PubMed Health⌕ Search

Biomedical subjects

J P Couëtil

Publications and source records attributed to J P Couëtil.

3 recordsLinked to original sources

Single breath exhaled nitric oxide in lung transplant patients: a preliminary clinical study.

Exhaled nitric oxide is considered as a marker of airway inflammation. We report here our preliminary experience with single-breath exhaled nitric oxide measured in lung transplant patients with and without bronchiolitis obliterans syndrome and in cardiac transplant patients. Peak and end-expiratory nitric oxide concentrations did not differ between groups, but single-breath exhaled nitric oxide recordings were strikingly different in patients suffering from bronchiolitis obliterans syndrome, with a slower decrease from peak to end-expiratory nitric oxide concentration. Further studies are required in order to determine whether theses abnormalities reflect the inflammatory process of bronchiolitis obliterans syndrome.

Adult↗

Less invasive techniques for mitral valve surgery.

OBJECTIVE: Minimally invasive surgical techniques aim at reducing the consequences of currently used large incisions, such as bleeding, pain, and risk of infection. Although this new approach developed rapidly in coronary surgery, it remains questionable in mitral valve surgery. This article reports the longest experience with minimally invasive mitral valve surgery, with particular attention to approach and techniques. METHODS: From February 1996, the date of the first case of minimally invasive mitral valve reconstruction, to April 1997, 22 patients with a mean age of 54 +/- 2.7 years were subjected to mitral valve surgery performed with less invasive techniques. Exposure of the mitral valve was achieved through a minithoracotomy (n = 12) or a ministernotomy (n = 10). Video assistance was used in all cases. Peripheral arterial cannulation (n = 21) and venous drainage (n = 22) were used in most cases. RESULTS: In this series, valve surgery consisted in 19 repairs, two replacements, and one closure of a periprosthetic leak. In two cases it was necessary to convert to a larger incision. The average duration of cardiopulmonary bypass was 157 +/- 8.2 minutes, ventilatory assistance 16 +/- 4.6 hours, and intensive care unit stay 2.1 +/- 0.4 days. Two patients required reoperation for bleeding and another for early recurrence of mitral valve regurgitation. There were no deaths and all patients were discharged with normal valve function. At most recent follow-up, all patients were in functional class I, with resumption of normal activity. CONCLUSION: Mitral valve surgery can be performed safely by means of less invasive techniques, but with increased technical difficulty. A low asymmetric median sternotomy seems preferable to an anterior thoracotomy.

Cardiopulmonary Bypass↗

Carpentier-Edwards pericardial bioprosthesis in aortic position: long-term follow-up 1980 to 1994.

Aortic valve replacement with Carpentier-Edwards pericardial bioprosthesis was associated with excellent midterm clinical results. Long-term evaluation, however, remained to be determined. We reviewed the first 124 patients who underwent aortic valve replacement with a Carpentier-Edwards bioprosthesis at the Hôpital Broussais between 1980 and 1985. There were 67 males (54%) and 57 females (46%). The mean age at operation was 65 years (range, 18-83 years). The operative mortality (30 days) was 4%. All but 2 patients were followed up for an average of 7.7 years and a total of 973 patient years. There were 45 late deaths (4.7%/patient-year) of which 16 were valve-related (1.7%/patient-year). The actuarial survival rate was 49.9% at 12 years. The actuarial rate for freedom from valve-related mortality was 78.3% at 12 years. There were 7 thromboembolic events in 5 patients and 3 anticoagulation-related hemorrhages. Freedom from structural valve deterioration was 100% at 12 years and 83.3% at 13 years. We conclude that implantation of Carpentier-Edwards pericardial bioprosthesis in aortic position is associated with an excellent long-term clinical outcome. It is believed that the improved results of this valve result from the following original features: fully flexible stent, distensible struts, infrastent tissue mounting, optimal tissue orientation, and improved preservation.

Actuarial Analysis↗