Publications and source records attributed to J M Hasenkam.

At least 19 recordsLinked to original sources

Increased expression of endothelin B receptor in static stretch exposed porcine mitral valve leaflets.

The aim of this study was to evaluate the effect of mechanical stretch on the expression of ET-1 and ET(A)- and ET(B)-receptors in porcine mitral valve leaflets. Leaflet segments from 10 porcine mitral valves were exposed to a static stretch load of 1.5 N for 3.5h in buffer at 37 degrees C together with matching control segments. Subsequently, the mRNA expression of ET-1, ET(A)-R and ET(B)-R was measured by real-time RT-PCR in the chordal insertion areas. The analyses showed an increased transcription of ET(B)-receptors in stretch-exposed leaflet segments compared to unstretched segments median 2.23 (quartiles 1.37 and 2.70) vs. median 1.56 (quartiles 1.38 and 2.17, P=0.03) whereas the mRNA expression of ET(A)-receptors (P=0.90) and ET-1 (P=0.51) remained unchanged. Stretch increased the expression of ET(B)-receptors in porcine mitral valve leaflets. The finding could lead to a better understanding of the pathogenesis of myxomatous mitral valve disease.

Animals↗

Postoperative treatment with low molecular weight heparin after right heart assist for coronary artery bypass grafting.

Right heart assist (RHA) was used for coronary artery bypass grafting (CABG). We explored the affection of the coagulation system during surgery and evaluated two different antithrombotic treatments postoperatively. The pilot study comprised 14 patients. During surgery activated clotting time (ACT) was kept > 200 sec. By random the patients were selected to different postoperative treatments. The control group received acetyl salicylic acid (ASA) 150 mg daily, the intervention group received ASA 150 mg daily and Low Molecular Weight Heparin (LMWH) 5000 IU x2 for three days. Serum levels of prothrombin fragment 1 and 2 (F 1 + 2), plasmin-antiplasmin product (PAP), anti-Xa activity and functional antithrombin (ATIII) were measured. During surgery there was no increase of F 1 + 2 or PAP. After protamin was administered there was a significant increase of F 1 + 2 but not in PAP during the next 6 hours. Postoperative antithrombotic treatment with LMWH seems to normalise F1 + 2 while ASA does not. ACT level > 200 sec. seems sufficient for RHA-CABG surgery. Fibrinolytic agents are not necessary. It seems that postoperative LMWH treatment prevents increased thrombin formation. General recommendations with respect to antithrombotic treatment beyond ASA can not be made based on study.

Adult↗

Evaluation of a novel method for measuring tissue blood flow and gases.

In clinical practice a method for assessment of tissue vitality is a sought-after tool. We have developed a new sensor principle, which is able to register changes in tissue concentration of O2 and tissue flow. The technique is based on diffusion of inert gases and mass spectrometer detection of gaseous metabolites. It was hypothesized that the new sensor could register changes in vital parameters after induction and release of an ischaemic insult to muscular tissue. The sensor performance was evaluated in ten anaesthetized pigs subjected to local muscular ischaemia. Preliminary data from this study indicate the validity of registered hypoxia and reduction in tissue flow as a consequence of compromised blood supply. It was concluded that although precise calibration of the technique is not yet established, it holds promise as a technique that can be used to monitor changes in tissue vitality.

Animals↗

Right heart assist for beating heart coronary artery bypass grafting.

OBJECTIVE: Cardiopulmonary bypass used in conventional coronary artery bypass surgery (cCABG) entails a risk of complications. Consequently, the trend is moving towards off-pump coronary artery bypass (OPCAB). This procedure, however, may lead to haemodynamic instability due to kinking of the right ventricle when the posterior aspect of the heart is exposed. The aim of the study was to establish if a right-sided circulatory assist device (RHA) was able to maintain haemodynamic stability during OPCAB procedures. METHOD: In a prospective study 50 RHA-OPCAB patients and a control group of 50 cCABG patients were examined. Before accessing the marginal arteries, an RHA was established in the RHA-OPCAB patients. RESULTS: A stable haemodynamic condition was achieved for 98% of the RHA-OPCAB patients. The study group had less postoperative chest drain bleeding (P<0.001), shorter ventilation time (P=0.001), and lower blood levels of creatine kinase (CK) and brain CK (P<0.001) compared to the control group. CONCLUSION: The results indicate that RHA-OPCAB is a realistic alternative to cCABG. The procedure can be safely performed most likely resulting in reduced postoperative bleeding, myocardial damage, and ventilation time.

Adult↗

Edge-to-edge mitral repair: tension on the approximating suture and leaflet deformation during acute ischemic mitral regurgitation in the ovine heart.

BACKGROUND: Edge-to-edge approximation of the mitral valve leaflets (Alfieri procedure) is a novel surgical treatment for patients with ischemic mitral regurgitation (IMR). Long-term durability may be limited if abnormal mitral leaflet stresses result from this procedure. The aim of the current study was to measure Alfieri stitch tension (F(A)) and to explore its geometric determinants in an ovine model of acute IMR as a reflection of the mitral leaflet stresses imposed by the procedure. METHODS AND RESULTS: Eight sheep were studied immediately after surgical placement of (1) a force transducer interposed between sutures approximating the central leaflet edges and (2) radiopaque markers around the mitral annulus and leaflet edges. Computer-aided analysis of videofluorograms was used to obtained 3D marker coordinates. Simultaneous measurements of F(A), septal-lateral annular dimension (L(S-L)), leaflet edge separation (L(SEP)), anterior (L(AL)) and posterior (L(PL)) leaflet length, and hemodynamic variables were obtained at baseline (CTL) and during acute IMR (circumflex artery occlusion). F(A) was significantly elevated throughout the cardiac cycle during IMR compared with CTL, with maximum F(A) in diastole (0.26+/-0.05 versus 0.46+/-0.08 N, CTL versus IMR; P<0.05). Multivariable analysis revealed L(S-L) as the single independent predictor of maximum F(A) (P<0.001). Positive linear correlations were shown between values of F(A) and L(AL) and L(PL) (dependent variables). CONCLUSIONS: These experimental data demonstrate higher F(A) during IMR and cyclic changes in F(A) closely paralleling changes in L(S-L), eg, being greatest in diastole when the annulus is largest. Increased F(A) during IMR is probably indicative of successful therapeutic intent, but higher diastolic leaflet stresses resulting from persistent or progressive mitral annular dilatation may adversely affect repair durability. This indirectly implies that concomitant mitral ring annuloplasty should be added to the Alfieri repair.

Acute Disease↗

Visualization of flow patterns distal to aortic valve prostheses in humans using a fast approach for cine 3D velocity mapping.

The fluid dynamic performance of mechanical heart valves differs from normal valves and thus is considered related to late clinical complications in patients. Since flow patterns evolving around heart valves are complex in space and time, flow visualization based on time-resolved 3D velocity data might add important information regarding the performance of specific valve designs in vivo. However, previous cine 3D techniques for three-directional phase-contrast velocity mapping suffer from long scan duration and therefore might hamper assessment in patients. A hybrid 3D phase-contrast sequence combining segmented k-space acquisition with short EPI readout trains is presented with its validation in vitro. The technique was applied to study flow patterns downstream from a bileaflet aortic prosthesis in six patients. Navigator echoes were incorporated for respiratory motion compensation. Before flow visualization, spurious phase errors due to concomitant gradient fields and eddy currents were corrected. Flow visualization was based on particle paths and animated velocity vector plots. Dedicated algorithms for particle path integration were implemented to account for the considerable motion of the ascending aorta during the cardiac cycle. A distinct flow pattern reflecting the valve design was observed closest to the valve during early flow acceleration. Reverse flow occurred adjacent to high velocity jets and above the hinge housings. Later in systole, flow became confined to the central vessel area and reverse flow along the inner aortic curvature developed. Further downstream from the valve, flow patterns varied considerably among patients, indicating the impact of varying aortic anatomy in vivo. It is concluded that MR velocity mapping is a potential tool for studying 3D flow patterns evolving around heart valve prostheses in humans. J. Magn. Reson. Imaging 2001;13:690-698.

Aged↗

Influence of anterior mitral leaflet second-order chordae on leaflet dynamics and valve competence.

BACKGROUND: Chordal transposition is used in mitral valve repair, yet the effects of second-order chord transection on valve function have not been extensively studied. We evaluated leaflet coaptation, three-dimensional anterior mitral valve leaflet shape, and valve competence after cutting anterior second-order chordae. METHODS: In 8 sheep radiopaque markers were affixed to the left ventricle, mitral annulus, and leaflets. Animals were studied immediately with biplane videofluoroscopy and echocardiography before (Control) and after (Cut2) severing two anterior second-order "strut" chordae. Leaflet coaptation was assessed as separation between leaflet edge markers in the midleaflet and near each commissure (anterior commissure, posterior commissure). Anterior leaflet geometry was determined 100 milliseconds after end-diastole from three-dimensional coordinates of 13 markers. RESULTS: Anterior leaflet geometry changed only slightly after chordal transection without inducing mitral regurgitation. Leaflet coaptation times were 79+/-17 and 87+/-22 milliseconds at the anterior commissure; 72+/-21, 72+/-19 milliseconds at midleaflet, and 71+/-12 and 75+/-8 milliseconds at the posterior commissure (p = NS) for Control and Cut2, respectively. CONCLUSIONS: Cutting anterior second-order chordae did not cause delayed leaflet coaptation, alter leaflet shape, or create mitral regurgitation. These data indicate that transposition of second-order anterior chordae ("strut" chordae) is not deleterious to anterior leaflet motion per se.

Animals↗

Self-management of oral anticoagulation in children with congenital heart disease.

OBJECTIVE: The concept of self-management of oral anticoagulation has been shown to entail better quality of treatment than conventional management when assessed in selected adults. We have extended the concept of self-management to include children with congenital cardiac disease, hypothesizing self-management of oral anticoagulation is also possible in this subset of patients. Our aim was to assess the quality of self-management. METHODS: We trained 14 children aged from 2.2 to 15.6 years, with a mean age of 9.7 years, and their parents, in domiciliary analysis of the International Normalized Ratio and necessary adjustment of dosage of coumarin. The curriculum for training lasted for 27 weeks, and the patients and their parents were followed for a period of up to 31 months by weekly measurement of the values obtained for the International Normalized Ratio. RESULTS: The patients were observed over a mean of 547 days, with a range from 214 to 953 days. The patients were within the therapeutic targetted range of the International Normalized Ratio for a median of 65.5% of the time, with a range from 17.6% to 90.4%. None of the patients experienced thromboembolic or bleeding complications requiring doctoral intervention. All the patients and their parents expressed full satisfaction with the treatment. CONCLUSION: Self-management of oral anticoagulation provides a good quality of treatment, which is feasible and safe in selected children with congenital cardiac disease.

Administration, Oral↗

Self-management of oral anticoagulant therapy for mechanical heart valve patients.

OBJECTIVE: Self-management of oral anticoagulant therapy (OAT) has shown good results on a short-term basis. We hypothesize that self-management of OAT provides a better quality of treatment than conventional management also on a long-term basis. The aim of this study was to assess the quality of self-management of OAT in patients with mechanical heart valve prostheses on a 4-year perspective in a prospective, non-randomized study. DESIGN: Twenty-four patients with mechanical heart valves and on self-managed OAT were followed for up to 4 years. A matched, retrospectively selected group of conventionally managed heart valve patients (control group) was used as reference. RESULTS: The median observation time was 1175 days (range: 174-1428 days). The self-managed patients were within therapeutic INR target range for a mean of 78.0% (range: 36.1%-93.9%) of the time compared with 61.0% (range 37.4%-2.9%) for the control group. CONCLUSION: Self-management of OAT is a feasible and safe concept for selected patients with mechanical heart valve prostheses also on a long-term basis. It provides at least as good and most likely better quality of anticoagulant therapy than conventional management assessed by time within the therapeutic International Normalized Ratio (INR) target range.

Administration, Oral↗

Right heart assist ensures hemodynamic stability during beating heart coronary surgery on marginal arteries. An animal experimental porcine study.

OBJECTIVES: In many heart centers myocardial revascularization using beating heart coronary surgery has partly replaced conventional coronary artery bypass grafting (cCABG) using cardiopulmonary bypass. However, access to the marginal arteries is problematic and hampered by space limitations, which might compromise the quality of the anastomoses and it entails a significant risk of hemodynamic instability subsequent to the manipulations of the heart. Hemodynamic impairment may be caused by dislocation of the low-pressure right atrium and ventricle. Therefore, it was hypothesized that the use of Right Heart Assist (RHA) may be able to ensure hemodynamic stability when tilting and manipulating the heart. DESIGN: In an animal experimental model RHA was implemented in order to study the hemodynamic impact of dislocating the heart in a standardized fashion. RESULTS: Dislocation of the unassisted heart to expose the first and second marginal branches caused a decline in arterial blood pressure, cardiac output and venous saturation of 38-48%. Supported by RHA this decrease was minimized to 0-17%. CONCLUSION: RHA for beating heart procedures indicates several advantages: ample time and safety while making the anastomoses at the marginal branches, less space limitations and enhanced control of hemodynamic stability compared with no RHA. This operation technique is challenging current practice and indications, and may potentially replace cCABG for the majority of patients.

Animals↗

Heart motion-adapted MR velocity mapping of blood velocity distribution downstream of aortic valve prostheses: initial experience.

PURPOSE: To investigate blood flow velocities and shear rates at two distances downstream of an artificial aortic valve in patients. MATERIALS AND METHODS: Blood velocity was quantified downstream of the valve prosthesis (for replacement after aortic valve stenosis or combined stenosis and regurgitation) in 10 patients by using a magnetic resonance (MR) cine velocity mapping method in which the imaging section position is adapted according to the excursion of the valvular plane of the heart. Two acquisitions were performed to display the blood velocity distributions one-fourth valve diameter and one valve diameter downstream of the valve and to quantify blood volumes and shear rates. RESULTS: The velocity profiles measured during flow acceleration one-fourth valve diameter downstream were characterized by a distinct pattern of two lateral jets and one central jet of antegrade flow. High shear rates were found along the leaflet tips. The profiles obtained one valve diameter downstream were skewed, with varying velocity patterns among patients. Peak shear rates were found close to the vessel wall. With correction for through-plane motion of the valve, the mean apparent regurgitant fraction (+/- SD) was 14% +/- 6; the mean regurgitant fraction without correction was 9% +/- 5. CONCLUSION: The described noninvasive procedure for velocity mapping enables measurements close to the valve and thus evaluation of blood flow patterns with respect to valve design in humans.

Adult↗

[Turbulence and high intensity transient signals (HITS) as a parameter for optimum orientation of mechanical heart valves].

BACKGROUND: In previous studies, the impact of valve orientation on the hemodynamic performance of mechanical aortic valves has been demonstrated. This study investigates Turbulence (RNS values) and High Intensity Transient Signals (HITS) as a new and objective parameter for hemodynamics in various orientations of Medtronic Hall (MH) and St. Jude Medical (SJM) aortic valves. METHODS: Rotation devices carrying a MH or SJM valve were implanted into four pigs. The device allowed valve rotation without reopening the aorta. In various orientations, turbulent shear stresses (RNS values) and HITS were measured. RESULTS: RNS and HITS changed for both valve designs in the different orientations, with superior results for the MH in the hemodynamically best orientation. Downstream turbulence (RNS) and HITS varied in the same direction, but a one to one correlation was not observed. CONCLUSIONS: RNS and HITS vary with respect to valve orientation and design with superior results for the tilting disc valve. Both MH and SJM valves showed lower turbulence and HITS counts in their hemodynamically best orientations. HITS were related to downstream turbulence and the hemodynamic performance of the mechanical aortic valves.

Animals↗

Doppler flow measurement using surface integration of velocity vectors (SIVV): in vitro validation.

Blood flow measurement using an improved surface integration of velocity vectors (SIVV) technique was tested in in vitro phantoms. SIVV was compared with true flow (12-116 mL/s) in a steady-state model using two angles of insonation (45 degrees and 60 degrees ) and two vessel sizes (internal diameter = 11 and 19 mm). Repeatability of the method was tested at various flow rates for each angle of insonation and vessel. In a univentricular pulsatile model, SIVV flow measured at the mitral inlet was compared to true flow (29-61 mL/s). Correlation was excellent for the 19-mm vessel (r(2)= 0.99). There was a systematic bias but close limits of agreement (mean +/- 2 SD = -24.1% +/- 7.6% at 45 degrees; +16.4% +/- 11.0% at 60 degrees ). Using the 11-mm vessel, a quadratic relationship was demonstrated between between SIVV and true flow (r(2) = 0.98-0.99), regardless of the angle of insonation. In the pulsatile system, good agreement and correlation were shown (r(2) = 0.94, mean +/- 2 SD = -4.7 +/- 10.1%). The coefficients of variation for repeated SIVV measurements ranged from 0.9% to 10.3%. This method demonstrates precision and repeatability, and is potentially useful for clinical measurements.

Blood Flow Velocity↗

Downstream turbulence and high intensity transient signals (HITS) following aortic valve replacement with Medtronic Hall or St. Jude Medical valve substitutes.

OBJECTIVE: High intensity transient signals (HITS) representing microembolization to the brain have been found to contribute to cognitive impairment and psychoneurological dysfunction in patients carrying a mechanical aortic valve. It is unknown, whether HITS represent gaseous or solid emboli. This animal study evaluates the impact of valve orientation on HITS for two different mechanical valves with both valves implanted in their best and worst orientation, which has been defined in previous studies with respect to downstream turbulence. METHODS: In four pigs a rotation device carrying either a Medtronic Hall (MH) or St. Jude Medical (SJM) valve size 23 mm was implanted. The device allowed rotation of the implanted valves without reopening of the aorta. Approximately 30 min after weaning from extracorporeal circulation, a Doppler probe was placed on both common carotid arteries. In different orientations of the implanted valves (best and worst position), HITS were detected by the Doppler probe and recorded for ten min by a transcranial Doppler sonography device (Medilab Inc., Estenfeld, Germany). RESULTS: HITS showed significant change with rotation for both valve designs. With the major orifice of the MH oriented towards the non-coronary leaflet (optimum position) very low HITS-counts (0.8-1.7/min) were observed. In the worst orientation HITS rose to 43-66/min. For the SJM the HITS count in the optimum position was 23.4-24/min and in the worst orientation 38-48/min. CONCLUSIONS: Valve orientation has an important impact on microembolization to the brain. In the optimum orientation (large orifice facing the non-coronary leaflet) the Medtronic Hall valve showed negligible incidence of HITS. The St. Jude Medical bileaflet valve showed less variation but demonstrated significant HITS counts at any orientation. As the MH in the worst position shows significantly higher turbulent stresses than the SJM but no higher incidence of HITS, a strong correlation between turbulence and HITS was not demonstrated by this study.

Animals↗

High-intensity transient signals (HITS) as a parameter for optimum orientation of mechanical aortic valves.

BACKGROUND: In previous studies [1,2], the impact of valve orientation on the hemodynamic performance of mechanical aortic valves has been demonstrated. This study investigates Turbulence (RNS values) and High Intensity Transient Signals (HITS) as a new and objective parameter for hemodynamics in different orientations of Medtronic Hall (MH) and St. Jude Medical (SJM) aortic valves. METHODS: A rotation device carrying MH or SJM valves was implanted in 4 pigs. The device allowed valve rotation without reopening the aorta. In different orientations, turbulent shear stresses (RNS values) and HITS were measured. RESULTS: RNS and HITS changed for both valve designs in various orientations, with superior results for the MH in the hemodynamically best orientation. Downstream turbulence (RNS) and HITS varied into the same direction, but a one-to-one correlation was not observed. CONCLUSIONS: RNS and HITS vary with respect to valve orientation and design with superior results for the tilting disc valve. Both MH and SJM valves showed lower turbulence and HITS counts in their hemodynamically best orientations. HITS were related to downstream turbulence and the hemodynamic performance of the mechanical aortic valves.

Animals↗

Pediatric cardiac output measurement using surface integration of velocity vectors: an in vivo validation study.

OBJECTIVE: To test the accuracy and reproducibility of systemic cardiac output (CO) measurements using surface integration of velocity vectors (SIVV) in a pediatric animal model with hemodynamic instability and to compare SIVV with traditional pulsed-wave Doppler measurements. DESIGN: Prospective, comparative study. SETTING: Animal research laboratory at a university medical center. SUBJECTS: Eight piglets weighing 10-15 kg. INTERVENTIONS: Hemodynamic instability was induced by using inhalation of isoflurane and infusions of colloid and dobutamine. MEASUREMENTS: SIVV CO was measured at the left ventricular outflow tract, the aortic valve, and ascending aorta. Transit time CO was used as the reference standard. RESULTS: There was good agreement between SIVV and transit time CO. At high frame rates, the mean difference +/- 2 SD between the two methods was 0.01+/-0.27 L/min for measurements at the left ventricular outflow tract, 0.08+/-0.26 L/min for the ascending aorta, and 0.06+/-0.25 L/min for the aortic valve. At low frame rates, measurements were 0.06+/-0.25, 0.19+/-0.32, and 0.14+/-0.30 L/min for the left ventricular outflow tract, ascending aorta, and aortic valve, respectively. There were no differences between the three sites at high frame rates. Agreement between pulsed-wave Doppler and transit time CO was poorer, with a mean difference +/- 2 SD of 0.09+/-0.93 L/min. Repeated SIVV measurements taken at a period of relative hemodynamic stability differed by a mean difference +/-2 SD of 0.01+/-0.22 L/min, with a coefficient of variation = 7.6%. Intraobserver coefficients of variation were 5.7%, 4.9%, and 4.1% at the left ventricular outflow tract, ascending aorta, and aortic valve, respectively. Interobserver variability was also small, with a coefficient of variation = 8.5%. CONCLUSIONS: SIVV is an accurate and reproducible flow measurement technique. It is a considerable improvement over currently used methods and is applicable to pediatric critical care.

Animals↗

A new method for quantitative evaluation of perceived sounds from mechanical heart valve prostheses.

Closing clicks from mechanical heart valve prostheses are transmitted to the patient's inner ear mainly in two different ways: as acoustically transmitted sound waves, and as vibrations transmitted through bones and vessels. The purpose of this study was to develop a method for quantifying what patients perceive as sound from their mechanical heart valve prostheses via these two routes. In this study, 34 patients with implanted mechanical bileaflet aortic and mitral valves (St Jude Medical and On-X) were included. Measurements were performed in a specially designed sound insulated chamber equipped with microphones, accelerometers, preamplifiers and a loudspeaker. The closing sounds measured with an accelerometer on the patient's chest were delayed 400 ms, amplified and played back to the patient through the loudspeaker. The patient adjusted the feedback sound to the same level as the 'real-time' clicks he or she perceived directly from his or her valve. In this way the feedback sound energy includes both the air- and the bone-transmitted energies. Sound pressure levels (SPLs) were quantified both in dB(A) and in the loudness unit sone according to ISO 532B (the Zwicker method). The mean air-transmitted SPL measured close to the patient's ear was 23 +/- 4 dB(A). The mean air- and bone-transmitted sounds and vibrations were perceived by the patients as an SPL of 34 +/- 5 dB(A). There was no statistically significant difference in the perceived sound from the two investigated bileaflet valves, and no difference between aortic and mitral valves. The study showed that the presented feedback method is capable of quantifying the perceived sounds and vibrations from mechanical heart valves, if the patient's hearing is not too impaired. Patients with implanted mechanical heart valve prostheses seem to perceive the sound from their valve two to three times higher than nearby persons, because of the additional bone-transmitted vibrations.

Acoustics↗

Chordal force distribution determines systolic mitral leaflet configuration and severity of functional mitral regurgitation.

OBJECTIVES: The purpose of this study was to investigate the impact of the chordae tendineae force distribution on systolic mitral leaflet geometry and mitral valve competence in vitro. BACKGROUND: Functional mitral regurgitation is caused by changes in several elements of the valve apparatus. Interaction among these have to comply with the chordal force distribution defined by the chordal coapting forces (F(c)) created by the transmitral pressure difference, which close the leaflets and the chordal tethering forces (FT) pulling the leaflets apart. METHODS: Porcine mitral valves (n = 5) were mounted in a left ventricular model where leading edge chordal forces measured by dedicated miniature force transducers were controlled by changing left ventricular pressure and papillary muscle position. Chordae geometry and occlusional leaflet area (OLA) needed to cover the leaflet orifice for a given leaflet configuration were determined by two-dimensional echo and reconstructed three-dimensionally. Occlusional leaflet area was used as expression for incomplete leaflet coaptation. Regurgitant fraction (RF) was measured with an electromagnetic flowmeter. RESULTS: Mixed procedure statistics revealed a linear correlation between the sum of the chordal net forces, sigma[Fc - FT]S, and OLA with regression coefficient (minimum - maximum) beta = -115 to -65 [mm2/N]; p < 0.001 and RF (beta = -0.06 to -0.01 [%/N]; p < 0.001). Increasing FT by papillary muscle malalignment restricted leaflet mobility, resulting in a tented leaflet configuration due to an apical and posterior shift of the coaptation line. Anterior leaflet coapting forces increased due to mitral leaflet remodeling, which generated a nonuniform regurgitant orifice area. CONCLUSIONS: Altered chordal force distribution caused functional mitral regurgitation based on tented leaflet configuration as observed clinically.

Animals↗