Prosthetic heart valve evaluation by magnetic resonance imaging.

OBJECTIVE: To evaluate the potential of magnetic resonance imaging (MRI) for evaluation of velocity fields downstream of prosthetic aortic valves. Furthermore, to provide comparative data from bileaflet aortic valve prostheses in vitro and in patients. METHODS: A pulsatile flow loop was set up in a 7.0 Tesla MRI scanner to study fluid velocity data downstream of a 25 mm aortic bileaflet heart valve prosthesis. Three dimensional surface plots of velocity fields were displayed. In six NYHA class I patients blood velocity profiles were studied downstream of their St. Jude Medical aortic valves using a 1.5 Tesla MRI whole-body scanner. Blood velocity data were displayed as mentioned above. RESULTS: Fluid velocity profiles obtained from in vitro studies 0.25 valve diameter downstream of the valve exhibited significant details about the cross sectional distribution of fluid velocities. This distribution completely reflected the valve design. Blood velocity profiles in humans were considerably smoother and in some cases skewed with the highest velocities toward the anterior-right ascending aortic wall. CONCLUSION: Display and interpretation of fluid and blood velocity data obtained downstream of prosthetic valves is feasible both in vitro and in vivo using the MRI technique. An in vitro model with a straight tube and the test valve oriented orthogonally to the long axis of the test tube does not entail fluid velocity profiles which are compatible to those obtained from humans, probably due to the much more complex human geometry, and variable alignment of the valve with the ascending aorta. With the steadily improving quality of MRI scanners this technique has significant potential for comparative in vitro and in vivo hemodynamic evaluation of heart valves.

Adult↗

In vivo analysis of dynamic tensile stresses at arterial end-to-end anastomoses. Influence of suture-line and graft on anastomotic biomechanics.

OBJECTIVE: to determine the influence of an anastomotic suture line and a graft on dynamic tensile stresses of vascular end-to-end anastomoses in vivo. MATERIAL AND METHODS: the abdominal aorta of twelve 35-kg pigs was used as an experimental model. Simultaneous recordings of internal arterial diameter and pressure were performed on each pig at 3 successive stages: (1) The genuine artery (REF), (2) artery-artery (A-A) and (3) graft-artery (G-A) anastomosis at 1-mm increments in the immediate perianastomotic area. Thereby, RD (relative distension), CC (compliance coefficient), E(p)(dynamic pressure-strain elastic modulus) and hysteresis loop areas could be calculated for every measuring point. RESULTS: the graft was significantly stiffer than REF. A-A and G-A anastomoses were significantly less compliant than REF. Maximum E(p), minimum CC and hysteresis loop areas were found at the anastomotic line due to minimum anastomotic RD. Downstream of the G-A anastomosis, the RD, CC, E(p)and loop areas were significantly different from REF, but significantly different from A-A. CONCLUSION: an animal model for acute studies of mechanical properties of vascular end-to-end anastomoses was developed. The main determinant for anastomotic biomechanics was the suture-line itself.

Anastomosis, Surgical↗

Functional remodelling and left ventricular dysfunction after repeated ischaemic episodes. A chronic experimental porcine model.

This experimental study was set up to investigate left ventricular function and remodelling after repeated ischaemic episodes using magnetic resonance imaging (MRI). A significant reduction in mortality due to coronary heart disease (CHD) has been explained by both a decline in the incidence of acute myocardial infarction (AMI) and an improved post-AMI survival rate, suggesting a change in the natural history of CHD. Experimental intracoronary microembolization can induce different ischaemic patterns and the functional impact of repeated ischaemic episodes different from occlusion of central epicardial arteries can be studied. In this study repeated intracoronary microembolizations were performed in 20 domestic pigs. After 129 d, MRI was performed for assessment of left ventricular volume, mass and wall stress. Six pigs underwent serial MRI at baseline, immediately after embolization and at the end of the observation period. Microembolizations induced acute myocardial infarct expansion and increased left ventricular wall stress preceding chronic remodelling. End systolic and end diastolic volumes increased from 15.1 +/- 2.7 cm3 to 41.3 +/- 11.5 cm 3 (p < 0.002), and from 52.0 +/- 6.7 cm3 to 81.1 +/- 9.2 cm3 (p < 0.0007), respectively. End systolic wall stress increased from and 17.5 +/- 2.7 to 29.7 +/- 6.2 N/m2 (p < 0.001). Left ventricular filling pressures and cardiac index were unchanged. Histological examination revealed a diffuse pattern of perivascular fibrosis covering 12 +/- 3% of the left ventricular wall. This study demonstrates that repeated ischaemic episodes different from confined regional myocardial infarctions induce acute infarct expansion and chronic left ventricular remodelling in pigs. Serial assessment of absolute left ventricular volumes and mass is important during acute/chronic remodelling.

Animals↗

Development of velocity profiles and retrograde flow in the porcine abdominal aorta under different haemodynamic conditions.

Low and/or oscillating wall shear stresses are related to the development of atherosclerosis and this oscillation is influenced by changes in basic haemodynamics (exercise). The objective of this study was to provide in vivo data on the development of velocity profiles and oscillating blood velocities in the abdominal aorta under varying haemodynamic conditions. Six anaesthetized, 90-kg pigs were used in the study. Abdominal aortic velocity profiles across the anterior-posterior diameter were acquired at different axial positions using 10 MHz pulsed Doppler ultrasound. Measurements were obtained under normal conditions and during cardiac pacing up to 170 beats/min. Velocity profiles were obtained during heart rates ranging between 58 and 169 beats/min, and during flow rates ranging between 0.57 and 2.89 l/min. Main outcome measures included minimum velocities, frequency index, shape of velocity profiles (velocity distribution index), Reynolds' numbers, and Womersley's frequency parameter. Velocity profiles were blunted, with lowest velocities at the distal posterior vessel wall. Multiple regression analysis showed the development of velocity profiles to be inversely correlated with the pulsatility index, Womersley's frequency parameter and the mean Reynolds' number (r = 0.89, p < 0.0005). Minimum velocities were negatively correlated with the PI, Womersley's frequency parameter and positively with the mean Reynolds' number (r = 0.94, p < 10(-8)). Retrograde velocities (and hence oscillating wall shear stresses) were present at mean Reynolds' number < 1000. The oscillation of blood velocities at the wall in the porcine abdominal aorta was highly dependent on general haemodynamics (i.e. flow, heart rate and vessel diameter as expressed in the Reynolds' numbers and Womersley's frequency parameters). The velocity profiles in the abdominal aorta were found to be far from parabolic. These findings have important implications for the understanding and future modelling of the complex haemodynamics in the abdominal aorta and their relation to the development of atherosclerotic disease.

Animals↗

High-resolution assessment of velocity fields and shear stresses distal to prosthetic heart valves using high-field magnetic resonance imaging.

BACKGROUND AND AIM OF THE STUDY: Complications after replacement of diseased heart valves with mechanical prostheses have been shown to be related to the hemodynamics distal to the valve. For this reason, the velocity patterns have been disclosed in vitro with a variety of different techniques. This study introduces a magnetic resonance imaging (MRI) -based technique, which entails easy acquisition of fluid velocity field data with a high accuracy and spatial resolution. METHODS: A high-field magnetic resonance scanner equipped with short echo time phase-contrast velocity measurement software was applied in a detailed mapping of the axial velocity profile across the entire vessel area at two positions downstream of a bileaflet valve prosthesis inserted in a pulsatile flow system in vitro. The laminar shear forces were calculated from the fluid velocity field data. RESULTS: The velocity profiles very close to the valve reflected the bileaflet design as also shown in previous studies, but the extent and velocities of the jet emanating from the slit between the leaflets were clearly better visualized. However, one diameter downstream of the valve the central jet was completely dispersed and the hemodynamic complexity was significantly reduced. Recirculation and retrograde flow regions that might be relevant for understanding typical long-term complications after implantation were observed close to the valve. CONCLUSIONS: In one scan experiment the presented method provides information on flow characteristics that previously required application of different types of experiment. Thus, the method seems promising as a new technique for detailed and extensive mapping of the velocities and laminar shear stresses downstream of prosthetic heart valves in vitro.

Blood Flow Velocity↗

High-frequency pressure fluctuations measured in heart valve patients.

BACKGROUND AND AIM OF THE STUDY: Due to the risk of thromboembolic complications, mechanical heart valve patients require life-long anticoagulant therapy, in contrast to bioprosthetic valves. The reason for this is still not fully understood. In vitro studies have demonstrated the presence of cavitation bubbles in the vicinity of mechanical heart valves, but not of bioprosthetic valves. When cavitation bubbles collapse, they release a significant amount of energy, which may damage the formed elements of the blood. A correlation between the presence of cavitation bubbles and high-frequency pressure oscillations has been established in vitro. Thus, the aim of this study was to measure and quantify high-frequency pressure oscillations in patients with normal, bioprosthetic or mechanical aortic valves. METHODS: Measurements were performed in six patients with normal aortic valves after coronary bypass surgery, in five patients fitted with a Carpentier-Edwards pericardial bioprosthesis, and in nine patients fitted with a St. Jude Medical or CarboMedics aortic valve. High-frequency pressure fluctuations were measured intraoperatively using a hydrophone placed near the aortic annulus. The root mean square (RMS) value of the high-frequency pressure signals were calculated in the frequency range 35-150 kHz. RESULTS: High-frequency pressure fluctuations, with intensities above the noise floor, were registered only in the vicinity of mechanical heart valve prostheses, and not in the vicinity of normal or bioprosthetic valves. The mean value of RMS pressure fluctuations was 0.5 Pa for normal aortic valves, 0.8 Pa for bioprosthetic valves, and 67 Pa for mechanical valves. CONCLUSIONS: This study is the first to show the presence of high-frequency pressure fluctuations in patients with mechanical valves.

Aged↗

Papillary muscle misalignment causes multiple mitral regurgitant jets: an ambiguous mechanism for functional mitral regurgitation.

BACKGROUND AND AIMS OF THE STUDY: The study aim was to test the hypothesis that asymmetric alignment (misalignment) of the papillary muscles is sufficient to cause incomplete mitral leaflet coaptation and functional mitral regurgitation (MR). METHODS: Different spatial relationships between the papillary muscles and the mitral annulus were investigated in isolated porcine mitral valves in vitro to assess the impact on mitral valve competence. The systolic occlusional leaflet area (OLA) needed to cover the mitral orifice and the anterolateral (ACOM) and posteromedial (PCOM) commissural portion (OLA(ACOM), OLA(PCOM)) were assessed by 2D echocardiography to quantitate incomplete mitral leaflet coaptation. The regurgitant fraction (RF) and MR jet location were assessed by a flow meter and color Doppler ultrasound. RESULTS: Posterolateral dislocation of the posteromedial papillary muscle impaired mitral leaflet coaptation at the corresponding half-portion of the mitral orifice (OLA(PCOM): 351-397 mm2 versus 296 mm2 (normal); p < 0.001) and modified the contralateral part (OLA(ACOM): 354-387 mm2 versus 304 mm2 (normal); p <0.001). The mitral leaflet coaptation line moved in apical and posterior directions, creating a commissural MR orifice at the PCOM side. At the ACOM side, anterior leaflet prolapse and restricted posterior leaflet mobility created an additional commissural regurgitant jet (RF = 0.11-0.13). Symmetrical papillary muscle misalignment restricted mitral leaflet mobility on both sides of the orifice in a synergistic manner (OLA(PCOM): 416-459 mm2 and OLA(ACOM): 427-489 mm2; both p <0.001 versus normal). The central MR jet orifice, which extended towards both commissures, caused more significant MR (RF = 0.15-0.26). CONCLUSIONS: Papillary muscle misalignment caused mitral regurgitant jet ambiguity with an anterior MR jet location following posteromedial papillary muscle displacement. These findings may improve understanding of the relation between myocardial lesion and mitral regurgitant jet location and thereby facilitate rational strategies for valvular interventions.

Animals↗

Assessment of perceived mechanical heart valve sound level in patients.

BACKGROUND AND AIM OF THE STUDY: When mechanical heart valves close, they generate an impulse that is transmitted to the patient's inner ear by two routes: (i) As acoustically transmitted sound waves; and (ii) as vibrations transmitted through bones and vessels. The aim of this study was to quantitate what patients perceive as sound from their mechanical heart valve prostheses - including both air-transmitted sound waves and bone-transmitted vibrations. METHODS: Thirty-four patients with implanted mechanical bileaflet aortic and mitral valves (St. Jude Medical and On-X) were included in the study. Measurements were performed in a specially designed sound-insulated chamber equipped with microphones, accelerometers, preamplifiers and a loud-speaker. The closing sounds measured by an accelerometer on the patient's chest were delayed 400 ms, amplified and played back to the patient through the loudspeaker. The patient adjusted the feedback sound to the same level as the 'real-time' clicks they perceived directly from their valve. In this way the feedback sound energy includes both the air- and bone-transmitted energies. Sound pressure levels (SPL) were quantitated in both dB(A) and in loudness units (sones) according to ISO 532B (Zwicker method). RESULTS: The mean air-transmitted SPL measured close to the patient's ear was 23 +/- 4 dB(A). The total air-and bone-transmitted sounds and vibrations were perceived by the patients as a SPL of 34 +/- 5 dB(A). There was no statistically significant difference in perceived sound from the two bileaflet valves investigated, and no difference between aortic and mitral valves. CONCLUSIONS: The study showed that the presented feedback method is capable of quantitating the perceived sounds and vibrations from mechanical heart valves, if the patient's hearing is not too impaired. Patients with implanted mechanical heart valve prostheses seem to perceive the sound from their valve two to four times higher than nearby persons, because of the additional bone-transmitted vibrations.

Adaptation, Psychological↗

[Self management of peroral anticoagulant therapy in patients with artificial heart valves].

Twenty-one heart valve operated patients (age 19-70 years) were trained in self-managed oral anticoagulant therapy using a home coagulometer (CoaguChek). Twenty patients accomplished between eight and 29 (median 24) months of self management and were fully capable of self management after 30 weeks of training. No patients experienced major bleeds or thrombo-embolic events. A control group of 20 patients from our department was matched, retrospectively, to the study group. The self-managing patients were within the therapeutic INR range 78% of the study period compared to 54% for the control patients. All self-managing patients had their median INR-value within the therapeutic range, versus only 14 in the control group. Self-management of oral anticoagulant therapy seems feasible for selected patients.

Adult↗

The hemodynamic impact of diffuse myocardial ischemic lesions: an animal experimental model based on intracoronary microembolization.

In ischemic heart disease, left ventricular function is affected by a diffuse and segmental loss of myocardium. The decline in the incidence of myocardial infarction and improved early revascularization in acute transmural ischemia predict a change in the natural history of ischemic heart disease. It is now believed that, minor ischemic episodes, which are known to induce multifocal myocardial degeneration, will predominate in the near future. The objective of the present study was to develop a clinically relevant experimental model for investigation of the pathophysiological significance of diffuse ischemic myocardial lesions. Cardiac performance was gradually depressed by selective intracoronary microembolization in 13 pigs. Left ventricular function was quantitated by ejection fraction (EF), pulmonary pressure, cardiac output, and derivatives of left ventricular pressure. Left ventricular volume was estimated by epicardial echocardiography, using a new, unbiased stereological volume estimator. A chronic substudy was performed in order to characterize the histological changes and to evaluate the feasibility of establishing a chronic preparation of the model. Embolization induced acute left ventricular dysfunction; left ventricular pressure change decreased from 966+/-274 to 637+/-146 mmHg/s, and early diastolic relaxation from 1403+/-515 to 824+/-344 mmHg/s, respectively. Ejection fraction decreased by 45%+/-5% and cardiac output by 29%+/-11%. End-diastolic volume increased significantly, from 66.1+/-13.2 to 77.0+/-19.4 cm3, and end-systolic volume increased from 35.9+/-13.9 to 52.3+/-7.6 cm3. No change in heart rate or left ventricular filling pressure was observed. Diffuse ischemic myocardial injury was identified after a mean follow-up of 40 days. Intracoronary microembolization induces acute left ventricular dysfunction due to microinfarcts. Increased left ventricular end-diastolic volume is the initial compensatory response to the acute impairment of cardiac performance in nontransmural myocardial ischemia. This model is suitable for the evaluation of the hemodynamic changes secondary to acute and chronic diffuse loss of functional myocardium.

Animals↗

Diameter and cross-sectional area relationship of the human main pulmonary artery. Evaluated by epicardial echocardiography.

Correct assessment of vessel cross-sectional area (CSA) is essential for reliable cardiac output (CO) measurements by means of pulsed Doppler echocardiography. In 23 patients who underwent coronary artery bypass grafting (CABG) the main pulmonary artery CSA and diameter changes were assessed by epicardial two-dimensional echocardiography using a 7.5 MHz cm2 transducer. Our data indicate that the shape of the pulmonary artery changes over time. Time averaged CSA ranged from 3.51 to 8.29 cm2 (mean 5.04 cm2; SD 1.3 cm2) and the distensibility varied from 13% to 33% (mean 23%; SD 5%). The limits of agreement for the CSA calculated from the most suitable diameter (when assuming vessel circularity) and the corresponding traced CSA (reference value) during peak systole were -0.16 +/- 0.56 cm2 (mean +/- 2SD). In this idealized set-up (not clinically implementable) the maximal discrepancy between the calculated and traced CSA was 12% and 17% during peak systole and diastole, respectively. Therefore, a potential error in CO determination is incurred if CSA is assessed from a single diameter.

Adult↗

Animal experimental implantation of an atrial septal defect occluder system.

OBJECTIVE: To establish the implantation technique for the atrial septal defect occluder system (ASDOS) device in an experimental animal model and to determine long term mechanical stability of the device and its in vivo properties in terms of biocompatibility and tissue reaction. MATERIALS AND METHODS: An atrial septal defect was created and the device implanted in 17 pigs (mean weight 30 kg). The implantation technique was refined and modified because of initial technical and anatomical complications during nine acute pilot studies. The technique proved to be feasible in eight subsequent survival studies. Four pigs were electively killed three months after implantation (group 1). The remaining four pigs were killed six months after implantation (group 2). RESULTS: Necropsy showed all devices were embedded in soft tissue three months after implantation. Microscopic examination of atrial septal tissue showed an acute granulomatous inflammatory reaction in group 1 and fibrosis in group 2. The intensity of the inflammatory reaction around the device was clearly milder in group 2, indicating a decline in the inflammatory response with time. Clinical and biochemical investigations indicated acceptable biocompatibility of the device. CONCLUSION: The implantation technique for the ASDOS device in a chronic pig model has been established. Biocompatibility of the device was acceptable.

Animals↗

Latissimus dorsi cardiomyoplasty: a chronic experimental porcine model. Feasibility study of cardiomyoplasty in Danish Landrace pigs and Göttingen minipigs.

Cardiomyoplasty is an experimental treatment for end-stage heart failure. We hypothesized that the porcine latissimus dorsi muscle (LDM) in an experimental porcine model is a suitable surrogate for a clinically relevant evaluation of this concept. Fourteen Danish Landrace (DL) pigs and six Göttingen minipigs (GM) were studied. The LDM was evaluated immediately after surgical dissection and in various phases: phase 1 (n = 4)--outcome of a partial vascular isolation (vascular delay), 2 to 3 weeks prior to heart wrapping in DL pigs; phase 2 (n = 6)--long-term flap survival of nonstimulated LDM cardiomyoplasty in DL pigs; phase 3 (n = 6)--outcome of nonstimulated cardiomyoplasty in GM; phase 4--one DL pig had dynamic cardiomyoplasty performed and was subjected to low-intensity LDM stimulation for 8 months. Isolation of the LDM of DL pigs and GM as a pedicled graft had no acute deleterious impact on the global blood supply. In phase 1a, partial vascular isolation and in situ recovery of the LDM resulted in a muscle encapsulated in fibrotic tissue, which hampered a later heart wrap. In phase 1b, a less extensive dissection diminished fibrosis and allowed subsequent wrapping. In phase 2, after 6 weeks of nonstimulated LDM cardiomyoplasty, the LDM of DL pigs was viable, with excellent heart-muscle integration. In phase 3, the same procedure applied in GM yielded the same result as that in DL pigs, but with a higher success rate owing to the learning phase.

Animals↗

Practicability of patient self-testing of oral anticoagulant therapy by the international normalized ratio (INR) using a portable whole blood monitor. A pilot investigation.

The prophylactic efficacy of long-term oral anticoagulant treatment (OAT) has been demonstrated in a number of clinical conditions with increased tendency to thromboembolism, and the number of individuals subjected to OAT in the industrialised world has increased substantially in recent years. Since this therapy requires considerable resources from both the health care system and the patients, the feasibility of patients' self-monitoring and self-management of OAT has been investigated (1,2,3). The anticipated advantages of this approach include improved convenience and compliance for the patient, who may increase his apprehension for managing the treatment. In addition, self-testing allows for more frequent control compared to the conventional out-patient approach. Importantly, a prerequisite for conceiving a safe and operational concept for patient self-management (PSM) is the availability of a portable INR monitoring system with an accuracy, precision, reproducibility, and long-term reliability comparable to standard coagulometric equipment. The purpose of the present study was to evaluate the feasibility of a commercially available INR-monitor. CoaguChek, for patient self-testing, through a step-wise investigation of the performance characteristics of the equipment in the laboratory, in command of the patient, and during self-testing and self-adjustment of treatment at home. Laboratory INR values were used as reference.

Administration, Oral↗