PubMed Health⌕ Search

Biomedical subjects

J M Ziriax

Publications and source records attributed to J M Ziriax.

13 recordsLinked to original sources

Determining localized garment insulation values from manikin studies: computational method and results.

The localized thermal insulation value expresses a garment's thermal resistance over the region which is covered by the garment, rather than over the entire surface of a subject or manikin. The determination of localized garment insulation values is critical to the development of high-resolution models of sensible heat exchange. A method is presented for determining and validating localized garment insulation values, based on whole-body insulation values (clo units) and using computer-aided design and thermal analysis software. Localized insulation values are presented for a catalog consisting of 106 garments and verified using computer-generated models. The values presented are suitable for use on volume element-based or surface element-based models of heat transfer involving clothed subjects.

Body Temperature Regulation↗

Inter-species extrapolation of skin heating resulting from millimeter wave irradiation: modeling and experimental results.

This study reports measurements of the skin surface temperature elevations during localized irradiation (94 GHz) of three species: rat (irradiated on lower abdomen), rhesus monkey (posterior forelimb), and human (posterior forearm). Two exposure conditions were examined: prolonged, low power density microwaves (LPM) and short-term, high power density microwaves (HPM). Temperature histories were compared with calculations from a bio-heat transfer model. The mean peak surface temperature increase was approximately 7.0 degrees C for the short-term HPM exposures for all three species/locations, and 8.5 degrees C (monkey, human) to 10.5 degrees C (rat) for the longer-duration LPM exposures. The HPM temperature histories are in close agreement with a one-dimensional conduction heat transfer model with negligible blood flow. The LPM temperature histories were compared with calculations from the bio-heat model, evaluated for various (constant) blood flow rates. Results suggest a variable blood flow model, reflecting a dynamic thermoregulatory response, may be more suited to describing skin surface temperature response under long-duration MMW irradiation.

Abdomen↗

Empirical validation of SAR values predicted by FDTD modeling.

Rapid increase in the use of numerical techniques to predict current density or specific absorption rate (SAR) in sophisticated three dimensional anatomical computer models of man and animals has resulted in the need to understand how numerical solutions of the complex electrodynamics equations match with empirical measurements. This aspect is particularly important because different numerical codes and computer models are used in research settings as a guide in designing clinical devices, telecommunication systems, and safety standards. To ensure compliance with safety guidelines during equipment design, manufacturing and maintenance, realistic and accurate models could be used as a bridge between empirical data and actual exposure conditions. Before these tools are transitioned into the hands of health safety officers and system designers, their accuracy and limitations must be verified under a variety of exposure conditions using available analytical and empirical dosimetry techniques. In this paper, empirical validation of SAR values predicted by finite difference time domain (FDTD) numerical code on sphere and rat is presented. The results of this study show a good agreement between empirical and theoretical methods and, thus, offer a relatively high confidence in SAR predictions obtained from digital anatomical models based on the FDTD numerical code.

Animals↗

Predicted SAR in Sprague-Dawley rat as a function of permittivity values.

Specific absorption rate (SAR) value is dependent on permittivity value. However, variability in the published permittivity values for human and animal tissue and the development of sophisticated 3-dimensional digital anatomical models to predict SAR values has resulted in the need to understand how model parameters (permittivity value) affect the predicted whole body and localized SAR values. In this paper, we establish the partial derivative of whole body SARs and localized SAR values (defined as SAR for individual organs with respect to a change in the permittivity values of all tissue types, as well as for those tissues with the most variable permittivity values. Variations in the published permittivity values may substantially influence whole body and localized SAR values, but only under special conditions. Orientation of the exposed object to the incident electromagnetic wave is one of the most crucial factors. Published 2001 Wiley-Liss, Inc.

Animals↗

Parametric dependence of SAR on permittivity values in a man model.

The development and widespread use of advanced three-dimensional digital anatomical models to calculate specific absorption rate (SAR) values in biological material has resulted in the need to understand how model parameters (e.g., permittivity value) affect the predicted whole-body and localized SAR values. The application of the man dosimetry model requires that permittivity values (dielectric value and conductivity) be allocated to the various tissues at all the frequencies to which the model will be exposed. In the 3-mm-resolution man model, the permittivity values for all 39 tissue-types were altered simultaneously for each orientation and applied frequency. In addition, permittivity values for muscle, fat, skin, and bone marrow were manipulated independently. The finite-difference time-domain code was used to predict localized and whole-body normalized SAR values. The model was processed in the far-field conditions at the resonant frequency (70 MHz) and above (200, 400, 918, and 2060 MHz) for E orientation. In addition, other orientations (K, H) of the model to the incident fields were used where no substantial resonant frequency exists. Variability in permittivity values did not substantially influence whole-body SAR values, while localized SAR values for individual tissues were substantially affected by these changes. Changes in permittivity had greatest effect on localized SAR values when they were low compare to the whole-body SAR value or when errors involved tissues that represent a substantial proportion of the body mass (i.e., muscle). Furthermore, we establish the partial derivative of whole-body and localized SAR values with respect to the dielectric value and conductivity for muscle independently. It was shown that uncertainties in dielectric value or conductivity do not substantially influence normalized whole-body SAR. Detailed investigation on localized SAR ratios showed that conductivity presents a more substantial factor in absorption of energy in tissues than dielectric value for almost all applied exposure conditions.

Absorption↗

Neural and behavioral teratological evaluation of rats exposed to ultra-wideband electromagnetic fields.

Several investigators have reported teratologic effects of electromagnetic field exposure. The majority of these studies have been performed at levels of exposure that could produce substantial heating of the animals. New and unique sources of ultra-wideband (UWB) electromagnetic fields are currently being developed and tested that are capable of generating nonthermalizing, high-peak-power, microwave (MW) pulses with nanosecond (ns) pulse widths, picosecond (ps) rise times, and an UWB of frequencies. Our study was performed to determine if teratological changes occur in rat pups as a result of (i) daily UWB exposures during gestation days 3-18, or (ii) as a result of both prenatal and postnatal (10 days) exposures. Dams were exposed either to (i) UWB irradiation from a Kentech system that emitted a 55 kV/m-peak E field, 300 ps rise time, and a 1.8 ns pulse width, average whole-body specific absorption rate 45 mW/kg; (ii) sham irradiation; or (iii) a positive control, lead (Pb) acetate solution (2000 microg/ml) continuously available in the drinking water. Offspring were examined for ontogeny (litter size, sex-ratios, weights, coat appearance, tooth-eruption, eye-opening, air-righting, and ultrasonic stress vocalizations). Male pups were tested on various performance measures (locomotor, water-maze learning, and fertilization capabilities). The pups postnatally exposed were examined for hippocampal morphology and operant behavior. Behavioral, functional, and morphological effects of UWB exposure were unremarkable with these exceptions: (i) The UWB-exposed pups emitted significantly more stress vocalizations than the sham-exposed pups; (ii) the medial-to-lateral length of the hippocampus was significantly longer in the UWB-exposed pups than in the sham-exposed animals; (iii) male offspring exposed in utero to UWB mated significantly less frequently than sham-exposed males, but when they did mate there was no difference in fertilization and offspring numbers from the sham group. There does not appear to be a unifying physiological or behavioral relationship among the significant differences observed, and our findings could be due to the expected spurious results derived when a large number of statistical comparisons are made. Significant effects found between our positive-controls and other groups on numerous measures indicates that the techniques used were sensitive enough to detect teratological effects. Bioelectromagnetics 21:524-537, 2000. Published 2000 Wiley-Liss, Inc.

Animals↗

Variability in EMF permittivity values: implications for SAR calculations.

Digital anatomical models of man and animals are available for use in numerical calculations to predict electromagnetic field (EMF)-induced specific absorption rate (SAR) values. To use these models, permittivity values are assigned to the various tissues for the EMF frequencies of interest. There is, as yet, no consensus on what are the best permittivity data. This study analyzed the variability in published permittivity data and investigated the effects of permittivity values that are proportional on SAR calculations. Whole-sphere averaged and localized SAR values along the diameter of a 4-cm sphere are calculated for EMF exposures in the radio frequency range of 1 MHz to 1 GHz. When the dimensions of a sphere are small compared to the wavelength (i.e., wavelength inside the material is greater than ten times the dimensions of the object), the whole-sphere averaged SAR is inversely proportional to the permittivity of the material composing the sphere. However, the localized SAR values generally do not have the same relation and, as a matter of fact, vary greatly depending on the location within the sphere. These results indicate that care must be taken in choosing the permittivity values used in calculating SAR values and some estimate of the dependence of the calculated SAR values on variability in permittivity should be determined.

Animals↗

Effects of high peak power microwaves on the retina of the rhesus monkey.

We studied the retinal effects of 1.25 GHz high peak power microwaves in Rhesus monkeys. Preexposure fundus photographs, retinal angiograms, and electroretinograms (ERG) were obtained to screen for normal ocular structure and function and, after exposure, as endpoints of the study. Histopathology of the retina was an additional endpoint. Seventeen monkeys were randomly assigned to receive sham exposure or pulsed microwave exposures. Microwaves were delivered anteriorly to the face at 0, 4.3, 8.4, or 20.2 W/kg spatially and temporally averaged retinal specific absorption rates (R-SAR). The pulse characteristics were 1.04 MW ( approximately 1.30 MW/kg temporal peak R-SAR), 5.59 micros pulse length at 0, 0.59, 1. 18, and 2.79 Hz pulse repetition rates. Exposure was 4 h per day and 3 days per week for 3 weeks, for a total of nine exposures. The preexposure and postexposure fundus pictures and angiograms were all within normal limits. The response of cone photoreceptors to light flash was enhanced in monkeys exposed at 8.4 or 20.2 W/kg R-SAR, but not in monkeys exposed at 4.3 W/kg R-SAR. Scotopic (rod) response, maximum (combined cone and rod) response, and Naka-Rushton R(max) and log K of scotopic b-waves were all within normal range. Retinal histopathology revealed the presence of enhanced glycogen storage in photoreceptors among sham (2/5), 8.4 W/kg (3/3), and 20.2 W/kg (2/5) exposed monkeys, while enhanced glycogen storage was not observed in the 4.3 W/kg (0/4) exposed group. Supranormal cone photoreceptor b-wave was R-SAR dependent and may be an early indicator of mild injury. However no evidence of degenerative changes and ERG depression was seen. We concluded that retinal injury is very unlikely at 4 W/kg. Functional changes that occur at higher R-SAR are probably reversible since we saw no evidence of histopathologic correlation with ERG changes. Bioelectromagnetics 21:439-454, 2000. Published 2000 Wiley-Liss, Inc.

Absorption↗

Establishing orally self-administered cocaine as a reinforcer in rats using home-cage pre-exposure.

1. Rats were force-exposed to a cocaine + saccharin solution in their home cage water bottles for five days. They were then given 5 h home-cage access to both cocaine and cocaine-free solutions for 40 days. 2. The subjects consumed large doses of the cocaine solution despite the ad libitum availability of water. 3. The animals were then trained on a task consisting of operant bar pressing rewarded on an intermittent schedule with a liquid cocaine reinforcer. 4. All subjects performed the operant task and consumed doses of cocaine solution which are preferred over water in other paradigms. 5. Levels of responding were significantly reduced in three of four subjects when vehicle was substituted for liquid cocaine as the reward. 6. This demonstrates that orally self-administered cocaine can be used as a reinforcer in rats.

Administration, Oral↗

Comparison of error patterns produced by scopolamine and MK-801 on repeated acquisition and transition baselines.

An understanding of the differential role of cholinergic and glutaminergic systems may be limited by the failure to move the analysis of learning impairments beyond an assessment of changes in overall accuracy. This paper reports the results of two studies in which the effects in rats of scopolamine (0.5-3.0 mg/kg IP), a cholinergic antagonist, and MK-801 (0.05-0.3 mg/kg IP), an NMDA-receptor antagonist, were compared in two different repeated learning procedures and the nature of the underlying error patterns produced by each was evaluated. The first study examined drug effects upon a repeated sequence acquisition procedure and found that while both drugs decreased overall accuracy in a dose-dependent manner, the predominant error pattern varied significantly with drug; scopolamine primarily produced skipping errors within the sequence, whereas MK-801 more prominently increased perseveration on the first and second members of the sequence. In the second study, which used a repeated transition procedure, both drugs again significantly decreased overall accuracy in a dose-dependent manner, but no consistent differences in error patterning produced by the drugs were observed. Thus, while both cholinergic and NMDA systems play a role in learning, the behavioral processes underlying the changes in overall accuracy may differ, as indicated by the differential patterns of errors produced by scopolamine and MK-801 in the repeated acquisition baseline. Furthermore, the observed differences in the underlying behavioral processes of scopolamine and MK-801 in the repeated acquisition but not on the repeated transition procedure suggest that each of the two drugs may affect more than one of the variables controlling behavior, with the relative impact of drug-related changes in controlling variables depending upon the operative contingencies of the learning task.

Animals↗

Molecular maximizing characterizes choice on Vaughan's (1981) procedure.

Pigeons keypecked on a two-key procedure in which their choice ratios during one time period determined the reinforcement rates assigned to each key during the next period (Vaughan, 1981). During each of four phases, which differed in the reinforcement rates they provided for different choice ratios, the duration of these periods was four minutes, duplicating one condition from Vaughan's study. During the other four phases, these periods lasted six seconds. When these periods were long, the results were similar to Vaughan's and appeared compatible with melioration theory. But when these periods were short, the data were consistent with molecular maximizing (see Silberberg & Ziriax, 1982) and were incompatible with melioration, molar maximizing, and matching. In a simulation, stat birds following a molecular-maximizing algorithm responded on the short- and long-period conditions of this experiment. When the time periods lasted four minutes, the results were similar to Vaughan's and to the results of the four-minute conditions of this study; when the time periods lasted six seconds, the choice data were similar to the data from real subjects for the six-second conditions. Thus, a molecular-maximizing response rule generated choice data comparable to those from the short- and long-period conditions of this experiment. These data show that, among extant accounts, choice on the Vaughan procedure is most compatible with molecular maximizing.

Journal Article↗

Concurrent variable-interval variable-ratio schedules can provide only weak evidence for matching.

Herrnstein and Heyman (1979) showed that when pigeons' pecking is reinforced on concurrent variable-interval variable-ratio schedules, (1) their behavior ratios match the ratio of the schedules' reinforcer frequencies, and (2) there is more responding on the variable interval. Since maximizing the reinforcement rate would require responding more on the variable ratio, these results were presented as establishing the primacy of matching over maximizing. In the present report, different ratios of behavior were simulated on a computer to see how they would affect reinforcement rates on these concurrent schedules. Over a wide range of experimenter-specified choice ratios, matching obtained - a result suggesting that changes in choice allocation produced changes in reinforcer frequencies that correspond to the matching outcome. Matching also occurred at arbitrarily selected choice ratios when reinforcement rates were algebraically determined by each schedule's reinforcement-feedback function. Additionally, three birds were exposed to concurrent variable-interval variable-ratio schedules contingent on key pecking in which hopper durations were varied in some conditions to produce experimenter-specified choice ratios. Matching generally obtained between choice ratios and reinforcer-frequency ratios at these different choice ratios. By suggesting that reinforcer frequencies track choice on this procedure, instead of vice versa, this outcome questions whether matching-as-outcome was due to matching-as-process in the Herrnstein and Heyman study.

Journal Article↗