PubMed Health⌕ Search

Biomedical subjects

J Mertz

Publications and source records attributed to J Mertz.

12 recordsLinked to original sources

Electro-optic response of second-harmonic generation membrane potential sensors.

We quantify and ascertain the nature of the second-harmonic generation (SHG) response of amphiphilic push-pull chromophores to a transmembrane electric field. Our technique is based on the application of an alternating field across labeled giant unilamelar vesicles. For chromophore responses that are purely electro-optic, our technique provides an estimate of photoinduced charge shifts based on the observed dispersion of the field response, in accord with a two-level perturbation theory. These results are applicable to the optimization of membrane potential sensors for SHG microscopy.

Cell Physiological Phenomena↗

Transmission confocal laser scanning microscopy with a virtual pinhole based on nonlinear detection.

We present a transmission-mode confocal laser scanning microscope system based on the use of second-harmonic generation (SHG) for signal detection. Our method exploits the quadratic intensity dependence of SHG to preferentially reveal unscattered signal light and reject out-of-focus scattered background. The SHG crystal acts as a virtual pinhole that remains self-aligned without the need for descanning.

Microscopy, Confocal↗

Two-photon microscopy in brain tissue: parameters influencing the imaging depth.

Light scattering by tissue limits the imaging depth of two-photon microscopy and its use for functional brain imaging in vivo. We investigate the influence of scattering on both fluorescence excitation and collection, and identify tissue and instrument parameters that limit the imaging depth in the brain. (i) In brain slices, we measured that the scattering length at lambda=800 nm is a factor 2 higher in juvenile cortical tissue (P14-P18) than in adult tissue (P90). (ii) In a detection geometry typical for in vivo imaging, we show that the collected fraction of fluorescence drops at large depths, and that it is proportional to the square of the effective angular acceptance of the detection optics. Matching the angular acceptance of the microscope to that of the objective lens can result in a gain of approximately 3 in collection efficiency at large depths (>500 microm). A low-magnification (20x), high-numerical aperture objective (0.95) further increases fluorescence collection by a factor of approximately 10 compared with a standard 60x-63x objective without compromising the resolution. This improvement should allow fluorescence measurements related to neuronal or vascular brain activity at >100 microm deeper than with standard objectives.

Aging↗

Odor-evoked calcium signals in dendrites of rat mitral cells.

Mitral cell dendrites do more than passively integrate and convey synaptic potentials to the soma, they release transmitter onto local interneurones to mediate recurrent and lateral inhibition. Several mechanisms may control the level of dendritic intracellular calcium ([Ca(2+)]) and define timing for dendritic release. Here we investigated in vivo, how odor controls calcium dynamics in mitral cell dendrites by combining intracellular recording and two-photon microscopy imaging of [Ca(2+)]. During odor stimulation, two types of [Ca(2+)] changes accompany membrane potential oscillations that are phase-locked with the respiratory cycle: (i) one is graded and parallels the membrane potential, even below the threshold for action potential firing; (ii) a second is transient, triggered by sodium action potentials that invade the entire dendritic tree. These results indicate that mitral cell dendritic compartments are synchronized by action potentials and suggest that the efficacy of dendritic synapses is finely tuned by odor-evoked graded changes in [Ca(2+)].

Action Potentials↗

Coherent scattering in multi-harmonic light microscopy.

By focusing a pulsed laser beam into a sample, harmonic up-conversion can be generated as well as multi-photon excited fluorescence. Whereas multi-photon excited fluorescence microscopy is well established, the use of multi-harmonic generation for three-dimensional image contrast is very recent. Both techniques can provide similar resolution and, for adequate radiating source density, comparable signal levels, allowing them to be combined in a single versatile instrument. However, harmonic generation differs fundamentally from fluorescence generation in that it is coherent and produces radiation patterns that are highly sensitive to phase. As such, multi-harmonic generation microscopy provides a unique window into molecular spatial organization that is inaccessible to fluorescence.

Animals↗

[Physicians and the death penalty. Physicians' participation in the death penalty and executions].

Doctorss' participation in the death penalty and in executions is described from the literature on the subject. Expert testimonies from psychiatrists during death penalty trials, concerning the mental condition and the possibility of future violent behaviour of the person charged, are of decisive importance for whether the death penalty is imposed or not. By treating prisoners on death row for mental illness the doctor can precipitate the execution. Psychiatrists make fit-for-execution certificates stating whether the condemned is healthy enough to be executed. The doctor monitors the execution and gives advice to the executioner; at an intravenous execution the doctor and medical technique are further involved. It is concluded that doctors should not participate in the death penalty and executions, and that they should discuss ways of achieving such a situation.

Capital Punishment↗