impedance was significantly greater than the cochlear tissue impedances. Because this leads to less current returned at each ground electrode, the pseudobipolar array will result in less interaction for coincident stimulation.

Animals↗

A 12-consonant confusion study on a multiple-channel cochlear implant patient.

A consonant confusion study was undertaken on a multiple-channel cochlear implant patient using a wearable speech processing device. This patient suffered from total bilateral deafness acquired postlingually. The consonants /b/, /p/, /m/, /v/, /f/, /d/, /t/, /n/, /z/, /s/, /g/, /k/ were presented in a VCV context with the vowel /a/ as in father by a male and female speaker under three conditions: lipreading alone; electrical stimulation alone using the wearable speech processor and multiple-channel cochlear implant; lipreading in conjunction with electrical stimulation. No significant difference was detected between the results for the male and female speakers. The percentage correct scores for the pooled results of both speakers were lipreading alone--30%; electrical stimulation alone--48%; lipreading with electrical stimulation--70%. Performance was significantly better for lipreading with electrical stimulation than for lipreading alone and for electrical stimulation alone than for lipreading alone. An information transmission analysis demonstrated the effective integration of visual and auditory information for lipreading with electrical stimulation. There was a significant improvement in performance for the electrical stimulation alone condition over the 2 months of the study in contrast to no such improvement for lipreading alone.

Cochlear Implants↗

A cochlear implant round window electrode array.

This multiple-electrode array for round window cochlear implantation is a robust, reliable system for inserting 20 mm along the scala tympani with a minimum of trauma and can provide for bipolar stimulation.

Cochlea↗