Evolution of solid-phase microextraction technology.

Abstract

The main objective of this contribution is to describe the development of the concepts, techniques and devices associated with solid-phase microextraction, as a response to the evolution of understanding of the fundamental principles behind this technique. The discussion begins with an historical perspective on the very early work conduced almost a decade ago. As new fundamental understanding about the functioning of the technology developed, new ways of constructing and using the SPME devices evolved.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Lord, J Pawliszyn. 2000-07-14. Evolution of solid-phase microextraction technology.. https://doi.org/10.1016/s0021-9673(00)00535-5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Sensitive and specific liquid chromatographic-tandem mass spectrometric assay for dihydroergotamine and its major metabolite in human plasma.

A sensitive and specific procedure for the simultaneous determination of dihydroergotamine (DHE) and its 8'-hydroxylated metabolite (8'-OH-DHE) in human plasma was developed and validated. The analytes were extracted from plasma samples by liquid-liquid extraction, separated through a Zorbax C18 column (50x2.1 mm I.D.) and detected by tandem mass spectrometry with an electrospray ionization interface. Caroverine was used as the internal standard. The method has a lower limit of quantitation (LOQ) of 10.0 and 11.0 pg/ml for DHE and 8'-OH-DHE, respectively. The intra- and inter-run precision was measured to be below 9.1% for both DHE and 8'-OH-DHE. The inter-run accuracy was within 4% for the analytes. The overall extraction recoveries of DHE and 8'-OH-DHE were determined to be about 58 and 52% on average, respectively. The chromatographic run time was approximately 2.5 min. More than 120 samples could be assayed daily with this method, including sample preparation, data acquisition and processing. The method developed was successfully used to investigate plasma concentrations of DHE and 8'-OH-DHE in a pharmacokinetic study of volunteers who received DHE orally.

Chromatography, Liquid↗

The investigation and the use of high flow column-switching LC/MS/MS as a high-throughput approach for direct plasma sample analysis of single and multiple components in pharmacokinetic studies.

Recently direct plasma injection LC/MS/MS technique has been increasingly used in pharmaceutical research and development due to the demand for higher throughput of sample analyses. In this work, two on-line extraction methods including high flow LC/MS/MS and high flow column switching LC/MS/MS were investigated. The evaluations were conducted and focused on their performances with respect to peak responses, separation efficiency, and signal to-noise ratio in a multiple-component LC/MS/MS assay. Two HPLC pumps were used-with one for high flow delivery and one for gradient elution. A CTC autosampler was used to inject plasma samples. High flow LC was achieved by the use of 4 ml/min flow rate on a 1 x 50 mm Waters Oasis column. A 2 x 100 mm YMC column was coupled via a column-switching valve. The extracted analytes were analyzed in multiple-reaction-monitoring (MRM) mode using a triple quadrupole MS/MS. As a rapid and simple procedure, vortex-mixing plasma and internal standard directly in sample vials completed sample preparation. The high flow column switching method (two-column system) provided sharper peak shape than the conventional high flow method. This effect increased analyte signal-to-noise ratio and sensitivity. Narrower peak width resulted in much better separation efficiency, which was required for multiple compound (N-in-1) analysis. A 2 mm I.D. column resulted in better peak shape and resolution than using a smaller I.D. column. The selected method achieved acceptable recoveries for most of the compounds tested, and it was successfully applied to a 10-in-1 pharmacokinetic (PK) study. The results showed that the dynamic range, lower limit of quantitation, assay accuracy and precision were acceptable for all compounds. Rapid sample preparation eliminated labor intensive and time consuming processes and improved productivity. This high throughput on-line extraction high flow column switching method has been proven particularly useful for multiple component analysis in PK studies.

Chromatography, Liquid↗

Screening approach for chiral separation of pharmaceuticals. Part I. Normal-phase liquid chromatography.

A strategy for rapid screening for the separation of chiral molecules of pharmaceutical interest by normal-phase liquid chromatography using three cellulose/amylose stationary phases is proposed. In a first step, the most important parameters for the separations were determined and studied for their effects by means of experimental designs. Results showed that the cellulose tris-(3,5-dimethylphenylcarbamate), the amylose tris-(3,5-dimethylphenylcarbamate) and the cellulose tris-(4-methylbenzoate) stationary phases have very broad and complementary enantiorecognition properties. The type of organic modifier used in the mobile phase appeared to have a dramatic influence on the quality of the separation. Based on the results of the preliminary study, a screening strategy was developed and successfully applied to a set of 36 diverse drugs. Enantiomeric separation was observed in 89% of cases and the analysis times were usually shorter than 20 min.

Chromatography, Liquid↗