A microfluidic device for measuring cellular membrane potential.

Abstract

Recent developments in microfluidics have enabled the design of a lab-on-a-chip system capable of measuring cellular membrane potential. The chip accesses liquid samples sequentially by sipping from a microplate through a capillary, mixes the samples with cells flowing through a microchannel, contacts the cells with potential-sensitive dyes, and reads out cellular responses using fluorescence detection. The rate of cellular uptake of membrane-permeable, ionic fluorophores by THP-1 cells was found to depend strongly on membrane potential. The ratio of the fluorescence of the anionic dye DiBAC(4)(3) and the cationic dye Syto 62 taken up by cells was found to double for every 33 mV change in membrane potential. The utility of this approach was demonstrated by assaying ion channel activity in human T lymphocytes. Because of the high sensitivity, low cellular and reagent consumption, and high data quality obtained with the microfluidic device, the lab-on-a-chip system should be widely applicable in high-throughput screening and functional genomics studies.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Farinas, A W Chow, H G Wada. 2001-08-15. A microfluidic device for measuring cellular membrane potential.. https://doi.org/10.1006/abio.2001.5202

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Liquid chromatography-mass spectrometry (LC-MS) investigation of the thiobarbituric acid reactive substances (TBARS) reaction.

The thiobarbituric acid reactive substances (TBARS) assay is a commonly used method for the detection of lipid peroxidation. Malondialdehyde is formed as a result of lipid peroxidation and reacts with thiobarbituric acid to form a pink pigment that has an absorption maximum at 532 nm. Other compounds also react with thiobarbituric acid to form colored species that can interfere with this assay, but little is known about these interfering species. This is the first investigation using LC-MS and MS-MS to study the structures of the pink adduct as well as a common unstable yellow interference compound, which absorbs at 455 nm. Also, the presence of barbituric acid impurities in the thiobarbituric acid reagent was found to produce 1:1:1 thiobarbituric acid/malondialdehyde/barbituric acid and 2:1 barbituric acid/malondialdehyde adducts that absorbed at 513 and 490 nm, respectively, indicating that thiobarbituric acid should be purified before use.

Barbiturates↗

Influence of physico-chemical parameters of some barbituric acid derivatives on their retention on an amide embedded RP silica column.

Retention parameters of 45 different barbituric acid derivatives were determined on an amide embedded RP silica column (Discovery RP-AmideC16) using non-buffered water-acetonitrile eluent systems. Linear correlation were calculated between the logarithm of the capacity factor and the acetonitrile concentration in the eluent. To determine the retention behavior of barbituric acid derivatives, stepwise regression analysis (SRA) and principal component analysis (PCA) followed by two-dimensional nonlinear and modified nonlinear mapping was used. It can be concluded, the retention of barbituric acid derivatives are governed mainly by the steric parameters of the substituents. Principal component analysis indicated that the barbituric acid derivatives have mixed retention on this amide embedded RP silica column in water-acetonitrile eluent.

Barbiturates↗