PubMed Health⌕ Search

Biomedical subjects

J Pawliszyn

Publications and source records attributed to J Pawliszyn.

At least 19 recordsLinked to original sources

Preparation and applications of polypyrrole films in solid-phase microextraction.

Polypyrrole (PPY) and poly-N-phenylpyrrole (PPPY) films were prepared and applied for solid-phase microextraction (SPME). The extraction properties of the new films to volatile organic compounds were examined using an SPME device coupled with GC-flame ionization detection. A PPY-coated capillary was applied for in-tube SPME to evaluate its extraction efficiency towards less volatile compounds and ionic species. The porous surface structures of the films, revealed by scanning electron microscopy, provided high surface areas and allowed for high extraction efficiency. Compared with commercial SPME stationary phases, the new phases showed better selectivity and sensitivity toward polar, aromatic, basic and anionic compounds, due to their inherent multifunctional properties. In addition, PPY and PPPY films showed different selectivity to various groups of compounds studied, indicating that the selectivity of the films could be modified by introducing a new functional group (phenyl in PPPY) into the polymer. For in-tube SPME, the PPY-coated capillary showed superior extraction efficiency to commercial capillaries for a variety of compounds, demonstrating its potential applications for a wide range of analytes when coupled with HPLC. The sensitivity and selectivity of the films for SPME could be tuned by changing the film thickness. These results are in line with both the theoretical expectations and the results obtained by other methods, which indicate not only that PPY films can be used as new stationary phases for SPME. but also that SPME method may provide an alternative tool for studying materials like polypyrrole.

Capillary Action↗

Design and validation of portable SPME devices for rapid field air sampling and diffusion-based calibration.

The use of SPME fibers coated with porous polymer solid phases for quantitative purposes is limited due to effects such as interanalyte displacement and competitive adsorption. For air analysis, these problems can be averted by employing short exposure times to air samples flowing around the fiber. In these conditions, a simple mathematical model allows quantification without the need of calibration curves. This work describes two portable dynamic air sampling (PDAS) devices designed for application of this approach to nonequilibrium SPME sampling and determination of airborne volatile organic compounds (VOCs). The use of a PDAS device resulted in greater adsorbed VOC mass compared to the conventional SPME extraction in static air for qualitative screening of live plant aromas and contaminants in indoor air. For all studied air samples, an increase in the number of detected compounds and sensitivity was also observed. Quantification of aromatic VOCs in indoor air was also carried out using this approach and the PDAS/SPME device. Measured VOC concentrations were in low parts-per-billion by volume range using only 30-s SPME fiber exposure and were comparable to those obtained with a standard NIOSH method 1501. The use of PDAS/SPME devices reduced the total air sampling and analysis time by several orders of magnitude compared to the NIOSH 1501 method.

Journal Article↗

Sampling and analysis of airborne particulate matter and aerosols using in-needle trap and SPME fiber devices.

A needle trap device (NTD) and commercial poly(dimethylsiloxane) (PDMS) 7-microm film thickness solid-phase microextraction (SPME) fibers were used for the sampling and analysis of aerosols and airborne particulate matter (PM) from an inhaler-administered drug, spray insect repellant, and tailpipe diesel exhaust. The NTD consisted of a 0.53-mm o.d. stainless steel needle having 5 mm of quartz wool packing section near the needle tip. Samples were collected by drawing air across the NTD with a Luertip syringe or via direct exposure of the SPME fiber. The mass loading of PM was varied by adjusting the volume of air pulled through the NTD or by varying the sampling time for the SPME fiber. The air volumes ranged from 0.1 to 50 mL, and sampling times varied from 10 s to 16 min. Particulates were either trapped on the needle packing or sorbed onto the SPME fiber. The devices were introduced to a chromatograph/mass spectrometer (GC/MS) injector for 5 min desorption. In the case of the NTD, 10 microL of clean air was delivered by a gas-tight syringe to aid the introduction of desorbed analytes. The compounds sorbed onto particles extracted by the SPME fiber or trapped in the needle device were desorbed in the injector and no carry-over was observed. Both devices performed well in extracting airborne polycyclic aromatic hydrocarbons (PAHs) in diesel exhaust, triamcinolone acetonide in a dose of asthma drug and DEET in a dose of insect repellant spray. Results suggest that the NTDs and PDMS 7-microm fibers can be used for airborne particulate sampling and analysis, providing a simple, fast, reusable, and cost-effective screening tool. The advantage of the SPME fiber is the open-bed geometry allowing spectroscopic investigations of particulates; for example, with Raman microspectroscopy.

Journal Article↗

Polypyrrole-coated capillary coupled to HPLC for in-tube solid-phase microextraction and analysis of aromatic compounds in aqueous samples.

In-tube solid-phase microextraction (SPME) based on a polypyrrole (PPY)-coated capillary was investigated for the extraction of aromatic compounds from aqueous solutions. The PPY-coated capillary was coupled on-line to HPLC that was programmed with an autosampler to achieve automated in-tube SPME and HPLC analysis. Three groups of aromatics, including both polar and nonpolar compounds, were examined. The results demonstrated that the PPY coating had a higher extraction efficiency than the currently used commercial capillary coatings, especially for polycyclic aromatic compounds and polar aromatics due to the increasing pi-pi interactions, interactions by polar functional groups, and hydrophobic interactions between the polymer and the analytes. In addition to the functional groups in the PPY coating, which contributed to the higher extraction efficiency and selectivity toward analytes, the coating's porous surface structure,which was revealed by electron microscopy experiments, provided a high surface area that allowed for high extraction efficiency. It was found that the extraction efficiency and selectivity could be tuned by changing the coating thickness. The preliminary study of the extraction mechanism indicated that analytes were extracted onto the PPY coating mainly by an adsorption mechanism. The method was used for the extraction and analysis of both polar and nonpolar aromatics in aqueous samples.

Journal Article↗

Diffusion-based calibration for SPME analysis of aqueous samples.

When an SPME fiber is exposed for a short period of time to a flowing fluid sample, the amount of extracted analyte depends on its diffusion coefficient in the matrix medium, and it can be correlated to its concentration using a simple mathematical model. This work discusses the extension of this approach, already validated for gaseous samples and SPME fibers coated with strong adsorbent coatings, to the diffusion-based quantification of analytes present in aqueous samples. Dilute aqueous solutions of aromatic hydrocarbons were used as model samples and vials were modified to use conventional magnetic agitation with controlled tangential flow of the test solution around the fiber. It was demonstrated that, with proper selection of the stirring speed and sampling time, the same diffusion-based quantitative model used for gas samples could be employed. Under optimal conditions, the concentrations of the evaluated aromatic hydrocarbons were estimated with relative standard deviations between 0.8 and 3.6% and without deviation from the expected values within this precision range. Considering the extraction times involved, between 30 and 60 s, the approach here presented is the fastest possible technique for direct extraction of analytes from liquid samples.

Journal Article↗

Air sampling and analysis of volatile organic compounds with solid phase microextraction.

Solid phase microextraction (SPME) presents many advantages over conventional analytical methods by combining sampling, preconcentration, and direct transfer of the analytes into a standard gas chromatograph (GC). Since its commercial introduction in the early 1990s, SPME has been successfully applied to the sampling and analysis of environmental samples. This paper presents an overview of the current methods for air sampling and analysis with SPME using both grab and time-weighted average (TWA) modes. Methods include total volatile organic compounds (TVOCs), formaldehyde, and several target volatile organic compounds (VOCs). Field sampling data obtained with these methods in indoor air were validated with conventional methods based on sorbent tubes. The advantages and challenges associated with SPME for air sampling are also discussed. SPME is accurate, fast, sensitive, versatile, and cost-efficient, and could serve as a powerful alternative to conventional methods used by the research, industrial, regulatory, and academic communities.

Air Pollutants↗

Microextraction of drugs.

This review will attempt to provide an overview as well as a theoretical and practical understanding of the use of microextraction technologies for drug analysis. The majority of the published reports to date focus on the use of fibre solid-phase microextraction and so the review is significantly focused on this technology. Other areas of microextraction such as single drop and solvent film microextraction are also described. Where there are insufficient examples in the literature to illustrate important concepts, examples of non-drug analyses are presented. The review is intended for readers new to the field of microextraction or its use in drug extraction, but also provides an overview of the most recent advances in the field which may be of interest to more experienced users. Particular emphasis is placed on the effect various sample matrices have on extraction characteristics.

Adsorption↗

Dynamics of capillary isoelectric focusing in the absence of fluid flow: high-resolution computer simulation and experimental validation with whole column optical imaging.

A 150-component, dynamic electrophoresis simulator was developed and applied to the description of capillary isoelectric focusing (CIEF) of amphoteric substances in quiescent solution. The simulator is shown to be capable of producing high-resolution pH 3-10 focusing data with 140 individual carrier ampholytes (20/pH unit) and at current densities that are used in CIEF, i.e., under conditions that were hitherto unaccessible by dynamic computer simulation. Having a focusing capillary of 5-cm length, the predicted focusing dynamics for amphoteric dyes obtained at a constant voltage of 1500 V (300 V/cm) are shown to qualitatively agree with data obtained by whole-column optical imaging. The simulation data provide detailed insight into the dynamics of the focusing process for the cases with the focusing column being sandwiched between 40 mM NaOH (catholyte) and 100 mM phosphoric acid (anolyte) or having the column ends only permeable for OH- and H+ at cathode and anode, respectively. Simulation data reveal that the number of sample boundaries migrating from the two ends of the column to the focusing positions is always equal to the number of sample components. The number of detectable migrating sample boundaries, however, can be lower. Whole-column optical imaging is demonstrated to be the method of choice for following the approach to equilibrium. With that detection format, transient sample peaks can be recognized and properly identified. This would also be possible with a scanning detector moving rapidly and repeatedly along the column but cannot be accomplished by a stationary detector placed at a specified location. The data presented demonstrate that the model together with imaging monitoring can be used to optimize the CIEF separation conditions.

Coloring Agents↗

Air sampling with porous solid-phase microextraction fibers

A new, rapid air sampling/sample preparation methodology was investigated using adsorptive solid-phase microextraction (SPME) fiber coatings and nonequilibrium conditions for volatile organic compounds (VOCs). This method is the fastest extraction technique for air sampling at typical airborne VOC concentrations. A theoretical model for the extraction was formulated based on the diffusion through the interface between the sampled (bulk) air and the SPME coating. Parameters that affect the extraction process including sampling time, air velocity, air temperature, and relative humidity were investigated with the porous (solid) PDMS/DVB and Carboxen/PDMS coatings. Very short sampling times from 5 s to 1 min were used to minimize the effects of competitive adsorption and to calibrate the extraction process in the initial linear extraction region. The predicted amounts of extracted mass compared well with the measured amounts of target VOCs. Findings presented in this study extend the existing fundamental knowledge related to sampling/sample preparation with SPME, thereby enabling the development of new sampling devices for the rapid sampling of air, headspace, water, and soil.

Journal Article↗

Time-weighted average sampling of volatile and semi-volatile airborne organic compounds by the solid-phase microextraction device.

The ultimate goal of the chemist is to perform sample preparation, and analysis, if possible at the place where a sample is located rather than moving the sample to laboratory, as is common practice in many cases at the present time. This approach eliminates errors and time associated with sample transport and storage and therefore it would result in more accurate, precise and faster analytical data. In addition to portability, two other important features of ideal field sample preparation technique are elimination of solvent use and integration with a sampling step. A method is developed which addresses these requirements for the determination of time-weighted average concentration of gas phase compounds using a solid-phase microextraction device. Quantification of target analytes in air using this method can be carried out without external calibration. The volatile and semi-volatile organic compounds in air diffuse into the fiber coating which is retracted a known distance into its needle housing during the sampling period. The coatings used are poly(dimethylsiloxane) and poly(dimethylsiloxane)-divinylbenzene. The sampling rate at which gas phase analytes load onto the fiber is determined for a wide range of hydrocarbons. There is a good agreement between the theoretical and experimental sampling rates. Sampling time ranges from 1 min to 24 h depending on the coating used and its retraction distance. Effect of the flow-rate on the uptake rate by the fiber is studied. The method is tested in the field and compared with National Institute of Occupational Health and Safety Method 1550. Good agreement between the results is obtained.

Chromatography↗

Determination of distribution constants between a liquid polymeric coating and water by a solid-phase microextraction technique with a flow-through standard water system

This paper describes an optimized experimental system for determining water/polymer coating distribution constants and discusses the mechanism of extraction of high molecular weight compounds by poly(dimethylsiloxane) (PDMS). The proposed flow-through standard water generator eliminates errors associated with both losses of analytes to the system surfaces and limited sample volume. In addition, the errors caused by partial precipitation or poor dissolution of highly hydrophobic analytes during spiking of water when producing calibration standards are also eliminated. The target analytes are a range of polycyclic aromatic hydrocarbons (PAHs). The results demonstrate that absorption partitioning is the predominant mechanism of extraction of analytes into PDMS-coated fibers for all PAHs investigated regardless of molecular weight. There is a strong correlation between determined PDMS/water distribution constants (K(fw)) and literature K(ow) values for all PAHs.

Journal Article↗

Evolution of solid-phase microextraction technology.

The main objective of this contribution is to describe the development of the concepts, techniques and devices associated with solid-phase microextraction, as a response to the evolution of understanding of the fundamental principles behind this technique. The discussion begins with an historical perspective on the very early work conduced almost a decade ago. As new fundamental understanding about the functioning of the technology developed, new ways of constructing and using the SPME devices evolved.

Chromatography, Liquid↗

In-tube solid-phase microextraction coupled to capillary LC for carbamate analysis in water samples.

Recently, the on-line sample preparation technique, intube solid-phase microextraction (SPME), was successfully implemented with a Hewlett-Packard 1100 HPLC system for analysis of carbamates in water samples. This paper describes the coupling of in-tube SPME to capillary LC and explores its utility as a sample preparation method in that format, relative to conventional LC. The Hewlett-Packard HPLC system was upgraded to a capillary LC system using commercially available accessories from LC Packings. The combination of in-tube SPME with a capillary LC system was expected to build on the merits of both in-tube SPME and the capillary LC to generate a sensitive method with an easy, effective, and efficient sample preparation. Due to the relatively large effective injection volume of the in-tube SPME technique (30-45 microL), on-column focusing was employed in order to achieve good chromatographic efficiency. Excellent sensitivity was achieved with very good method precision. For all carbamates studied, the RSD of retention time was between 0.5 and 0.8% under 4 microL/min microgradient conditions. The RSD of peak area counts was between 1.5 and 4.6%. The detection limits for all carbamates studied were less than 0.3 microg/L and, for carbaryl, just 0.02 microg/L (20 ppt). Compared with the conventional in-tube SPME/LC method, the LODs were lowered for carbaryl, propham, methiocarb, promecarb, chlorpropham, and barban, by factors of 24, 45, 42, 81, 62, and 56, respectively. The optimized method was successfully applied to the analysis of carbamates in surface water samples.

Carbamates↗

Applications of solid-phase microextraction in food analysis.

Food analysis is important for the evaluation of the nutritional value and quality of fresh and processed products, and for monitoring food additives and other toxic contaminants. Sample preparation, such as extraction, concentration and isolation of analytes, greatly influences the reliable and accurate analysis of food. Solid-phase microextraction (SPME) is a new sample preparation technique using a fused-silica fiber that is coated on the outside with an appropriate stationary phase. Analyte in the sample is directly extracted to the fiber coating. The SPME technique can be used routinely in combination with gas chromatography (GC), GC-mass spectrometry (GC-MS), high-performance liquid chromatography (HPLC) or LC-MS. Furthermore, another SPME technique known as in-tube SPME has also been developed for combination with LC or LC-MS using an open tubular fused-silica capillary column as an SPME device instead of SPME fiber. These methods using SPME techniques save preparation time, solvent purchase and disposal costs, and can improve the detection limits. This review summarizes the SPME techniques for coupling with various analytical instruments and the applications of these techniques to food analysis.

Food Analysis↗

Speciation of alkyllead and inorganic lead by derivatization with deuterium-labeled sodium tetraethylborate and SPME-GC/MS.

A method for full speciation and determination of alkyllead and inorganic lead(II) in aqueous samples was developed. This was accomplished by in situ derivatization with deuterium-labeled sodium tetraethylborate NaB(C2D5)4 (DSTEB). The derivatization was carried out directly in the aqueous sample and the derivatives were extracted from the headspace by a solid-phase microextraction (SPME) fiber. The extracted analytes were then transferred to a GC/MS or a GC/FID for separation and detection. The research presented demonstrates that SPME and the derivatization reagent DSTEB can be used successfully for the speciation of Pb2+, Pb(CH3)3+, Pb(C2H5)3+, and Pb(C2H5)4 in water samples. All derivatives, Pb(C2D5)4, (CH3)3Pb(C2D5), (C2H5)3Pb(C2D5), and Pb(C2H5)4, are separated using an SBP-5 column. This method was applied to monitor degradation of tetraethyllead in water. This is the first report of ethylation by DSTEB for full speciation of methyllead, ethyllead, and inorganic lead compounds. This approach can be extended to other organometallic compounds as demonstrated for ethyltin speciation. This full speciation method will aid in monitoring occurrence, pathways, toxicity, and biological effects of these compounds in the environment. It is easily adopted for field analysis.

Borates↗

Determination of butyltin species in water and sediment by solid-phase microextraction-gas chromatography-flame ionization detection.

A procedure for determination of tetraethyltin (TeET) and tetrabutyltin (TeBT) in water by solid-phase microextraction (SPME) using the headspace approach has been developed. The method has been adapted for the simultaneous determination of mono-, di- and tributyltin species (MBT, DBT and TBT) after derivatization with sodium tetraethylborate in water and sediment samples. The analytical procedures were optimized with respect to stirring conditions, extraction time and extraction temperature. The pH and the amount of derivatizing reagent were also considered in derivatization reaction procedures. The analysis was carried out using gas chromatography equipped with flame ionization detection. The detection limits obtained for TeET and TeBT, in equilibrium conditions (room temperature for TeET and 40 degrees C for TeBT) were 28 and 20 ng/l (as Sn), respectively. The detection limit for butyltin species in water, which was limited by signals which are non-specific for the tin compounds and the sensitivity of the FID system, was found ca. 1 microg/l (as Sn). The SPME method was validated for analysis of sediments by analyzing the certified reference material PACS-2 finding a good agreement with the certified values.

Calibration↗

Automated in-tube solid-phase microextraction-high-performance liquid chromatography for carbamate pesticide analysis.

In-tube solid-phase microextraction (SPME) is an automated version of SPME that can be easily coupled to a conventional HPLC autosampler for on-line sample preparation, separation and quantitation. It has been termed "in-tube" SPME because the extraction phase is coated inside a section of fused-silica tubing rather than coated on the surface of a fused-silica rod as in the conventional syringe-like SPME device. The new in-tube SPME technique has been demonstrated as a very efficient extraction method for the analysis of polar and thermally labile analytes. The in-tube SPME-HPLC method used with the FAMOS autosampler from LC Packings was developed for detecting polar carbamate pesticides in clean water samples. The main parameters relating to the extraction and desorption processes of in-tube SPME (selection of coatings, aspirate/dispense steps, selection of the desorption solvents, and the efficiency of desorption solvent, etc.) were investigated. The method was evaluated according to the reproducibility, linear range and limit of detection. This method is simple, effective, reproducible and sensitive. The relative standard deviation for all the carbamates investigated was between 1.7 and 5.3%. The method showed good linearity between 5 and 10000 microg/l with correlation coefficients between 0.9824 and 0.9995. For the carbamates studied, the limits of detection observed are lower than or similar to that of US Environmental Protection Agency or National Pesticide Survey methods. Detection of carbaryl present in clean water samples at 1 microg/l is possible.

Carbamates↗