PubMed Health⌕ Search

Biomedical subjects

J Farinas

Publications and source records attributed to J Farinas.

11 recordsLinked to original sources

A microfluidic device for measuring cellular membrane potential.

Recent developments in microfluidics have enabled the design of a lab-on-a-chip system capable of measuring cellular membrane potential. The chip accesses liquid samples sequentially by sipping from a microplate through a capillary, mixes the samples with cells flowing through a microchannel, contacts the cells with potential-sensitive dyes, and reads out cellular responses using fluorescence detection. The rate of cellular uptake of membrane-permeable, ionic fluorophores by THP-1 cells was found to depend strongly on membrane potential. The ratio of the fluorescence of the anionic dye DiBAC(4)(3) and the cationic dye Syto 62 taken up by cells was found to double for every 33 mV change in membrane potential. The utility of this approach was demonstrated by assaying ion channel activity in human T lymphocytes. Because of the high sensitivity, low cellular and reagent consumption, and high data quality obtained with the microfluidic device, the lab-on-a-chip system should be widely applicable in high-throughput screening and functional genomics studies.

Barbiturates↗

Receptor-mediated targeting of fluorescent probes in living cells.

A strategy was developed to label specified sites in living cells with a wide selection of fluorescent or other probes and applied to study pH regulation in Golgi. cDNA transfection was used to target a single-chain antibody to a specified site such as an organelle lumen. The targeted antibody functioned as a high affinity receptor to trap cell-permeable hapten-fluorophore conjugates. Synthesized conjugates of a hapten (4-ethoxymethylene-2-phenyl-2-oxazolin-5-one, phOx) and fluorescent probes (Bodipy Fl, tetramethylrhodamine, fluorescein) were bound with high affinity (approximately 5 nM) and specific localization to the single-chain antibody expressed in the endoplasmic reticulum, Golgi, and plasma membrane of living Chinese hamster ovary cells. Using the pH-sensitive phOx-fluorescein conjugate and ratio imaging microscopy, pH was measured in the lumen of Golgi (pH 6.25 +/- 0.06). Measurements of pH-dependent vacuolar H+/ATPase pump activity and H+ leak in Golgi provided direct evidence that resting Golgi pH is determined by balanced leak-pump kinetics rather than the inability of the H+/ATPase to pump against an electrochemical gradient. Like expression of the green fluorescent protein, the receptor-mediated fluorophore targeting approach permits specific intracellular fluorescence labeling. A significant advantage of the new approach is the ability to target chemical probes with custom-designed spectral and indicator properties.

Adjuvants, Immunologic↗

Green fluorescent protein as a noninvasive intracellular pH indicator.

It was found that the absorbance and fluorescence of green fluorescent protein (GFP) mutants are strongly pH dependent in aqueous solutions and intracellular compartments in living cells. pH titrations of purified recombinant GFP mutants indicated >10-fold reversible changes in absorbance and fluorescence with pKa values of 6.0 (GFP-F64L/S65T), 5.9 (S65T), 6.1 (Y66H), and 4.8 (T203I) with apparent Hill coefficients of 0.7 for Y66H and approximately 1 for the other proteins. For GFP-S65T in aqueous solution in the pH range 5-8, the fluorescence spectral shape, lifetime (2.8 ns), and circular dichroic spectra were pH independent, and fluorescence responded reversibly to a pH change in <1 ms. At lower pH, the fluorescence response was slowed and not completely reversed. These findings suggest that GFP pH sensitivity involves simple protonation events at a pH of >5, but both protonation and conformational changes at lower pH. To evaluate GFP as an intracellular pH indicator, CHO and LLC-PK1 cells were transfected with cDNAs that targeted GFP-F64L/S65T to cytoplasm, mitochondria, Golgi, and endoplasmic reticulum. Calibration procedures were developed to determine the pH dependence of intracellular GFP fluorescence utilizing ionophore combinations (nigericin and CCCP) or digitonin. The pH sensitivity of GFP-F64L/S65T in cytoplasm and organelles was similar to that of purified GFP-F64L/S65T in saline. NH4Cl pulse experiments indicated that intracellular GFP fluorescence responds very rapidly to a pH change. Applications of intracellular GFP were demonstrated, including cytoplasmic and organellar pH measurement, pH regulation, and response of mitochondrial pH to protonophores. The results establish the application of GFP as a targetable, noninvasive indicator of intracellular pH.

Ammonium Chloride↗

Plasma membrane water permeability of cultured cells and epithelia measured by light microscopy with spatial filtering.

A method was developed to measure the osmotic water permeability (Pf) of plasma membranes in cell layers and applied to cells and epithelia expressing molecular water channels. It was found that the integrated intensity of monochromatic light in a phase contrast or dark field microscope was dependent on relative cell volume. For cells of different size and shape (Sf9, MDCK, CHO, A549, tracheal epithelia, BHK), increased cell volume was associated with decreased signal intensity; generally the signal decreased 10-20% for a twofold increase in cell volume. A theory relating signal intensity to relative cell volume was developed based on spatial filtering and changes in optical path length associated with cell volume changes. Theory predictions were confirmed by signal measurements of cell layers bathed in solutions of various osmolarities and refractive indices. The excellent signal-to-noise ratio of the transmitted light detection permitted measurement of cell volume changes of <1%. The method was applied to characterize transfected cells and tissues that natively express water channels. Pf in control Chinese hamster ovary cells was low (0.0012 cm/s at 23 degrees C) and increased more than fourfold upon stable transfection with aquaporins 1, 2, 4, or 5. Pf in apical and basolateral membranes in polarized epithelial cells grown on porous supports was measured. Pfbl and Pfap were 0.0011 and 0.0024 cm/s (MDCK cells), and 0.0039 and 0.0052 cm/s (human tracheal cells) at 23 degrees C. In intact toad urinary bladder, basolateral Pf was 0.036 cm/s and apical membrane Pf after vasopressin stimulation was 0.025 cm/s at 23 degrees C. The results establish light microscopy with spatial filtering as a technically simple and quantitative method to measure water permeability in cell layers and provide the first measurement of the apical and basolateral membrane permeabilities of several important epithelial cell types.

Animals↗

Cell volume and plasma membrane osmotic water permeability in epithelial cell layers measured by interferometry.

The development of strategies to measure plasma membrane osmotic water permeability (Pf) in epithelial cells has been motivated by the identification of a family of molecular water channels. A general approach utilizing interferometry to measure cell shape and volume was developed and applied to measure Pf in cell layers. The method is based on the cell volume dependence of optical path length (OPL) for a light beam passing through the cell. The small changes in OPL were measured by interferometry. A mathematical model was developed to relate the interference signal to cell volume changes for cells of arbitrary shape and size. To validate the model, a Mach-Zehnder interference microscope was used to image OPL in an Madin Darby Canine Kidney (MDCK) cell layer and to reconstruct the three-dimensional cell shape (OPL resolution < lambda/25). As predicted by the model, a doubling of cell volume resulted in a change in OPL that was proportional to the difference in refractive indices between water and the extracellular medium. The time course of relative cell volume in response to an osmotic gradient was computed from serial interference images. To measure cell volume without microscopy and image analysis, a Mach-Zehnder interferometer was constructed in which one of two interfering laser beams passed through a flow chamber containing the cell layer. The interference signal in response to an osmotic gradient was analyzed to quantify the time course of relative cell volume. The calculated MDCK cell plasma membrane Pf of 6.1 x 10(-4) cm/s at 24 degrees C agreed with that obtained by interference microscopy and by a total internal reflection fluorescence method. Interferometry was also applied to measure the apical plasma membrane water permeability of intact toad urinary bladder; Pf increased fivefold after forskolin stimulation to 0.04 cm/s at 23 degrees C. These results establish and validate the application of interferometry to quantify cell volume and osmotic water permeability in cell layers.

Animals↗

Transalveolar osmotic and diffusional water permeability in intact mouse lung measured by a novel surface fluorescence method.

A surface fluorescence method was developed to measure transalveolar transport of water, protons, and solutes in intact perfused lungs. Lungs from c57 mice were removed and perfused via the pulmonary artery (approximately 2 ml/min). The airspace was filled via the trachea with physiological saline containing a membrane-impermeant fluorescent indicator (FITC-dextran or aminonapthalene trisulfonic acid, ANTS). Because fluorescence is detected only near the lung surface due to light absorption by lung tissue, the surface fluorescence signal is directly proportional to indicator concentration. Confocal microscopy confirmed that the fluorescence signal arises from fluorophores in alveoli just beneath the pleural surface. Osmotic water permeability (Pf) was measured from the time course of intraalveolar FITC-dextran fluorescence in response to changes in perfusate osmolality. Transalveolar Pf was 0.017 +/- 0.001 cm/s at 23 degrees C, independent of the solute used to induce osmosis (sucrose, NaCl, urea), independent of osmotic gradient size and direction, weakly temperature dependent (Arrhenius activation energy 5.3 kcal/mol) and inhibited by HgCl2. Pf was not affected by cAMP activation but was decreased by 43% in lung exposed to hyperoxia for 5 d. Diffusional water permeability (Pd) and Pf were measured in the same lung from intraalveolar ANTS fluorescence, which increased by 1.8-fold upon addition of 50% D2O to the perfusate, Pd was 1.3 x 10(-5) cm/s at 23 degrees C. Transalveolar proton transport was measured from FITC-dextran fluorescence upon switching perfusate pH between 7.4 and 5.6; alveolar pH half-equilibrated in 1.9 and 1.0 min without and with HCO3-, respectively. These results indicate high transalveolar water permeability in mouse lung, implicating the involvement of molecular water channels, and establish a quantitative surface fluorescence method to measure water and solute permeabilities in intact lung.

Animals↗

Water transport across mammalian cell membranes.

This review summarizes recent progress in water-transporting mechanisms across cell membranes. Modern biophysical concepts of water transport and new measurement strategies are evaluated. A family of water-transporting proteins (water channels, aquaporins) has been identified, consisting of small hydrophobic proteins expressed widely in epithelial and nonepithelial tissues. The functional properties, genetics, and cellular distributions of these proteins are summarized. The majority of molecular-level information about water-transporting mechanisms comes from studies on CHIP28, a 28-kDa glycoprotein that forms tetramers in membranes; each monomer contains six putative helical domains surrounding a central aqueous pathway and functions independently as a water-selective channel. Only mutations in the vasopressin-sensitive water channel have been shown to cause human disease (non-X-linked congenital nephrogenic diabetes insipidus); the physiological significance of other water channels remains unproven. One mercurial-insensitive water channel has been identified, which has the unique feature of multiple overlapping transcriptional units. Systems for expression of water channel proteins are described, including Xenopus oocytes, mammalian and insect cells, and bacteria. Further work should be directed at elucidation of the role of water channels in normal physiology and disease, molecular analysis of regulatory mechanisms, and water channel structure determination at atomic resolution.

Amino Acid Sequence↗

Constitutive and regulated membrane expression of aquaporin 1 and aquaporin 2 water channels in stably transfected LLC-PK1 epithelial cells.

The aquaporins (AQPs) are a family of homologous water-channel proteins that can be inserted into epithelial cell plasma membranes either constitutively (AQP1) or by regulated exocytosis following vasopressin stimulation (AQP2). LLC-PK1 porcine renal epithelial cells were stably transfected with cDNA encoding AQP2 (tagged with a C-terminal c-Myc epitope) or rat kidney AQP1 cDNA in an expression vector containing a cytomegalovirus promoter. Immunofluorescence staining revealed that AQP1 was mainly localized to the plasma membrane, whereas AQP2 was predominantly located on intracellular vesicles. After treatment with vasopressin or forskolin for 10 min, AQP2 was relocated to the plasma membrane, indicating that this relocation was induced by cAMP. The location of AQP1 did not change. The basal water permeability of AQP1-transfected cells was 2-fold greater than that of nontransfected cells, whereas the permeability of AQP2-transfected cells increased significantly only after vasopressin treatment. Endocytotic uptake of fluorescein isothiocyanate-coupled dextran was stimulated 6-fold by vasopressin in AQP2-transfected cells but was only slightly increased in wild-type or AQP1-transfected cells. This vasopressin-induced endocytosis was inhibited in low-K+ medium, which selectively affects clathrin-mediated endocytosis. These water channel-transfected cells represent an in vitro system that will allow the detailed dissection of mechanisms involved in the processing, targeting, and trafficking of proteins via constitutive versus regulated intracellular transport pathways.

Animals↗

Cell volume measured by total internal reflection microfluorimetry: application to water and solute transport in cells transfected with water channel homologs.

Total internal reflection (TIR) microfluorimetry was established as a method to measure continuously the volume of adherent cells and applied to measure membrane permeabilities in cells transfected with water channel homologs. Cytosol was labeled with the membrane-impermeant fluorophore calcein. Fluorescence was excited by the TIR evanescent field in a thin section of cytosol (approximately 150 nm) adjacent to the cell-substrate interface. Because cytosolic fluorophore number per cell remains constant, the TIR fluorescence signal should be inversely related to cell volume. For small volume changes in Sf-9 and LLC-PK1 cells, relative TIR fluorescence was nearly equal to inverse relative cell volume; deviations from the ideal were modeled theoretically. To measure plasma membrane osmotic water permeability, Pf, the time course of osmotically induced cell volume change was inferred from the TIR fluorescence signal. LLC-PK1 cells expressing the CHIP28 water channel had an HgCl2-sensitive, threefold increase in Pf compared to nontransfected cells (Pf = 0.0043 cm/s at 10 degrees C). Solute permeability was measured from the TIR fluorescence time course in response to solute gradients. Glycerol permeability in Sf-9 cells expressing the water channel homolog GLIP was (1.3 +/- 0.2) x 10(-5) cm/s (22 degrees C), greater than that of (0.36 +/- 0.04) x 10(-5) cm/s (n = 4, p < 0.05) for control cells, indicating functional expression of GLIP. Water and urea permeabilities were similar in GLIP-expressing and control cells. The TIR method should be applicable to the study of water and solute permeabilities and cell volume regulation in cells of arbitrary shape and size.

Animals↗

Structure and function of kidney water channels.

There is now firm evidence that water transporting proteins are expressed in renal and extrarenal tissues. In the kidney, proximal-type (CHIP28) and collecting duct (WCH-CD) water channels have been identified. We have cloned three kidney cDNAs with homology to the water channel (aquaporin) family, including a mercurial-insensitive water channel (MIWC), and a glycerol-transporting protein (GLIP) in collecting duct basolateral membrane. To elucidate water transporting mechanisms, a series of molecular and spectroscopic studies were carried out on purified CHIP28 protein and expressed chimeric and mutated CHIP28 cDNAs. The results indicate that CHIP28 transports water selectively, that CHIP28 monomers are assembled in membranes as tetramers, but that individual monomers function independently. Monomers contain multiple membrane-spanning helical domains. Based on these data and recent electron crystallography results, a model for water transport is proposed in which water moves through narrow pores located within individual CHIP28 monomers.

Amino Acid Sequence↗

Nonpolar environment of tryptophans in erythrocyte water channel CHIP28 determined by fluorescence quenching.

CHIP28 is an abundant water-transporting protein in erythrocytes, kidney proximal tubule, and other fluid-transporting tissues. To determine the environment of the four tryptophans in CHIP28, fluorescence spectra and quenching by polar and nonpolar compounds were measured in stripped human erythrocyte membranes containing CHIP28 and in proteoliposomes reconstituted with purified CHIP28; comparative studies were performed in membranes containing MIP26. Functional analysis showed that CHIP28 water permeability was not affected by the polar quenchers iodide and acrylamide nor the nonpolar n-anthroyloxy fatty acids (n-AF). The emission maximum of CHIP28 tryptophan fluorescence was at 324 +/- 2 nm and did not change with the addition of quenchers; the maximum for MIP26 was at 335 +/- 5 nm. There was weak quenching of CHIP28 tryptophan fluorescence by the polar compounds iodide and acrylamide, with Stern-Volmer constants of 0.13 and 0.71 M-1, respectively. HgCl2 inhibited water permeability by > 95% at 50 microM and quenched CHIP28 fluorescence reversibly by up to 70% with a biphasic concentration dependence; quenching by HgCl2 and acrylamide was not additive. The membrane-associated n-AF probes quenched CHIP28 fluorescence by up to 80% with the greatest quenching for n = 2 and 12; addition of HgCl2 or acrylamide after n-AF caused a small, anthroyloxy-position-dependent increase in quenching which was greatest at n = 6. These studies indicate that the tryptophans in CHIP28 are in a nonpolar, membrane-associated environment. Mathematical modeling of the n-AF results suggests that the tryptophans are clustered near the surface and center of the bilayer.(ABSTRACT TRUNCATED AT 250 WORDS)

Amino Acid Sequence↗