PubMed Health⌕ Search

Biomedical subjects

J J Popma

Publications and source records attributed to J J Popma.

At least 145 records · Page 8Linked to original sources

Safety and efficacy of elective stent implantation following rotational atherectomy in large calcified coronary arteries.

Rotational atherectomy is an effective transcatheter therapy for calcified coronary lesions. In large (> 3-mm) calcified coronary arteries, stent implantation following rotational atherectomy may further improve acute and especially, long-term benefit. To determine the safety and efficacy of this device synergy approach, we studied 24 consecutive patients undergoing this procedure electively in native coronary arteries. Procedural success was achieved in 100% without any major ischemic complications. There was also no incidence of subacute thrombosis or cardiac event during 30-day follow-up period. Thus, we conclude that elective stent implantation following rotational atherectomy in large, calcified coronary arteries is safe and results in excellent clinical benefit up to 30 days.

Aged↗

Clinical trials on intracoronary stenting.

The stent is currently taking the lead in the treatment of obstructive coronary artery disease. The interest in this device is not only reflected by the relative number of patients referred for angioplasty and treated with a stent but also by the large number of clinical trials. These can be divided into trials assessing the safety and feasibility of the implantation of second generation or new stents, studies assessing novel treatment strategies and randomized clinical trials. With respect to the latter, they all compare stent implantation with balloon angioplasty. Of major importance will be the comparison of stent implantation with surgical revascularization of obstructive coronary artery disease. The increasing number of therapeutic options, however, confront the physician with the difficult choice and responsibility of selecting the most appropriate treatment. Therefore, systematic and objective evaluation of the available therapeutic approaches by means of appropriately designed trials is imperative. The purpose of this paper is to summarize and to put into perspective the various studies on intracoronary stenting. Distinction is made between observational studies testing a device or evaluating a new concept in intracoronary stenting and randomized clinical trials.

Biocompatible Materials↗

An overview of US coronary stent trials.

Since the introduction of coronary stent procedures in the US there has been a determined effort to understand appropriate clinical applications better through the use of carefully designed prospective clinical trials. These studies fall into the general categories of efficacy studies, pharmacology, studies, intravascular ultrasound studies, adjuvant stent therapy studies, stent versus stent studies and new stent registries. Most of the pivotal clinical trials have been randomized controlled studies, but there have also been several carefully performed registry analyses which have provided useful insights. There are ample data to support the use of stents for abrupt and threatened closure syndrome. STRESS (the STent REStenosis Study) helped to establish the 'anti-restenosis' efficacy of elective Palmaz-Schatz coronary stent placement in native coronary arteries, although secondary complications (subacute stent thrombosis, bleeding and vascular events) were disturbing owing to excessive systemic anticoagulation regimens. Subsequent studies, often using intravascular ultrasound guidance, have clearly indicated that optimal stent implantation requiring post-stent high-pressure dilatations combined with aggressive antiplatelet therapy (aspirin plus ticlopidine) provides the best early and late clinical outcomes. Many of these observations have now been extended to other lesion subsets including saphenous vein grafts. In the future, stent adjuvant therapies will be carefully evaluated, including pharmacological agents, intravascular irradiation, and pre-stent atheroablation. Finally, interstent comparisons of randomized clinical trials are ongoing and there are several new stent registries which will help to extend the frontiers of clinical applications and operator technique.

Angioplasty, Balloon, Coronary↗

Mechanisms of lumen enlargement after excimer laser coronary angioplasty. An intravascular ultrasound study.

BACKGROUND: The mechanisms of excimer laser coronary angioplasty (ELCA) have never been studied in human coronary arteries in vivo. METHODS AND RESULTS: ELCA was used to treat 202 lesions in 190 patients. Forty-nine lesions in 48 patients were studied by use of sequential (before and after ELCA and after adjunctive device therapy) intravascular ultrasound (IVUS). External elastic membrane (EEM), lumen, and plaque+media (P+M = EEM-lumen) cross-sectional areas (CSAs) and lesion arcs of calcium were measured before and after ELCA and after adjunct device use. Lumen improvement after ELCA (1.4 +/- 0.5 to 2.7 +/- 0.8 mm2) was the result of both tissue ablation (decrease in P+M CSA from 16.8 +/- 7.1 to 15.9 +/- 6.7 mm2, P < .0001) and vessel expansion (increase in EEM CSA from 18.2 +/- 7.1 to 18.6 +/- 6.8 mm2, P = .0245), with no change in calcium. The decrease in P+M CSA was 39% of the CSA of the laser catheter used. Dissections were present in 39% of lesions, 84% within superficial calcium; fibrocalcific deposits developed a "fragmented" appearance. CONCLUSIONS: ELCA increased lumen CSA by both atheroablation and vessel expansion without calcium ablation. Superficial fibrocalcific deposits developed a characteristic fragmented appearance. These findings support both photoablation and forced vessel expansion as mechanisms of lumen enlargement and plaque dissection after ELCA.

Angioplasty, Balloon, Coronary↗

Coronary lumen at six-month follow-up of a new radiopaque Cordis tantalum stent using quantitative angiography and intracoronary ultrasound.

To determine the reliability of geometric (edge-detection) quantitative coronary angiographic analysis (QCA) of restenosis within a new Cordis tantalum stent, QCA and intracoronary ultrasound (ICUS) measurements were compared in both an experimental restenosis model and in the clinical follow-up of patients. In the experimental series, Plexiglas phantom vessels with concentric stenosis channels ranging from 0.75 to 3.0 mm in diameter and with a reference diameter of 3.0 mm were imaged both before and after their insertion in tantalum stents. In the clinical series, the agreement of QCA and ICUS measurements were studied in 23 patients who had undergone coronary implantation of the new tantalum stent and in 23 patients who had undergone balloon angioplasty 6 months previously. The reliability of QCA declined in the presence of the radiopaque stent (accuracy of QCA decreased from -0.07 to -0.12 mm), whereas the reliability of lumen measurements by ICUS was independent of the presence of the radiopaque stent (-0.12 and -0.13 mm). Without the stent, the average minimal luminal diameter (MLD) obtained by QCA of the 1.00 mm Plexiglas vessel was 1.00 +/- 0.01 mm, and the 3.00 mm reference vessel diameter was 2.81 +/- 0.05 mm, providing a 64 +/- 1% diameter stenosis. After introduction of the stent, the average MLD and reference vessel diameter were 0.99 +/- 0.06 and 3.36 +/- 0.17 mm, respectively, providing a diameter stenosis of 71 +/- 2%. ICUS measurements (2.77 mm) of the reference vessel diameter (3.00 mm) were unaffected by the presence of the stent.(ABSTRACT TRUNCATED AT 250 WORDS)

Coronary Angiography↗

Patterns of calcification in coronary artery disease. A statistical analysis of intravascular ultrasound and coronary angiography in 1155 lesions.

BACKGROUND: Target lesion calcium is a marker for significant coronary artery disease and a determinant of the success of transcatheter therapy. METHODS AND RESULTS: Eleven hundred fifty-five native vessel target lesions in 1117 patients were studied by intravascular ultrasound (IVUS) and coronary angiography. The presence, magnitude, location, and distribution of IVUS calcium were analyzed and compared with the detection and classification (none/mild, moderate, and severe) by angiography. Angiography detected calcium in 440 of 1155 lesions (38%): 306 (26%) moderate calcium and 134 (12%) severe. IVUS detected lesion calcium in 841 of 1155 (73%, P < .0001 versus angiography). The mean arc of lesion calcium measured 115 +/- 110 degrees; the mean length measured 3.5 +/- 3.7 mm. Target lesion calcium was only superficial in 48%, only deep in 28%, and both superficial and deep in 24%. The mean arc of superficial calcium measured 85 +/- 108 degrees; the mean length measured 2.4 +/- 3.4 mm. Three hundred seventy-three of 1155 reference segments (32%) contained calcium (P < .0001 compared with lesion site). The mean arc of reference calcium measured 42 +/- 80 degrees; the mean length measured 1.7 +/- 3.6 mm. Only 44 (4%) had reference calcium in the absence of lesion calcium. Angiographic detection and classification of calcium depended on arcs, lengths, location, and distribution of lesion and reference segment calcium. By discriminant analysis, the classification function for predicting angiographic calcium included the arc of target lesion calcium, the arc of superficial calcium, the length of reference segment calcium, and the location of calcium within the lesion. This model correctly predicted the angiographic detection of calcification in 74.4% of lesions and the angiographic classification (none/moderate/severe) of calcium in 62.8% of lesions. CONCLUSIONS: IVUS detected calcium in > 70% of lesions, significantly more often than standard angiography. Although angiography is moderately sensitive for the detection of extensive lesion calcium (sensitivity, 60% and 85% for three- and four-quadrant calcium, respectively), it is less sensitive for the presence of milder degrees.

Calcinosis↗

Comparison of clinical and angiographic outcomes after saphenous vein graft angioplasty using coronary versus 'biliary' tubular slotted stents.

BACKGROUND: Saphenous vein graft (SVG) angioplasty using 15-mm articulated, tubular slotted stents results in low (0% to 20%) residual diameter stenoses and infrequent (< 5%) major complications. A "biliary" stent design with greater radial compressive strength, enhanced visibility, and more variable sizing (diameter and length) has been approved for noncoronary indications. A comparison of outcomes after coronary versus biliary stent placement in SVG stenoses has not been performed. The purpose of this study was to compare the angiographic and clinical results after SVG angioplasty using these two balloon-expandable, tubular slotted stent designs. METHODS AND RESULTS: During a 3-year period, 231 patients with 305 SVG lesions were treated using Palmaz-Schatz coronary (n = 108) or biliary (n = 123) stents. Cineangiograms were reviewed using qualitative morphological and quantitative angiographic methods. Time-dependent clinical outcome (freedom from death, Q-wave myocardial infarction, or the need for repeat coronary bypass surgery or SVG angioplasty) was assessed using Kaplan-Meier life-table methods. Unstable angina (P < .001) and recent myocardial infarction (P = .001) were present more often in patients undergoing biliary stent versus coronary stent placement. Biliary stent-treated SVG lesions were more frequently de novo (P = .001), ostial in location (P = .002), > or = 10 mm in length (P = .009), thrombus containing (P = .001), and ulcerated (P < .001) than coronary stent-treated SVG lesions. Angiographically, biliary stent-treated lesions had larger reference vessel diameter (3.43 +/- 0.59 mm versus 3.10 +/- 0.64 mm, P < .001), higher balloon-to-artery ratio (1.15 +/- 0.16 mm versus 1.07 +/- 0.19, P = .0001), and lower residual diameter stenosis (6 +/- 17% versus 14 +/- 11% in coronary stent-treated patients; P < .001). Procedural success rates were high (95%), in-hospital major complications were uncommon (< 3%), and follow-up clinical outcomes were favorable (6-month event-free survival approximately 80%) in both groups. CONCLUSIONS: Despite frequent short-term ischemic syndromes and unfavorable lesion characteristics, both biliary and coronary cohorts have similarly favorable short-term procedural results and long-term clinical outcomes. The increased strut thickness of the biliary stent confers greater fluoroscopic visibility and radial compressive strength in exchange for decreased stent flexibility and added technical demand in stent deployment. Extreme caution is recommended with biliary stent placement in the treatment of SVG lesions as clinical results are highly operator dependent.

Aged↗

Can coronary flow parameters after stent placement predict restenosis?

Intracoronary stent was used to treat a dissection resulting from balloon angioplasty. Coronary flow parameters measured with Doppler Flowire pre- and post-stenting suggested abnormal coronary flow even after stenting. The patient returned 4 months later with an instent restenosis. This case suggests the intriguing possibility of coronary flow parameters obtained immediately after new device angioplasty in predicting restenosis.

Aortic Dissection↗

Multivariate predictors of intravascular ultrasound end points after directional coronary atherectomy.

OBJECTIVES: This study attempted to identify the clinical, angiographic, procedural and intravascular ultrasound predictors of directional atherectomy results assessed by intravascular ultrasound. BACKGROUND: Several angiographic and intravascular ultrasound variables have been associated with the outcome of directional coronary atherectomy. No study has incorporated both modalities into a predictive model. METHODS: One hundred seventy patients were analyzed using preintervention and postintervention intravascular ultrasound and quantitative angiography. Clinical and procedural variables were collected by independent chart review. Quantitative and qualitative angiographic analysis was performed by a core laboratory in blinded manner. Intravascular ultrasound was performed using a transducer-tipped catheter, rotating within a stationary imaging sheath, and withdrawn automatically at 0.5 mm/s. Clinical, procedural, angiographic and ultrasound variables were tested in a multivariate linear regression model. Dependent ultrasound variables included postatherectomy lumen cross-sectional area and percent cross-sectional narrowing (plaque plus media/external elastic membrane cross-sectional area) and, in a subgroup of 47 patients studied using volumetric analysis, percent plaque volume removal. RESULTS: By multivariate stepwise linear regression analysis, predictors of residual lumen cross-sectional area (correcting for reference lumen area) included arc of calcium and preatherectomy plaque plus media cross-sectional area; predictors of residual cross-sectional narrowing were arc of calcium, preatherectomy plaque plus media cross-sectional area and lesion length; and predictors of percent plaque volume removal were arc of calcium and atherectomy device size. CONCLUSIONS: The preintervention lesion arc of calcium measured by intravascular ultrasound is the most consistent predictor of the effectiveness and results of directional coronary atherectomy.

Atherectomy, Coronary↗

Atherosclerosis in angiographically "normal" coronary artery reference segments: an intravascular ultrasound study with clinical correlations.

OBJECTIVES: This study evaluated the magnitude, patterns and clinical correlates of atherosclerosis in angiographically "normal" reference segments in patients undergoing transcatheter therapy for symptomatic coronary artery disease. BACKGROUND: Pathologic studies indicate that the extent of coronary atherosclerosis is underestimated by visual analysis of angiographically normal coronary artery segments. Intravascular ultrasound allows detailed, high quality cross-sectional imaging of the coronary arteries in vivo. METHODS: Intravascular ultrasound was used to study angiographically normal coronary artery reference segments in 884 patients evaluated for transcatheter therapy for symptomatic native coronary artery disease. The reference segment was the most visually normal intravascular ultrasound cross section within 10 mm proximal to the target lesion but distal to any major side branch. Results are presented as mean value +/- 1 SD. RESULTS: Only 60 (6.8%) of 884 angiographically normal reference segments were normal by intravascular ultrasound. Reference segment percent cross-sectional narrowing measured 51 +/- 13% and correlated poorly with the target lesion percent cross-sectional narrowing (r = 0.166, p < 0.0001). Reference segments contained less calcific and dense fibrotic plaque and proportionately more soft plaque elements. Independent predictors of reference segment percent cross-sectional narrowing were male gender, patient age, diabetes mellitus, hypercholesterolemia and presence of multivessel disease. Independent predictors of reference segment calcification were patient age and serum creatinine levels. Reference segment percent cross-sectional narrowing in 723 patients undergoing transcatheter therapy was similar to that in patients studied for diagnostic purposes; however, reference segment arc of calcium was greater in treated patients (43 +/- 81 vs. 25 +/- 57, p = 0.015). Reference segment disease was not an independent predictor of subsequent angiographic restenosis or clinical events within 12 months of follow-up. CONCLUSIONS: Atherosclerosis is ubiquitous in angiographically normal coronary artery reference segments. Reference segment disease parallels the severity of target lesion disease and is associated with many of the conventional risk factors for coronary artery disease. Because of its sensitivity in detecting atherosclerosis in angiographically normal reference segments, intravascular ultrasound should enhance the study of risk factors for atherosclerosis and the results of therapies to control disease progression.

Age Factors↗