PubMed Health⌕ Search

PubMed · 9576209

Less invasive techniques for mitral valve surgery.

Abstract

OBJECTIVE: Minimally invasive surgical techniques aim at reducing the consequences of currently used large incisions, such as bleeding, pain, and risk of infection. Although this new approach developed rapidly in coronary surgery, it remains questionable in mitral valve surgery. This article reports the longest experience with minimally invasive mitral valve surgery, with particular attention to approach and techniques. METHODS: From February 1996, the date of the first case of minimally invasive mitral valve reconstruction, to April 1997, 22 patients with a mean age of 54 +/- 2.7 years were subjected to mitral valve surgery performed with less invasive techniques. Exposure of the mitral valve was achieved through a minithoracotomy (n = 12) or a ministernotomy (n = 10). Video assistance was used in all cases. Peripheral arterial cannulation (n = 21) and venous drainage (n = 22) were used in most cases. RESULTS: In this series, valve surgery consisted in 19 repairs, two replacements, and one closure of a periprosthetic leak. In two cases it was necessary to convert to a larger incision. The average duration of cardiopulmonary bypass was 157 +/- 8.2 minutes, ventilatory assistance 16 +/- 4.6 hours, and intensive care unit stay 2.1 +/- 0.4 days. Two patients required reoperation for bleeding and another for early recurrence of mitral valve regurgitation. There were no deaths and all patients were discharged with normal valve function. At most recent follow-up, all patients were in functional class I, with resumption of normal activity. CONCLUSION: Mitral valve surgery can be performed safely by means of less invasive techniques, but with increased technical difficulty. A low asymmetric median sternotomy seems preferable to an anterior thoracotomy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D F Loulmet, A Carpentier, P W Cho, A Berrebi, N d'Attellis, C B Austin, J P Couëtil, P Lajos. 1998. Less invasive techniques for mitral valve surgery.. https://doi.org/10.1016/s0022-5223(98)70354-x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Invited commentary.

Explore the source record for details and available documents.

Cardiopulmonary Bypass↗

Continuous SvO2 measurement in infants undergoing congenital heart surgery--first clinical experiences with a new fiberoptic probe.

BACKGROUND: SvO2-guided therapy, using fiberoptic oximetric catheters can help to improve the outcome after complex congenital heart surgery especially in infants undergoing the Stage 1-Norwood-Procedure. So far, fiberoptic catheters have to be placed transthoracically by the surgeon into the vena cava or the pulmonary artery putting the infant at an additional risk of bleeding at the time of catheter removal. METHODS: We used a new percutaneously applicable fiberoptic probe for continuous monitoring of central venous saturation in three infants undergoing modifications of the Stage 1-Norwood-Procedure (reconstruction of the aortic arch), two in combination with a bidirectional cavopulmonary connection (Glenn shunt), the third with reconstruction of the pulmonary arteries (biventricular repair). The approved clinical monitoring system consisted of a small (2 F) fiberoptic probe and a bed-side-monitor. The probe was inserted via the routine central venous access for such a case. RESULTS: Continuous SvO2 measurement is feasible in infants using the CeVOX system in combination with routine central venous access, and the advantages of continuous monitoring are discussed. CONCLUSIONS: We believe that compared with transthoracically inserted oximetric catheter, the presented percutaneous technique avoids additional risks at the time of catheter removal (i.e. bleeding) and has become part of our standard management.

Cardiopulmonary Bypass↗

An alternative pathway for fibrinolysis is activated in patients who have undergone cardiopulmonary bypass surgery and major abdominal surgery.

INTRODUCTION: We conducted this prospective study in order to investigate the hypotheses that an alternative pathway for fibrinolysis is activated in patients who have undergone cardiopulmonary bypass (CPB) surgery and major abdominal surgery and that the levels of fibrin degradation products digested by polymorphonuclear neutrophil elastase (elastase-XDP) and the D-dimer increase in the patients' plasma. MATERIALS AND METHODS: We studied a total of 77 patients who were scheduled to undergo either CPB surgery (36 patients) or major abdominal surgery (41 patients) and then measured the elastase-XDP and D-dimer levels at several time points both during and after the surgeries. The CPB surgery was divided into surgery for aortic dissection (AD) and cardiac surgery. The major abdominal surgery consists of hepatic resection and esophagectomy. RESULTS: The elastase-XDP and D-dimer levels significantly increased in the patients who underwent both CPB surgery and major abdominal surgery. The elastase-XDP levels in AD surgery showed highest values at the end of the CPB, while the levels in the other surgeries reached their peak on the day after the surgery. Statistical difference was seen in the levels of elastase-XDP among the three subgroups undergoing a hepatic resection. While we found significant correlations between the levels of elastase-XDP and D-dimer in patients undergoing CPB surgery and a subsegmentectomy of a cirrhotic liver, the correlation coefficients were markedly low in comparison to those of the other surgeries. CONCLUSIONS: Our findings demonstrated that the elastase-mediated pathway of fibrinolysis is activated to varying degrees depending on the surgery performed. Variations in the correlation coefficients between the levels of elastase-XDP and D-dimer may suggest that elastase-mediated fibrinolysis play a different role from the physiological fibrinolysis mediated by plasmin.

Cardiopulmonary Bypass↗