PubMed Health⌕ Search

Biomedical subjects

J Kohn

Publications and source records attributed to J Kohn.

At least 55 records · Page 3Linked to original sources

Trends in the development of bioresorbable polymers for medical applications.

The gradual shift from biostable prostheses to degradable, temporary implants represents one of the most significant trends in biomaterials research. In view of this trend, medical applications of degradable implant materials were reviewed with special emphasis on orthopedic polymeric implants. Among the polymeric implant materials derived from natural sources, collagen, various polysaccharides such as cellulose, and microbial polyesters have been intensively investigated. Among the synthetic, degradable polymers, aliphatic polyesters such as poly(glycolic acid), poly(lactic acid), poly(caprolactone) and polydioxanone, are most commonly investigated. Only recently, several new classes of polymers such as poly(ortho esters), polyanhydrides, and degradable polycarbonates have been introduced as potential implant materials. A particularly versatile group of new biomaterials with promising engineering properties are the "pseudo"-poly(amino acids), amino acid derived polymers in which conventional peptide bonds have been replaced by various chemical linkages.

Absorption↗

Tissue compatibility of tyrosine-derived polycarbonates and polyiminocarbonates: an initial evaluation.

Compression-molded disks of two tyrosine-derived polymers [poly(desaminotyrosyl-tyrosine-hexyl ester carbonate) and poly(desaminotyrosyl-tyrosine hexyl ester iminocarbonate)], two polymers derived from Bisphenol A [poly(Bisphenol A iminocarbonate) and poly(Bisphenol A N-phenyliminocarbonate)], and two clinically used standard materials [poly(D,L-lactic acid) and high-density polyethylene] were implanted subcutaneously in the back of Sprague-Dawley rats. The tissue response elicited by these materials was evaluated histologically at 7, 30, and 120 days postimplantation, based on the total cell density (including fibroblasts, monocytes, giant cells, and macrophages) at the implantation site. The tissue response observed for the two tyrosine-derived polymers was mild, comparable to the two standard materials, medical-grade poly(L-lactic acid) and high density polyethylene. The two Bisphenol A-containing polymers elicited significantly more severe tissue responses. These results indicate that the use of derivatives of the natural amino acid L-tyrosine in the synthesis of degradable implant materials improved the tissue compatibility of these materials relative to chemically related polymers that contain Bisphenol A, an industrial diphenol. The tyrosine-derived polyiminocarbonate and polycarbonate are therefore promising candidates for a detailed evaluation of their biocompatibility, including long-term implantation studies in higher mammals.

Animals↗

Physico-mechanical properties of degradable polymers used in medical applications: a comparative study.

The physico-mechanical properties of degradable polymers used for medical applications have been characterized. The following polymers were included in this study: three samples of poly(ortho esters) derived from 3,9-bis(ethylidene 2,4,8,10-tetraoxaspiro[5,5]undecane) and various ratios of 1,6-hexanediol and trans-cyclohexane dimethanol, poly(glycolic acid), six samples of poly(L-lactic acid) and poly(D,L-lactic acid) with mol wt from 21,000 to 550,000, poly(epsilon-caprolactone), poly(beta-hydroxybutyrate) and three copolymers of beta-hydroxybutyric acid and various amounts of hydroxyvaleric acid, one sample each of two different types of poly(anhydrides), poly(trimethylene carbonate) and two different poly(imino-carbonates). For each polymer, the thermal properties (glass transition temperature, crystallization, melting and decomposition points) were determined by differential scanning calorimetry and by thermogravimetric analysis. The tensile properties (Young's modulus, tensile strength and elongation at yield and break) were determined by tensile testing on an Instron stress-strain tester. The flexural storage modulus as a function of temperature was determined by dynamic mechanical analysis.

Anhydrides↗

Patient factors and the influence of nephrologists, social workers, and nurses on patient decisions to choose continuous peritoneal dialysis.

To determine which members of the health care team are viewed by ESRD patients as the most helpful in giving information and deciding on a dialysis modality, we surveyed 42 outpatients after they toured the dialysis facility. The tour included discussions with a social worker, PD and HD nurses, watching a videotape, and receipt of written materials. Nephrologists referred patients for tours. Multiple responses were accepted. Patients felt that social workers (70%) and nurses (71%) gave the most useful information. Fifty per cent of patients thought the nurse, 43% the social worker, 21% the nephrologist, and 21% family or friend most helpful in deciding on PD versus HD. Twenty-three patients chose PD, 16 chose in-center HD. Patients choosing PD were more likely to be white (20/29 versus 3/10, p less than 0.05) and employed (11/23 versus 3/16 choosing HD, p less than 0.10). Patients choosing PD were also better educated but this was not independent of race. No differences in gender, age, or the presence of diabetes were seen among those choosing PD versus HD. Social workers and nurses are more influential than nephrologists in helping patients select a dialysis modality. PD patient recruitment efforts should focus on social workers' and nurses' input.

Decision Making↗

Structure-property relationships for the design of polyiminocarbonates.

Structure-property relationships for the design of new polyiminocarbonates were established, based on the investigation of thermal stability and processibility, morphology, tensile strength, hydrolytic degradation and drug release profiles of 15 different polyiminocarbonates. The results indicated that some polyiminocarbonates were among the mechanically strongest, bioerodible polymers currently available. The iminocarbonate bond was highly unstable under physiological conditions, facilitating the design of rapidly degrading devices. The drug-release profiles of certain polyiminocarbonates exhibited lag periods, facilitating the design of pulsed-release or delayed-release devices. Possible limitations of the practical applicability of polyiminocarbonates as biomaterials were the low thermal stability of the iminocarbonate linkage and the complicated, two-phase degradation mechanism that led to the formation of slowly degrading residues of low molecular weight. To identify non-toxic diphenols as monomers for the synthesis of polyiminocarbonates, derivatives of tyrosine dipeptide were systematically explored. Using structure-property relationships as design guidelines, desaminotyrosyl-tyrosine hexyl ester was identified as a promising, tyrosine-derived diphenol. The corresponding poly(desaminotyrosyl-tyrosine hexyl ester iminocarbonate) formed amorphous, transparent films and was mouldable at about 70 degrees C. It had a tensile strength of 400 kg/cm2 and a tensile modulus of 16,300 kg/cm2. Under physiological conditions in vitro, a thin film made of high molecular weight poly(desaminotyrosyl-tyrosine hexyl ester iminocarbonate) degraded to low molecular weight oligomers within 5 d. The results indicated that polyiminocarbonates and in particular poly(desaminotyrosyl-tyrosine hexyl ester iminocarbonate) might be of interest in a variety of biomedical applications.

Animals↗

Single-step immunization using a controlled release, biodegradable polymer with sustained adjuvant activity.

The use of a biodegradable polymer for antigen delivery based on poly(CTTH-iminocarbonate) (IUPAC nomenclature: poly[oxyimidocarbonyloxy-p-phenylene [2-(hexyloxycarbonyl)ethylene]imino[2-[1-(benzyloxy)formamido]- 1-oxotrimethylene]-p-phenylene]) was investigated. This polymer was selected since its primary degradation product, N-benzyloxycarbonyl-L-tyrosyl-L-tyrosine hexyl ester (CTTH) was found to be as potent an adjuvant as complete Freund's adjuvant and muramyl dipeptide, when measuring the serum antibody response to bovine serum albumin (BSA) in male CD-1 mice over 56 weeks. BSA released from subcutaneously implanted polymeric antigen delivery devices made of poly(CTTH-iminocarbonate) resulted in significantly higher (P less than 0.006) anti-BSA antibody titers than devices made of poly(bisphenol A-iminocarbonate).

Adjuvants, Immunologic↗

Poly(iminocarbonates) as potential biomaterials.

Poly(iminocarbonates), based on diphenols such as hydroquinone or Bisphenol A were synthesized. Poly(iminocarbonates) degraded under physiological conditions. Compression moulded discs of poly-(hydroquinone-iminocarbonate) showed near zero-order release for low loadings (1%, w/w) of Eosin Y. Poly(Bisphenol A-iminocarbonate) formed transparent films and strong fibres. It is a tough polymer with high tensile strength. Under physiological conditions complete erosion of a thin film of poly(Bisphenol A-iminocarbonate) required about 200 d. The release profile for p-nitroaniline from solvent cast films of poly(Bisphenol A-iminocarbonate) was characterized by a lag period (20 d), followed by near zero-order release for 90 d. Initial toxicological studies revealed no inflammatory cell response after implantation in the corneas of rabbits or subcutaneously in mice.

Animals↗

The use of alkaline-phosphatase conjugated second antibody for the enhancement of immunoprecipitation techniques on cellulose acetate membranes.

A technique is described using alkaline phosphatase (ALP) conjugated second antibodies on cellulose acetate membrane (CAM) for enhancement of immunoprecipitation techniques. The method is extremely sensitive, detecting as little as 0.1 mg/l of protein and has particular application in the investigation of monoclonal immunoglobulins in human serum or urine and in hybridoma supernatants or ascitic fluids.

Alkaline Phosphatase↗