Identification of the source of permanent glare from a three-piece IOL.

OBJECTIVE: To identify the source of unwanted glare images from a three-piece intraocular lens (IOL) implant following cataract surgery. METHOD: The IOL and posterior capsule were examined under mydriatic and nonmydriatic conditions using direct focal illumination from a slit lamp biomicroscope. Direct focal illumination was undertaken with both a narrow beam (0.1 mm in width) and small spot (0.1 mm in diameter) to identify the points at which the glare images were stimulated. While observing the location of the beam with the slit lamp biomicroscope, the patient indicated when the glare images were stimulated. RESULTS: The nasal haptic insertion into the optic was identified as the source of temporal line images arising from lights such as headlamps from oncoming cars and street lamps. The adjacent edge of the IOL was also identified as the likely source of additional cob web-like light rays. CONCLUSIONS: The haptic insertions in three-piece IOLs may, under certain conditions, interfere with light entering the pupil and produce extraneous images. Large mesopic pupils and decentred IOLs are conditions that increase the likelihood of unwanted glare images.

Aged↗

Characterizing reflections from intraocular lens implants.

OBJECTIVE: To develop a test method for characterizing glare from intraocular lenses (IOLs) and to confirm a clinical finding that the haptic insertion in the optic of a three-piece IOL produces extraneous line images. METHOD: The method consists of directing a collimated Gaussian laser beam to various parts of the IOL to be tested in a water-filled model eye. Reflected images produced in the retinal plane are photographed with a digital camera. RESULTS: A test method was developed to characterize the source of glare images from IOLs. The test method developed was used to confirm a clinical finding that the haptic insertion in the optic of a three-piece IOL produces extraneous line images. CONCLUSIONS: The method developed can be used to characterize and pin point the source of extraneous glare images from intraocular lens implants. The haptic insertion in the optic of a three-piece IOL has been identified as a source of line images.

Female↗

Monocular traumatic cataract, extraocular muscle deviation, and intraocular lens implantation.

I report seven patients with monocular traumatic cataract who had either preinjury or postinjury extraocular muscle deviation. All but one were managed with cataract extraction and intraocular lens implantation, without muscle surgery. If muscle surgery is required in such cases, I recommend that it be delayed until at least a year after the cataract and lens implantation surgery.

Adolescent↗

Cortex at the 12 o'clock position and the role of peripheral iris opening.

Performing a peripheral iridectomy is a safe and effective means of atraumatically removing cortex at the 12 o'clock position. It prevents pupillary block as well as adhesions between the iris and capsule. Also, it serves to position the anterior capsular flap and the superior edge of the intraocular lens.

Cataract Extraction↗

A new technique of iridotomy in extracapsular cataract extraction and implantation.

In 1346 consecutive patients undergoing cataract surgery and intraocular lens implantation, we prospectively studied the complications associated with iris iridectomies or iridotomies as compared with those occurring when iris openings were made. We found that the transfixion of the iris with the discission knife is easy, relatively harmless, and prevents a number of complications seen when no iridectomy was performed or if a large iris opening had been made with scissors.

Cataract Extraction↗

Comparison of Healon and Viscoat in cataract extraction and intraocular lens implantation.

Sixty patients were randomly assigned to Healon (20 patients) or Viscoat (40 patients) treatment during extracapsular cataract extraction and intraocular lens implantation surgery. The 40 patients in the Viscoat group were randomly subdivided into two groups. In one group (20 patients), Viscoat was irrigated/aspirated from the eye at the close of surgery, while in the second group of 20 patients, Viscoat was left in the eye. In all Healon cases, the viscoelastic substance was removed from the eye at the end of the surgical procedure. Compared with Viscoat, Healon better facilitated the surgical procedure and appeared to be a more advantageous viscoelastic preparation. Viscoat, in many cases, caused rises in intraocular pressure in the immediate postoperative period when either removed or left in the eye at the close of surgery.

Cataract Extraction↗

Diabetes: cataract extraction and intraocular lenses.

New findings concerning the use of anterior chamber angle-fixated lenses, especially with flexible loops, and posterior chamber lenses placed in the ciliary sulcus and in the bag reinforce previous findings that the safest procedure for diabetics is controlled extracapsular surgery with careful cleaning of the cortical material and in-the-bag implantation of a posterior chamber intraocular lens.

Aged↗

Removal of intraocular lenses: explanation and/or lens exchange.

Removal of intraocular lenses are often performed without adequate reason. I attempted to clarify indications and describe certain methods to remove intraocular lenses safely. I also defined the terminology used in conjunction with intraocular lens removal. (Table).

Humans↗

Use of Healon in different cataract surgery techniques: endothelial cell count study.

The effect of the intracameral application of 1% sodium hyaluronate (Healon) in various cataract extraction techniques was evaluated in four groups of ten cats each whose natural lenses were removed using four different techniques. In a fifth group, the intraocular lenses (IOLs) were implanted over the crystalline lens. Each animal's right eye was treated with Healon and each left eye with balanced salt solution (BSS). Healon-treated eyes lost almost 50% fewer endothelial cells and had a smaller increase in corneal thickness than their counterpart eyes treated with BSS. Lens implantation and phacoemulsification procedures caused the greatest endothelial cell loss, while neodymium YAG laser capsulotomy, a less traumatic procedure, minimized this loss.

Animals↗

The role of 1% sodium hyaluronate in anterior capsulotomy with the neodymium:YAG laser in patients with diseased cornea.

Patients with preexisting corneal pathology who needed cataract extraction had an anterior capsulotomy performed with a Q-switched Nd:YAG laser (LASAG Microruptor II). Thirty-two patients had no sodium hyaluronate (Healon) and 36 patients had Healon injected into the anterior chamber prior to the laser surgery. The non-Healon group had a higher incidence of corneal damage from the YAG laser and, as a result, a higher incidence of endothelial corneal decompensation than the patients with the Healon-filled chamber.

Cataract↗

On-the-table posterior capsulotomy and 1% sodium hyaluronate.

On-the-table posterior capsulotomies were performed in 38 patients with a 30-gauge bent needle behind a bag-fixated posterior chamber J-loop lens with 10-degree angled loops. Ten of the patients (26.30%) developed fluorescein cystoid macular edema (CME) and four patients (10.52%) developed clinical CME within three months. A similar procedure was performed on 36 patients who received 1% sodium hyaluronate (Healon) between the posterior capsule and the vitreous prior to completion of the capsulotomy. One of these patients (2.78%) developed fluorescein CME within three months. In this investigation, no topical indomethacin eyedrops were used. The results seem to indicate that by maintaining a space between the posterior capsule and the anterior hyaloid membrane 1% sodium hyaluronate prevented the development of CME in a significant number of cases. This adds support to the theory that it is the anterior hyaloid membrane that protects the posterior segment of the eye.

Cataract Extraction↗

The role of 1% sodium hyaluronate in treating vitreous incarceration with the neodymium:YAG laser in patients with corneal decompensation.

Thirty-three patients who had corneal damage from the original corneal surgery and incomplete vitrectomy and who had a vitreous incarceration were divided into two groups. In one group, Nd:YAG laser therapy was performed without using a viscoelastic material in the anterior chamber. In the other group, the anterior chamber was filled with 1% sodium hyaluronate (Healon). Postoperative corneal complications were reduced in the group whose anterior chamber had been cushioned. Preoperatively present uveitis cleared upon severing the vitreous incarceration and cystoid macular edema improved in all cases except two in which the cornea decompensated six weeks and six months after the YAG intervention.