Luminescent transition metal complexes as sensors: structural effects on pH response.

A series of luminescent transition metal complexes using the pH-sensitive ligand 5-carboxy-1,10-phenanthroline has been synthesized and characterized. The complexes, based on Ru(II) and Re(I), show monotonic changes in both luminescent intensity and lifetime with pH values over the range 2 < pH < 9. The impact of various structural features on both the range of pH sensitivity and dynamic response was studied using both intensity and lifetime measurements. It was possible to predictably tune the pH sensitivity range over about 1.5 pKa units. While significant variation in the dynamic response range was observed, the correlation with structural features needs further study.

Journal Article↗

Determining oxygen diffusion coefficients in polymer films by lifetimes of luminescent complexes measured in the frequency domain.

Polymer films doped with luminescent ruthenium complexes are proving to be important oxygen sensors. We describe a technique using lifetime measurements in the frequency domain for determining the diffusion coefficient of oxygen through various polymer supports. These fundamental measurements will allow for more rational design of improved sensors. Three types of polymers were doped with [Ru(4,7-diphenyl-1,10-phenanthroline)3]Cl2. We monitored the luminescence versus time after applying a step increase in the oxygen pressure at the surface of the film. We modeled the decrease in apparent lifetime as a function of time using the diffusion coefficient of oxygen in the polymer as the only adjustable parameter. The model accurately predicted the lifetime versus time curves, and diffusion coefficients agreed well with those obtained from intensity measurements. The advantages and disadvantages of the lifetime technique to those used earlier are discussed.

Diffusion↗

pH-dependent photophysical behavior of rhenium complexes containing hydroxypyridine ligands.

Data related to the pH-dependent photophysics of a class of rhenium complexes containing the hydroxypyridine ligand are presented. Data include ground-state pK(a) values, emission energies, and lifetimes. The complexes all have ground-state pK(a) values near 7.0 and exhibit a dramatic change in emission intensity near this pH. The lifetimes of these complexes, however, are constant over this pH range. A model is presented to account for the observed photophysical behavior. The pH-dependent emission properties of these species make them good candidates for luminescence-based pH probes, especially in the environmental and biomedical fields.

Hydrogen-Ion Concentration↗

Comparison of methods for rapid evaluation of lifetimes of exponential decays.

For evaluating exponential luminescence decays, there are a variety of computational rapid integral methods based on the areas of the decay under different binned intervals. Using both Monte Carlo methods and experimental photon counting data, we compare the standard rapid lifetime determination method (SRLD), optimized rapid lifetime determination methods (ORLD), maximum likelihood estimator method (MLE), and the phase plane method (PPM). The different techniques are compared with respect to precision, accuracy, sensitivity to binning range, and the effect of baseline interference. The MLE provides the best overall precision, but requires 10 bins and is sensitive to very small uncorrected baselines. The ORLD provides nearly as good precision using only two bins and is much more immune to uncompensated baselines. The PPM requires more bins than the MLE and has systematic errors, but is largely resistant to baseline issues. Therefore, depending on the data acquisition method and the number of bins that can be readily employed, the ORLD and MLE are the preferred methods for reasonable signal-to-noise ratios.

Algorithms↗

Photostability of luminescent ruthenium(II) complexes in polymers and in solution.

The effects of oxygen on the photochemical properties of ruthenium(II) complexes in solution and in polymers are reported. In solution, the complex is actually protected from decomposition by the presence of oxygen as a result of deactivation of the complex by oxygen quenching before it can undergo ligand loss by monomolecular dissociation; however, in polymers, the presence of oxygen increases photochemical decomposition. Singlet molecular oxygen, a product of the oxygen quenching process, may attack the ground state complex or triplet oxygen may directly attack the excited state of the complex. Both mechanisms may be involved in the photodestruction of the complex. The role of oxygen in the photodecomposition was examined by monitoring the photochemical decomposition of various complexes of different singlet oxygen reactivity, as well as absorption and mass spectroscopy studies. It is suggested that in polymers, unlike in solutions, the newly formed reactive singlet oxygen is not able to diffuse away from the complex. The singlet oxygen, trapped in close proximity to the metal complex, has an enhanced opportunity to attack it. This cage effect is supported by studies using tris(1,10-phenanthroline)ruthenium(II) in poly(ethylene glycol) of increasing molecular weight to create an increasingly constraining cage around the complex. Increased poly(ethylene glycol) molecular weight leads to increased oxygen attack of the complex, supporting the cage effect.

Journal Article↗

Conventional, confocal and two-photon fluorescence microscopy investigations of polymer-supported oxygen sensors.

Luminescence-based, polymer-supported oxygen sensors, particularly those based on platinum group complexes, continue to be of analytical importance. Commercial applications range from the macroscopic (e.g. aerodynamic investigations in wind tunnels, monitoring of oxygen concentration during fermentation, and measurement of biological oxygen demand) to the microscopic (e.g. imaging of oxygen in blood, tissue, cells and other biological samples). Problems hindering the design of improved oxygen sensors include non-linear Stern-Volmer calibration plots and the multi-exponentiality of measured lifetime decays, both of which are attributed primarily to heterogeneity of the sensor molecule in the polymer support matrix. Conventional, confocal and two-photon fluorescence microscopy have proven to be invaluable tools with which the microscale heterogeneity and response of luminescence-based oxygen sensors can be investigated and compared to the macroscopic response. Results obtained for three ruthenium(II) alpha-diimine complexes in polydimethylsiloxane polymer supports indicate the presence of unquenched microcrystals within the polymer matrix that probably degrade oxygen quenching sensitivity and linearity of the Stern-Volmer quenching plot. Two-photon fluorescence microscopy proved most useful for imaging microcrystals within sensor films, and conventional microscopy allowed direct comparison between microscopic and macroscopic sensor response. The implications of the results in the rational design and mass production of luminescence-based oxygen sensors are significant.

Journal Article↗

Self-referencing intensity measurements based on square-wave gated phase-modulation fluorimetry.

An adaptation of square-wave gated phase-modulation (GPM) fluorimetry allows for self-referenced intensity measurements without the complexity of dual excitation or dual emission wavelengths. This AC technique utilizes square-wave excitation, gated detection, a reference emitter, and a sensor molecule. The theory and experimental data demonstrating the effectiveness and advantages of the adapted GPM scheme are presented. One component must have an extremely short lifetime relative to the other. Both components are affected identically by changes in intensity of the excitation source, but the sensor intensity also depends on the concentration of the analyte. The fluctuations of the excitation source and any optical transmission changes are eliminated by ratioing the sensor emission to the reference emission. As the concentration of the analyte changes, the corresponding sensor intensity changes can be quantified through several schemes including digitization of the signal and digital integration or AC methods. To measure pH, digital methods are used with Na3[Tb(dpa)3] (dpa = 2,6-pyridinedicarboxylic acid) as the long-lived reference molecule and fluorescein as the short-lived sensor molecule. Measurements from the adapted GPM scheme are directly compared to conventional ratiometric measurements. Good agreement between the data collection methods is demonstrated through the apparent pKa. For the adapted GPM measurements, conventional measurements, and a global fit the apparent pKa values agree within less than 2%. A key element of the adapted GPM method is its insensitivity to fluctuations in the source intensity. For a roughly 8-fold change in the excitation intensity, the signal ratio changes by less than 3%.

Feedback↗

Elimination of fluorescence and scattering backgrounds in luminescence lifetime measurements using gated-phase fluorometry.

A new gated form of phase fluorometry for measuring lifetimes is presented. The technique uses a square-wave excitation and gates the detector on only during the off period of the excitation. Using a long-lived sample, this eliminates or reduces errors from scattered light and short-lived fluorescences. Using a square-wave modulated excitation source with a 50% duty cycle, traditional data treatment can be used after, at most, a simple pi/2 phase adjustment. A combination of theory and experimental results demonstrates the validity of this new gated method and its utility for eliminating or reducing background. The results are precise, accurate, eliminate scattering errors, and greatly reduce errors due to short-lived fluorescence impurities. Errors from fluorescence bleed-through into the detection period or a slow excitation source turn off can be mitigated by using an offset time prior to gating the detector on.

Journal Article↗

Multicomponent lifetime-based pH sensors utilizing constant-lifetime probes.

A multicomponent luminescent sensor system is described that uses probe species with constant lifetimes to generate an analyte-dependent change in the apparent sensor lifetime. This new sensing scheme not only allows for lifetime-based measurement techniques to be applied to sensors that employ static quenching interactions but also provides the ability to vary the sensitivity of the sensor system with simple changes in instrumental parameters. A model for the multicomponent sensor is presented, followed by data measured using a prototype pH sensor based on the model.

Biosensing Techniques↗

Method for measuring oxygen diffusion coefficients of polymer films by luminescence quenching.

To ascertain the relationship between the physical properties of polymer supports and the observed response of luminescence-based oxygen sensors, a quenching-based method was developed to measure oxygen diffusion in polymers. The method offers advantages over existing quenching-based techniques since it allows a simple correction for films of high optical density, and the computations do not assume uniform oxygen concentration throughout the film. Diffusion coefficients (D) were measured for a series of sensors with [Ru(Ph2phen)3]Cl2 (Ph2phen = 4,7-diphenyl-1,10-phenanthroline) asthe luminophore and polystyrene, poly(trimethylsilylmethyl methacrylate), poly(butyl methacrylate), poly(trimethylsilylmethyl methacrylate-co-butyl methacrylate), or poly(trimethylsilylmethyl methacrylate-co-1H, 1H-heptafluorobutyl methacrylate) as the support. The solvent from which the films were cast was varied, and filler materials such as hydrophobic, amorphous silica or tributyl phosphate plasticizer were added. Results are interpreted by a domain model in which the local environment of the sensor, rather than the bulk properties of the polymer, is the most critical parameter in sensor design.

Journal Article↗

Optimized gating scheme for rapid lifetime determinations of single-exponential luminescence lifetimes.

The rapid lifetime method (RLD) for determining excited-state lifetimes uses the ratio of the areas under two regions of the decay. To get good precision with the standard method, prior knowledge of the lifetime is essential to selecting the integration regions. As will be shown, the usual method of selecting integration regions is far from optimal. An optimal gating scheme that is more precise and much more forgiving in the selection of integration region than any of the prior methods will be shown. Monte Carlo simulations were performed to determine the optimal gating. Experimental data was used to confirm the capabilities of the optimized RLD. The speed of the optimal RLD is similar to the standard RLD but without the necessity of matching the integration interval to the lifetime for precise results.

Journal Article↗

Oxygen sensors based on luminescence quenching: interactions of pyrene with the polymer supports.

Oxygen quenching of pyrene has been studied in a diverse series of polymers. Most measurements were made using homo- or copolymers containing a poly(dimethylsiloxane) region. Systematic variations in the polymer properties have been made in order to delineate the structural features important for satisfactory use as supports for oxygen sensors. In particular, quenching behavior was examined as a function of the type and amount of copolymer cross-linkers; these were added to produce domains of different polarity and rigidity that would segregate the sensor molecule. A domain model (Xu, W.; et al. Anal. Chem. 1994, 66, 4133-4141) was used to explain the variations in oxygen-quenching properties as a function of additives and cross-linkers. The relative affinity of the different domains for the pyrene and the efficacy of the domains for oxygen quenching controls the overall behavior of the sensing response.

Electrodes↗

Oxygen sensors based on luminescence quenching: interactions of metal complexes with the polymer supports.

Oxygen quenching of [Ru(Ph2phen)3]Cl2 (Ph2phen = 4,7-diphenyl-1,10-phenanthroline) has been studied in a diverse series of polymers, most with a common poly-(dimethylsiloxane) (PDMS) component. Systematic variations in the polymer properties have been made in order to delineate the structural features important for satisfactory use of supports for oxygen sensors. Most measurements were made using homo- or copolymers containing a PDMS region, although some measurements were made on small ring siloxane polymers. In particular, quenching behavior was examined as a function of polymer structure as well as the type of and amount of polar copolymer cross-linkers. Cross-linkers were added to enhance the solubility of oxygen probes in an otherwise nonpolar polymer. In addition, hydrophobic silica was added to alter quenching properties. Domain models are used to explain the variations in oxygen quenching properties as a function of additives and cross-linkers. These considerations have led to the most sensitive ruthenium-based sensor reported to date. The relative affinity of the different domains for the complex and the efficacy of the domains for oxygen quenching control the overall behavior of the sensing response. Guidelines for design of suitable polymer supports for oxygen sensors are proposed.

Acrylates↗

An inexpensive microcomputer-based stopped-flow data acquisition system.

A low-cost (less than $2,500) microcomputer-controlled data acquisition system for use with a stopped-flow instrument is described. Data acquisition, reduction, signal averaging, kinetic modeling, and plotting are performed under software control. Applications to biological and inorganic systems are presented.

Computers↗