Small stent size and intimal hyperplasia contribute to restenosis: a volumetric intravascular ultrasound analysis.

OBJECTIVES: The purpose of this study was to use volumetric intravascular ultrasound analysis of Palmaz-Schatz stents to assess the in-stent restenotic process. BACKGROUND: By reducing lesion elastic recoil and chronic arterial remodeling, stents improve the long-term results of coronary angioplasty. However, stents are prone to the development of neointimal hyperplasia. Angiographic studies of stent restenosis have suggested that these hyperplastic responses are the cause of in-stent restenosis; however, it is difficult to visualize the radiolucent Palmaz-Schatz stent by angiography. Intravascular ultrasound provides detailed cross-sectional imaging of the coronary arteries, especially the intense metallic reflection of endovascular stents. METHODS: Forty-four patients with 60 Palmaz-Schatz stents underwent intravascular ultrasound imaging at follow-up ([mean +/- SD] 8.8 +/- 7.2 months after implantation). Thirty-four stents were placed in saphenous vein grafts and 26 in native coronary arteries; 30 were placed in restenotic lesions. Intravascular ultrasound with automatic transducer pullback at 0.5 mm/s allowed measurement of stent, lumen and intimal hyperplasia cross-sectional areas at 1-mm axial increments within the stents. Using Simpson's rule, stent, lumen and intimal hyperplasia volumes were calculated. Patterns of in-stent restenosis were then identified. RESULTS: Restenotic stents had smaller stent volumes (120 +/- 41 vs. 147 +/- 43 mm3, p = 0.016) and lumen volumes (62 +/- 28 vs. 118 +/- 42 mm3, p < 0.0001) but larger intimal hyperplasia volumes (58 +/- 36 vs. 29 +/- 18 mm3, p < 0.001) than nonrestenotic stents. A focal restenosis pattern was more common (20 [77%] of 26) than a diffuse restenosis pattern (6 [23%] of 26). Stents with focal restenosis and stents with diffuse restenosis had equally small stent volumes (120 +/- 44 vs. 120 +/- 31 mm3, respectively, p = NS); however, stents with diffuse restenosis had larger intimal hyperplasia volumes (84 +/- 30 vs. 50 +/- 34 mm3, p < 0.05). Focal restenosis was most commonly located at the central articulation (45%); the location of focal restenosis was related to the focal accumulation of neointimal tissue. CONCLUSIONS: Stent volume and magnitude and distribution of intimal hyperplasia are important in the development of in-stent restenosis. Stent volume was smaller and intimal hyperplasia volume greater in restenotic stents. Stent restenosis is more commonly focal in nature and located at the central articulation.

Aged↗

A modified directional atherectomy catheter for resection of calcified atherosclerotic plaques.

BACKGROUND: The purpose of this study was to determine the feasibility of resecting calcified atherosclerotic plaques in human cadaveric vessels by using a modified directional coronary atherectomy catheter and to correlate these results with bench tests using an in-vitro sea coral model. METHODS: The conventional directional coronary atherectomy catheter was modified by changing the cutter blade to a tungsten carbide material and by increasing the torsional strength of the drive cable. The performance of the modified directional coronary atherectomy (DCA) catheter was compared with the conventional catheter using a sea coral model to simulate calcified material. Then, 10 human ex-vivo arteries (eight with calcification) were treated with both conventional and modified catheters, and the results studied with intravascular ultrasound and confirmed by histologic examination. RESULTS: Using the modified directional coronary atherectomy catheter it was possible to perform effective and consistent longitudinal cutting, and to resect a significantly larger amount of coral (1.0 +/- 0.1 mm2 versus 0.2 +/- 0.1 mm2 with conventional cutter, P < 0.0001). In heavily calcified ex-vivo arteries, the modified catheter was more effective in removing calcified plaques (13 +/- 11 mg versus 3.7 +/- 1.4 mg with conventional cutter, P = 0.07). Intravascular ultrasound confirmed the effective atherectomy (residual area stenosis 28 +/- 16% versus 47 +/- 10% with the conventional device, P < 0.05), and histologic examination showed calcified nodules in the atherectomy samples obtained with the modified cutter (area of calcium 1.43 +/- 0.89 mm2 versus 0.93 +/- 0.83 mm2 with the conventional cutter). CONCLUSIONS: The modified directional coronary atherectomy catheter effectively removed both non-calcified and calcified plaques in the ex-vivo human cadaveric arteries, thus demonstrating the feasibility of directional coronary atherectomy of calcified plaques. This modified device shows promise for treating calcified coronary lesions, especially in larger vessels.

Animals↗

The contribution of tissue removal to lumen improvement after directional coronary atherectomy.

The contribution of tissue removal to lumen improvement after directional coronary atherectomy remains controversial. The purpose of this study was to validate the intravascular ultrasound measurement of plaque volume and use it to study the contribution of tissue removal to lumen improvement after directional coronary atherectomy. With use of intravascular ultrasound, 12 human coronary vessels were imaged in vitro. With use of computer-assisted planimetry, the external elastic membrane and lumen cross-sectional areas were manually traced and the plaque+media area was calculated at 1 mm axial intervals. Then, plaque+media volume was calculated by Simpson's rule. After imaging, ultrasound measurements of plaque+media volume were compared with histologic measurements. Similarly, volumetric intravascular ultrasound imaging was performed before and after directional atherectomy in 47 patients. In vitro, the mean plaque+media volume measured by intravascular ultrasound was 134.0 +/- 94.8 mm3 and compared well with that derived by histology (187.4 +/- 128.8 mm3, r = 0.96, p < 0.001). In vivo, the lumen volume increased from 27.2 +/- 12.3 to 58.7 +/- 30.3 mm3, and the mean plaque+media volume decreased from 122.0 +/- 74.0 to 97.5 +/- 63.5 mm3. The mean intravascular ultrasound atherectomy index was 76 +/- 23%. In 11 of the 47 patients (23.4%), tissue removal alone accounted for lumen improvement. Volumetric intravascular ultrasound image analysis indicates that the mechanism of directional coronary atherectomy primarily is tissue removal. As a result, the contribution of arterial remodeling (expansion and dissection) probably is less important.

Aged↗

Limitations of angiography for analyzing coronary atherosclerosis progression or regression.

PURPOSE: To analyze the utility and limitations of serial coronary angiography for determining atherosclerosis progression and regression. DATA SOURCES: A MEDLINE search of the English-language literature (1966 to January 1994) using the keywords atherosclerosis regression, atherosclerosis progression, lipid reduction therapy, and coronary angiography. STUDY SELECTION: Selected articles on the effects of cholesterol reduction and lifestyle modification on angiographic coronary artery disease, on the animal models of atherosclerosis progression and regression, and on the limitations of coronary angiography. DATA EXTRACTION: Independent extraction by two authors. RESULTS: Although several studies have reported that the rate of atherosclerosis progression, defined by serial coronary angiography, can be reduced and that luminal diameter can be improved somewhat by aggressive lipid modification, the reported changes are small (0.3 mm or 10% change) and have required a prolonged study duration (range, 1 to 10 years). More importantly, angiography simply does not measure atherosclerosis and cannot assess lesion composition. Angiography also underestimates the extent of atherosclerosis, especially in angiographically normal segments. In addition, difficulties with data acquisition, such as substantial variabilities in serial measurements of percent diameter stenosis and minimal luminal diameters, require large sample sizes to show statistically significant regression, even with computerized quantification. CONCLUSIONS: Given its current limitations, serial coronary angiography is not a satisfactory means of detecting atherosclerosis progression or regression.

Anticholesteremic Agents↗

Impact of preintervention intravascular ultrasound imaging on transcatheter treatment strategies in coronary artery disease.

Preintervention intravascular ultrasound (IVUS) imaging was performed in 313 target lesions in 301 patients. Revascularization strategy intended before imaging was compared with the treatment actually performed; there was a change in therapy in 124 lesions (40%) in 121 patients (40%). This included: (1) assessment of lesion severity leading to revascularization when none had been planned (n = 20, 6%), (2) avoiding surgery or catheter-based revascularization that had originally been planned (n = 21, 7%), and (3) assessment of lesion composition leading to a change in revascularization strategy (n = 20, 6%) or for selecting the revascularization strategy (n = 63, 20%). Nine of these 121 patients were referred for coronary artery bypass graft surgery. IVUS minimal lumen diameter correlated well with angiography (r = 0.83); however, a disagreement was the reason for deciding to perform or not to perform revascularization in 41 lesions (13%). IVUS assessment of target lesion calcification, eccentricity and unusual morphology were the reasons for changing or selecting specific devices: (1) concentric and eccentric lesions with significant superficial calcium were treated with rotational atherectomy, excimer laser angioplasty or surgery; (2) eccentric lesions that did not contain significant superficial calcium were treated with directional atherectomy; (3) dissections and true aneurysms were treated with stent placement even if calcified; (4) thrombus-containing lesions in vein grafts were treated with thrombolytic therapy or extraction atherectomy, or both; and (5) fibrotic vein graft lesions were treated with balloon angioplasty or stent placement.

Adult↗

A dual-purpose angioplasty-drug infusion catheter for the treatment of intragraft thrombus.

An investigational angioplasty-drug infusion catheter (Transport, CardioVascular Dynamics, Irvine, CA) was used to treat a saphenous vein graft stenosis associated with a thrombus. The catheter was successfully used both to infuse urokinase at the site of angioplasty and to perform effective angioplasty, demonstrating the feasibility and utility of a dual-purpose angioplasty catheter capable of angioplasty and/or local drug infusion with the same catheter.

Angioplasty, Balloon, Coronary↗

Coronary artery lumen volume measurement using three-dimensional intravascular ultrasound: validation of a new technique.

OBJECTIVE: To validate an automated algorithm for the measurement of lumen volumes of coronary arteries. BACKGROUND: Current intravascular ultrasound systems use absolute measurements of and changes in areas and diameters for the assessment of coronary artery disease. However, the coronary artery is a three-dimensional structure of complex geometry and volume. METHODS: We used a comprehensive imaging system designed to reconstruct planar intravascular ultrasound images in three dimensions. This system consisted of a 25 MHz transducer-tipped rigid probe (for in vitro studies) or a 25 MHz transducer-tipped catheter within a 3.9F monorail imaging sheath (for in vivo studies), a motorized catheter pullback device that withdrew the transducer at 0.5 mm/sec, and an image processing computer that stacked 15 image slices/mm of vessel axial length and then performed threshold-based three-dimensional image rendering and lumen volume measurement. We imaged 13 human coronary vessels (6 RCA, 6 LAD, 1 LCX) in vitro and 16 vessels (8 LAD, 6 RCA, 2 SVG) in vivo. RESULTS IN VITRO STUDIES: Lumen volumes derived by three-dimensional intravascular ultrasound were 171 +/- 121 mm3 and compared very well with those derived by histology (160 +/- 109 mm3, r = 0.97, SEE = 29 mm3, P < 0.001) and with those derived by manual planimetry of planar intravascular ultrasound images (150 +/- 106 mm3, r = 0.97, SEE = 30 mm3, P < 0.001). In vivo studies: Lumen volumes derived by three-dimensional intravascular ultrasound were 74 +/- 35 mm3 and compared well with those derived by quantitative angiography (52 +/- 20 mm3, r = 0.71, SEE = 25 mm3, P < 0.002). CONCLUSIONS: Three-dimensional intravascular ultrasound is a new technique that can accurately measure coronary artery lumen volumes. Further technical improvements may help to establish this technique as the new standard for lumen volume measurement.

Adult↗

Clinical significance of distal embolization after transluminal extraction atherectomy in diffusely diseased saphenous vein grafts.

Standard balloon angioplasty of degenerated saphenous vein graft lesions may be complicated by distal embolization, particularly in the presence of intragraft thrombus. Transluminal extraction atherectomy may be useful in this setting because of its ability to remove particulate debris. This study was designed to identify the incidence and prognostic significance of distal embolization after transluminal extraction atherectomy in high-risk saphenous vein graft lesions. To address these issues the clinical course of 65 consecutive patients (86 high-risk saphenous vein graft lesions) was reviewed after extraction atherectomy. Distal embolization occurred in 11 (12.8%) of 86 high-risk lesions. The majority (63.6%) of these episodes occurred after adjunct balloon dilatation following uncomplicated use of the extraction atherectomy catheter. Correlates of distal embolization included patient age and the presence of intragraft thrombus. Major in-hospital complications developed more often in patients with distal embolization (46% vs 2% in those without distal embolization, p < 0.001), resulting in a reduced procedural success rate in this group (55% vs 91%, p = 0.01). We conclude that the risk of distal embolization after saphenous vein graft angioplasty, although potentially reduced, is not eliminated with transluminal extraction atherectomy, particularly in lesions with superimposed thrombus.

Aged↗

Relation of clinical presentation, stenosis morphology, and operator technique to the procedural results of rotational atherectomy and rotational atherectomy-facilitated angioplasty.

BACKGROUND: Rotational atherectomy using the Rotablator has recently become available to treat coronary stenoses. This study was performed to determine the relation of patient characteristics, stenosis morphology, and operator technique to procedural outcome to gain insight into which patients might be best treated with this device. METHODS AND RESULTS: Four hundred stenoses from 316 patients randomly selected from the initial Rotablator experience at three major referral institutions were analyzed. Angiographic data were assessed at a central angiographic laboratory using standardized morphological criteria and caliper measurement. Patients were somewhat more elderly than most percutaneous transluminal coronary angioplasty (PTCA)-treated groups (mean age, 64 +/- 11 years), 74% were men, and the lesions treated were often complex (modified American College of Cardiology/American Heart Association lesion type A, 24%; B1, 40%; B2, 30%; and C, 6%). Elective adjunctive PTCA was used for 82% of stenoses treated. Procedural success was achieved in 89.8% of stenoses (93.5% if results with creatine kinase two to three times normal are not counted as failures), and major ischemic complications (death, 0.3%; non-Q-wave myocardial infarction, 5.7%; Q-wave myocardial infarction, 2.2%; or emergency bypass surgery, 0.9%) occurred in 8.9% of patients. Complications were due to epicardial coronary obstruction in 3.8% of patients and to delayed coronary runoff ("slow reflow") in 5.1% of patients. Procedural failure was correlated independently with outflow obstruction (success rate, 64%; odds ratio for failure, 5.4; multivariate P = .002), lesion irregularity (76%; odds ratio, 3.3; P = .003), stenosis bend > or = 60 degrees (73%; odds ratio, 3.7; P = .03), and female sex (84%; odds ratio, 2.4; P = .03). Ischemic complications were correlated independently with lesion length (> or = 50% narrowing) > or = 4 mm (complication rate, 12%; odds ratio, 3.6; multivariate P = .005), right coronary artery stenosis (13%; odds ratio, 2.4; P = .02), stenosis bend > or = 60 degrees (27%; odds ratio, 6.1; P = .03), and female sex (13%; odds ratio, 3.0; P = .04). Slow reflow was correlated with total burring duration (odds ratio, 1.005/s; multivariate P = .001), right coronary artery stenosis (incidence, 17%; odds ratio, 4.5; P = .009), and to a lesser extent with recent myocardial infarction in the treated territory (44%; odds ratio, 4.3; P = .08). CONCLUSIONS: The procedural outcome of rotational atherectomy is highly correlated with stenosis morphology and location and sex of the patient. After stratification for these parameters, overall outcome with the Rotablator appears to be similar to that with balloon angioplasty and other competing techniques. Short-term outcome with specific subsets of patients may be superior with the Rotablator (calcified stenoses), but this technique might best be avoided in some patients (those with irregular or possibly thrombus-containing stenoses, highly angulated stenoses, and possible right coronary artery stenoses or those associated with impaired distal runoff caused by a recent myocardial infarction or manifest by a fixed thallium defect).

Aged↗

Increased coronary perforation in the new device era. Incidence, classification, management, and outcome.

BACKGROUND: The incidence of coronary perforation using new percutaneous revascularization techniques may be increased compared with PTCA. Still, perforation is uncommonly reported, and the optimal management and expected outcome remain unknown. The objectives of the study were to determine the incidence of coronary perforation using balloon angioplasty (percutaneous transluminal coronary angioplasty, PTCA) and new revascularization techniques and to develop optimal strategies for its management based on classification and outcome. METHODS AND RESULTS: Eleven sites with frequent use of new revascularization devices and prospective coding of consecutive procedures for coronary perforation during 1990 to 1991 contributed to a perforation registry. Patients with perforation were matched by device with an equal-sized cohort without perforation. Data were collected centrally, and all procedural cineangiograms were reviewed at a core angiographic laboratory. A classification scheme based on angiographic appearance of the perforation (I, extraluminal crater without extravasation; II, pericardial or myocardial blushing; III, perforation > or = 1-mm diameter with contrast streaming; and cavity spilling) was evaluated as a predictor of outcome and as a basis for management. Perforation was observed in 62 of 12,900 procedures reported (0.5%; 95% confidence interval, 0.4% to 0.6%), more commonly with devices intended to remove or ablate tissue (atherectomy, laser) than with PTCA (1.3%, 0.9% to 1.6% versus 0.1%, 0.1% to 0.1%; P < .001). The perforation population was notable for its advanced age (67 +/- 10 years) and high incidence of female sex (46%) (both P < .001 compared with patients without perforation). Perforation could be treated expectantly or with PTCA but without cardiac surgery in 85%, 90%, and 44% of class I, II, and III perforations, respectively. Class I perforations (n = 13, 21%) were associated with death in none, myocardial infarction in none, and tamponade in 8%. The incidences of these adverse events were 0%, 14%, and 13% in class II perforations (n = 31, 50%) and 19%, 50%, and 63% in non-cavity spilling class III perforations, respectively (n = 16, 26%). Two of the 15 instances of cardiac tamponade (13%) were delayed, occurring within 24 hours after dismissal from the catheterization laboratory. CONCLUSION: The incidence of perforation, while low, is increased with new devices. Women and the elderly are at highest risk. The clinical risk after perforation can be classified angiographically, but even low-risk perforations occasionally have poor clinical outcome. Patients should be observed for delayed cardiac tamponade for at least 24 hours.

Aged↗

Early and late clinical outcome following coronary angioplasty performed with platelet glycoprotein IIb/IIIa receptor inhibition: the EPIC Trial results.

Ischemic complications complicate coronary angioplasty in 10-20% of patients. Antithrombotic agents, such as aspirin and heparin, reduce the frequency of peri-procedural complications, but their effect is incomplete. A chimeric (mouse and human) monoclonal antibody (c7E3 Fab) has been developed, which is a specific inhibitor of the platelet glycoprotein IIb/IIIa receptor and prevents platelet-to-platelet aggregation. A randomized study of 2099 patients at "high-risk" for complications after coronary angioplasty has demonstrated a 35% reduction in 30-day ischemic complications resulting from bolus (0.25 mg/kg) and 12-hour infusion (10 micrograms/min) of c7E3 Fab (8.3% in c7E3 Fab-treated patients versus 12.8% in placebo-treated patients; p = 0.008). The highest reduction in ischemic complications was noted in patients presenting with acute myocardial infarction or unstable angina (hazard ratio = 0.5; 95% confidence intervals [CI]: 0.3-0.9) compared with those patients with high-risk anatomy alone (hazard ratio = 0.7; 95% CI: 0.5-1.1). Late (6-month) clinical events were also lower in patients undergoing successful coronary angioplasty (event-free at 48 hours) who treated with bolus and infusion c7E3 Fab (19.2% versus 25.4% in placebo-treated patients; p = 0.007). The beneficial effect of c7E3 Fab on reducing ischemic complications after coronary angioplasty was balanced by a doubling of major bleeding complications in c7E3 Fab-treated patients (14% versus 7% in placebo-treated patients; p = 0.001). Bleeding complications appear to be related to the intensity of peri-procedural anticoagulation using nonweight adjusted heparin. These results suggest that bolus and 12-hour infusion of c7E3 Fab is a valuable pharmacologic adjunct to reduce peri-procedural complications in "high-risk" patients undergoing coronary angioplasty, particularly in those patients with myocardial infarction or unstable angina. Further studies are underway to develop alternative heparin dosing strategies in an effort to reduce the occurrence of bleeding complications associated with c7E3 Fab administration and to assess the benefit of c7E3 Fab-mediated platelet inhibition in lower risk patient subgroups.

Abciximab↗

Primary coronary angioplasty in patients with acute myocardial infarction.

In some patients with acute myocardial infarction, thrombolytic therapy may be limited by its failure to reperfuse the occluded artery, by recurrent ischemia (despite initially successful reperfusion), and by major hemorrhagic complications. Primary coronary angioplasty may circumvent these limitations. This article reviews the results of primary angioplasty reported in patients with myocardial infarction and makes recommendations for its use. The review includes pertinent articles found in the English language literature from July 1987 to July 1993 on MEDLINE. Nonrandomized series of primary angioplasty in acute myocardial infarction have demonstrated high procedural success rates (86% to 99%) and infrequent recurrent ischemia (4%). Two randomized trials comparing primary angioplasty and thrombolytic therapy have shown that primary angioplasty results in lower mortality, less recurrent ischemia, shorter length of hospital stay, and improved left ventricular function. Two other randomized studies have shown little benefit from primary angioplasty on myocardial salvage, recurrent ischemia, or ventricular function. One major limitation of primary angioplasty is that it requires 24-hour availability of a catheterization laboratory and experienced surgical personnel. Primary angioplasty may be the preferred approach in patients with extensive myocardial infarction who have immediate (< 120 min) access to a cardiac catheterization laboratory with experienced personnel. Patients having 1) contraindications to thrombolytic therapy, 2) cardiogenic shock, 3) prior coronary bypass surgery, or 4) "stuttering" onset of pain may also benefit from primary angioplasty. Poor candidates for this procedure are those with a small myocardial infarction, those in whom undue delays in access to a cardiac catheterization facility would be expected, or those with complex coronary anatomy, including left main coronary artery disease.

Angioplasty, Balloon, Coronary↗

Clinical and angiographic outcome after directional coronary atherectomy. A qualitative and quantitative analysis using coronary arteriography and intravascular ultrasound.

To assess clinical and angiographic outcome after directional coronary atherectomy, the clinical course of 306 patients undergoing this procedure was reviewed. Directional atherectomy was successful in 290 (94.8%) procedures; complications developed in 8 (2.6%) patients. After atherectomy, percent diameter stenosis was reduced from 71 +/- 14 to 14 +/- 14% (p < 0.001) and minimal lumen diameter was increased from 0.87 +/- 0.42 to 2.55 +/- 0.57 mm (p < 0.001). In 128 (42%) patients, adjunct balloon angioplasty was performed to treat either complications or a residual stenosis > 30%. Intravascular ultrasound was also performed in 57 patients after directional atherectomy and demonstrated that a significant amount of residual plaque mass remained in lesions with a calcium arc > or = 90 degrees (17 +/- 5 mm2 vs 12 +/- 5 mm2 in lesions without calcium; p = 0.007). During the 11 +/- 6 month follow-up period, 69 (28.3%) patients developed recurrent clinical events (death, 5; Q wave myocardial infarction, 8; coronary bypass surgery, 31; coronary angioplasty, 36). Using a proportional hazards model, independent predictors of late clinical events included diabetes mellitus (relative risk [RR] = 1.95; p < 0.05), unstable angina (RR = 2.78; p < 0.005) and a prior history of restenosis (RR = 2.21; p < 0.01). We conclude that directional atherectomy is associated with high procedural success rates and infrequent complications in selected lesions subsets, although the degree of plaque resection may be limited if extensive calcium is present. Late clinical events develop in some (28%) patients after directional atherectomy, related to certain preprocedural clinical risk factors.

Atherectomy, Coronary↗

Rotational coronary atherectomy after unsuccessful coronary balloon angioplasty.

The clinical and angiographic outcome of patients undergoing rotational coronary atherectomy after unsuccessful balloon angioplasty was evaluated using quantitative angiographic methods to provide insight into this procedure's mechanism of benefit. During the study period, 41 patients (50 lesions) were referred for rotational atherectomy after standard balloon angioplasty was unsuccessful. After rotational atherectomy, percent diameter stenosis was reduced from 72 +/- 14% to 41 +/- 16% (p < 0.001); adjunct balloon angioplasty was performed in 44 lesions (88%), resulting in a 25 +/- 17% final diameter stenosis (p < 0.001). The acute gain in minimal lumen diameter was 1.20 +/- 0.59 mm. In lesions needing adjunct balloon dilatation, lesion stretch was 73 +/- 27%, and elastic recoil was 22 +/- 18%, with no variation by etiology of the initial balloon failure. Overall angiographic success (< 50% residual diameter stenosis) was obtained in 49 lesions (98%). Procedural success, defined as < 50% residual diameter stenosis and the absence of major in-hospital complications (death, Q-wave myocardial infarction or emergency bypass surgery), was obtained in 37 of 41 procedures (90%); complications developed in 3 patients (7%), including 2 who needed emergency bypass surgery after development of delayed abrupt closure. It is concluded that rotational coronary atherectomy may be used in selected patients when standard balloon angioplasty is unsuccessful. Its mechanism of benefit appears related, at least in part, to changes in plaque compliance resulting from partial atheroma ablation.

Angioplasty, Balloon, Coronary↗