Mode of failure of the Mitroflow pericardial valve.

A consecutive series of 188 Mitroflow pericardial bioprostheses were inserted in 166 patients between 1st January 1983 and 31st December 1985. Twenty-two valves had to be removed from 16 patients after a mean follow up period of 78 months (range 58-92 months) for aortic, 73 months (65-79 months) for mitral and 78 months (48-103 months) for double valve replacements. All but one reoperations for primary tissue failure were carried out as elective surgical procedures. The most important cause of failure was collagen degeneration, seen in all explanted valves. The areas of degeneration were the major sites of origin of calcification, which was seen in 11 valves (50%). Ten valves (45%) showed features suggestive of lipid infiltration, extensive fatty acid deposition being identified in one and a typical atheromatous reaction in another. In contrast to the Ionescu-Shiley valve, the mode of failure was tear originating at the top of the commissure, associated with major structural changes in the tissue. Excessive pannus ingrowth was observed in 11 valves (50%). The universal presence of tissue degeneration in the glutaraldehyde treated pericardial leaflets of the Mitroflow bioprostheses explanted and examined in this study questions the adequacy of the methods employed in the harvesting and/or processing and/or preservation of this valve. We have, therefore, discontinued using the Mitroflow bioprosthesis. However, the slow deterioration of the Mitroflow bioprosthesis permits elective reoperation; preventive removal of functioning valves is therefore not indicated.

Adult

In vitro endothelialization of carbon-coated Dacron vascular grafts.

Physical vapour deposition is used to coat vascular prostheses with pyrolytic carbon. This coating may facilitate the development of an endothelial monolayer in grafts implanted in laboratory animals. This in vitro study compared the adherence and growth of cultured porcine aortic endothelial cells (EC) seeded in vitro on carbon-coated Dacron, to uncoated prostheses. The cells were incubated at 5 x 10(4) cells/cm2. Progress was monitored at different times (TO + 2 hours, D 1, D 4, D 8) by microscopic observation, when cell counts were made; and by scanning electronic microscopy (SEM) to evaluate morphological EC-graft interactions. Cell adherence was independent of the carbon coating but cellular growth occurred only on carbon-coated Dacron. The SEM observations showed both the shape of the adherent cells, which were rounded on uncoated Dacron and extensively spread on carbon-coated prostheses, and the morphology of the carbon coating.

Blood Vessel Prosthesis

Enhanced O2 transportation during cardiopulmonary bypass in piglets by the use of inositol hexaphosphate loaded red blood cells.

A continuous lysing and resealing of erythrocytes permitted internalization of inositol hexaphosphate (IHP), a strong allosteric effector of Hb, leading to significant rightward shifts of the HbO2 dissociation curve. Twelve piglets were put on cardiopulmonary bypass (CPB) with the heart beating, cooled to 25 degrees C then rewarmed to 37 degrees C before weaning off CPB. AoP, LV pressure, PAP, and cardiac output (CO) were monitored. Blood samples were taken before CPB, at 25 degrees C, at 30 degrees C, at 37 degrees C and after CPB for assessment of blood gases, arterio-venous difference in O2 content, lactates, P50 (partial pressure of O2 at 50% Hb saturation), and ionogram. Control group I included five pigs where the CPB circuit was primed with Ringer's lactate solution and porcine blood. In group II (n = 5), priming was done with Ringer's lactate solution and IHP loaded erythrocytes. P50 was significantly higher during CPB than before surgery in group II (20%), but not in group I (1%). There was a significant increase in VO2 in group II (6.02 ml/min) compared to group I (4.03 ml/min) (p less than 0.05) after CPB. Hemodynamics improved after CPB in group II (mean AoP 42 mmHg and syst LVP 70 mmHg) compared to group I (AoP 25 mmHg and syst LVP 22.5 mmHg). These preliminary results show that O2 transportation at the end of CPB is enhanced and myocardial function is improved in piglets with the use of IHP erythrocytes.

Animals

[Conflicting xenograft. Role of preoperative total lymphoid irradiation].

This study deals with an experimental model of discordant cardiac xenograft between 24 donor lambs of the Préalpes race and 24 recipient Camborough pigs divided up into 4 groups: I control (6) without immunosuppressive treatment; II (5) with pharmacological immunosuppression (IP); III (13) with PI and total lymphoid irradiation (TLI) and immediate graft, divided up into IIIa (5) with high-rate (HR) TLI and IIIb with low-rate (LR) TLI; IV (4) with a two-week lapse between TLI and grafting. The best graft survival rate (GSR) is obtained either after delayed LR-TLI or after LR-TLI without delay. This study seems to be the first one demonstrating that for discordant xenogenic grafts, TLI associated to PI with cyclosporin A (Cy A) significantly prolongs the survival of the graft (30 times).

Animals

[Experimental study of arterial microanastomoses under tension in the Wistar rat. Morphologic and histologic effects].

An experimental study was performed to evaluate the effects of tension on microsurgical anastomoses. A variable length of the common carotid artery in Wistar rats was resected to give variable degrees of tension and the artery was reanastomosed microsurgically. 42 Wistar rats were divided into 7 groups of 6 rats each according to the relative length resected. Repaired arteries were then compared histologically and functionally with the artery of the contralateral side, submitted to simple section followed by microsurgical anastomosis. Significant histological changes occurred when the length of the resected segment was greater than 13.33% of the vessel's total length. These changes included subendothelial hyperplasia, medial necrosis and thrombosis. The results of this study lead us to conclude that small degrees of tension (less than 13.33% of total vessel length in this study), have no significant effects on patency of microanastomoses. Greater tension results in changes in the laminar flow through vessels that can adversely effect patency. There are also significant histological changes that may have detrimental effects in the long term.

Anastomosis, Surgical

[New surgical procedure for the protection of the small intestine before postoperative pelvic irradiation].

A prosthesis was designed to protect the intestinal loop from external beam radiation therapy when post-operative radiation is indicated. It is a silicone inflatable balloon, which, when implanted displaces the intestinal loops out of the pelvic irradiation field. The prosthesis can be deflated between each course of irradiation, without surgery. The device has been used in 8 patients: 6 patients with recurrent pelvic tumor (2 rectal cancers, 1 anal cancer, 1 cancer of the endometrium, 1 cervical carcinoma, 1 ovarian carcinoma), 2 patients with primary tumor (1 malignant paraganglioma, 1 cervical carcinoma). Radiotherapy was administered by means of high power appliances. After radiotherapy, the prosthesis was deflated, then removed through a 3 cm incision under local or peridural anesthesia. The tolerance of the small intestine to the radiation therapy has been satisfactory in each case with no bowel injury due to radiation. Therefore, this simple device might be useful to prevent bowel injury during postoperative radiation in the treatment of abdominal and retroperitoneal tumor masses.

Combined Modality Therapy

Centrifugal pump or pneumatic ventricle for short-term mechanical circulatory support?

Two comparable groups of four Holstein calves were implanted with different left ventricle assist devices: the Centrimed centrifugal pump (CP) (Sarns Inc.) or the UTAH 85 VAD pneumatic ventricle (University of Utah). Operative procedure, inflow and outflow cannulae, monitoring, heparinization, were identical in both groups. No transfusion was ever required. The study was terminated after three days and autopsy was performed on the calves. Left ventricular unloading provided by both devices was complete (LVEDP less than 1 mmHg) and identical. LV bypassed flow rate was higher in CP (0.045 L/min/kg) than in UTAH 85 VAD (0.035 L/min/kg) but with no statistical difference. Blood trauma was comparable in the two groups. Daily blood samples did not show any significant changes from baseline values in creatinine, hematocrit, fibrinogen. Platelet loss from initial level was 30%; serum lactate dehydrogenase rose 150% with no significant difference in the two groups; plasma free hemoglobin never reached significant values. At autopsy, thrombotic deposits on cannuale and renal infarction rate were similar. CP housing had to be changed every day, whereas no technical failure was ever observed with the UTAH 85 VAD. Clinical response and blood damage of the two pumps used as LVAD were the same. Considering the CP has to be replaced every 24 h, the cost of three CP's would be comparable to one Utah UVAD-85 if polyurethane tricusp semi-lunar valves are used in the latter. Until the UTAH-85 VAD becomes commercially available, simple valveless low-cost CP are very attractive for short-term mechanical support.

Animals

[Intubation of proximal biliary stenoses using a new surgical endoprosthesis].

Thirty patients with high biliary tract strictures were treated by a new surgical endoprosthesis, the tolerance of which has been tested experimentally. It is flexible, radiopaque and incompressible with spurs which prevent migration. Following choledochotomy, the endoprosthesis is positioned surgically above the sphincter of Oddi, thereby avoiding ascending cholangitis. Twenty-nine cases presented with neoplastic compression by an inoperable cancer and one case had an early postoperative stricture with loss of substance after right hepatectomy for hepatic metastases. The 29 cancers included 13 gallbladder cancers, 11 cholangiocarcinomas, 10 of which were hilar, and 5 metastatic compressions due to gastrointestinal adenocarcinomas. In three cases, there was loss of substance of biliary tract after intubation. The operative mortality was 3.3% (one pulmonary complication). Resolution of jaundice was obtained in all but 2 cases and pruritus always resolved. The mean survival of the patients with cholangiocarcinoma was 12.2 months while that of patients with gallbladder cancer was 6.33 months with indices of satisfaction, calculated by Bismuth's method, varying between 71% (gallbladder cancer) and 93.5% (hilar cholangiocarcinoma). The patient operated for benign stricture secondary to a hepatectomy scar for metastases died from lung metastases without jaundice after 48 months. The only late complications were 2 cases of cholangitis treated medically, one of which was due to obstruction of the endoprosthesis at the 13th month. The authors conclude that this new type of surgical endoprosthesis constitutes an alternative in the palliative treatment of neoplastic hilar compressions.

Cholestasis

[Cystoplasty using a resorbable polyglactin prosthesis covered by a free peritoneal flap].

The bowel is not always suitable for cystoplasty. The use of a vicryl mesh lined with a peritoneal flap was investigated as material for partial replacement of the bladder. The procedure was performed on 20 rats divided into two groups. A partial cystectomy was first performed, then a cystoplasty was done using either a free peritoneal flap (group 1) or a vicryl mesh combined with a peritoneal flap (group 2). The results were evaluated using intravenous pyelography, macroscopic examination and histological analysis within one month. In group 1 (7 cases), there was one urinary fistula. In group 2 (13 cases), no fistula was observed but stones occurred in three cases. The histological analysis revealed good reconstruction of urothelium in both groups. Partial resorption of vicryl was observed at one month with organization of neo-muscular fibers. The vicryl prosthesis was well accepted and, when covered by a peritoneal flap, provided a strong and water-tight material for bladder replacement. The vicryl mesh increased the risk of stone formation in the presence of urinary tract infection.

Animals

Myocardial revascularization by CO2 laser.

An original method of myocardial revascularization using CO2 laser has been studied in a pig model with acute myocardial infarction. Transparietal channels were created by myocardial vaporization, using a CO2 laser beam. A comparative evaluation was made against a control group using as parameters survival rate, ECG changes, anatomopathologic findings, and angiographic studies. With the exception of favorable changes in the ECG there was no other evidence of improved regional perfusion. No evidence of long-term patency of the transmyocardial channels could be demonstrated by angiographic and histologic studies.

Animals

Arterial healing in rabbits following carbon dioxide laser endarterectomy.

CO2 laser open endarterectomy of small atherosclerotic vessels appears feasible. Under the conditions described, the endarterectomized arterial wall is not smooth but the thrombogenicity of the laser-treated surface is low, and the endothelial healing rapid. These advantages are to be weighed against the consequence of thermal injury, in particular, the late development of aneurysms. Before human clinical trials are made, further experimental studies are required to determine the best type of laser and optimal wave length to limit thermal injury.

Animals

[Reconstructive microsurgery of the vas deferens. Experimental study of suture materials].

Microsurgery is the procedure of choice for vasectomy reversal. The aim of this study was two compare two different suture materials for vasovasectomy - a nonresorbable material (nylon 10/0 with a BV 6 needle), which is widely used, and a resorbable material (polyglycolic acid, also with a BV 6 needle), which has not yet been evaluated for this use. 28 Sprague-Dawley rats were operated on under microscope. Two groups were then compared, group A with nylon (n = 14) and group B with polyglycolic acid (n = 14). In each group, 8 animals had a vas deferens section and 6 had a previous vasectomy by ligature. Ten days postoperatively, the patency rate of the anastomosis was evaluated by the presence of sperm on both sides of the suture line. The contractility was assessed by mechanical stimulation. The existence of a sperm granuloma was considered as indicative of a non functional anastomosis. Three days later a fertility test was performed, lasting three months, and the number of litters was checked. The rats were sacrificed after three months, and each vas deferens was examined histologically or by electron microscope. The macroscopic results were: 57% patent anastomoses in group A and 77% in group B. 16% patent anastomoses after ligature in group A (n = 6) and 75% in group B (n = 6). The pregnancy rate was 54% in group A and 77% in group B. After previous ligation, the corresponding figures were 20% and 83% respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals

Fetal breathing and adaptation to maternal hemorrhage in the sheep.

The effect of maternal hemorrhage in chronic preparations was studied on fetal lambs in the last month of gestation. Fourteen to 20 per cent of maternal blood was estimated to have been removed within 30 minutes, which resulted in a drop of 30 per cent of mean maternal arterial pressure. A fetal bradycardia started 28 +/- 13 minutes after the beginning of maternal hemorrhage. It lasted 30 +/- 15 minutes and was concomitant with a rise in fetal arterial pressure. It was followed by a long-lasting fetal tachycardia of 130 +/- 38 minutes and was corrected only by reinfusion of blood to the mother. The fetal blood gases demonstrated a mild asphyxia with a persistent metabolic acidemia until reinfusion of blood to the mother. Maternal and fetal plasma cortisol levels rose significantly at the end of the hemorrhage. Tracheal fluid flow did not change. Fetal breathing recorded 20 hours before and 24 hours after the experiment did not show consistent changes, but during fetal bradycardia there was no fetal breathing. Recent clinical investigations in this field have been made in the human fetus to estimate standards of fetal well being. These peculiar animal experiments do not show any significant improvement by recording fetal breathing over the recording of prelabor fetal heart rate.

Adaptation, Physiological