PubMed Health⌕ Search

Biomedical subjects

J Rayfield

Publications and source records attributed to J Rayfield.

4 recordsLinked to original sources

The lack of standardization of cardiac troponin I assay systems.

The lack of standardization of cardiac troponin I (cTnI) assay systems has meant an inability to compare absolute values between methods, and non-traceability of cTnI measurement in clinical laboratories. The present study tested whether a common calibrator for cTnI would harmonize values between different methods. Twenty fresh-frozen plasma samples and a common calibrator were analyzed in duplicate using the Dade Behring Stratus II, Chiron ACS:180, Abbott AxSYM, and Beckman Coulter Access immunoassay systems. Uncorrected cTnI values varied up to 60-fold between systems, and when correlated to the Stratus, linear regression slopes were 0.97 (ACS:180), 4.86 (AxSYM), and 0.03 (Access), verifying the differences in calibration. After correction for calibration differences by reference to the common calibrator, among-assay CV ranged from 2.7% to 55%, and was >25% for eight samples. However, the exclusion of Access results reduced the CV to 32% with only four outliers. The results show that comparable cTnI values between methods are possible by the use of a common calibrator. The lack of method harmonization for some samples may be due to non-equal antibody immunoreactivity of different plasma cTnI forms. The complete standardization of cTnI measurement requires both a secondary reference material and standardization of manufacturers' cTnI antibodies.

Clinical Chemistry Tests↗

A simple quality control protocol for haemoximetry using standard p50.

We have designed a quality control tool for haemoximetry using the principle that standard p50, calculated from blood gas and haemoximetry measurements using the Siggaard-Andersen algorithm, remains unchanged when a specimen of venous blood is oxygenated progressively to 97% saturation of haemoglobin. If the haemoximeter is inaccurate, progressively larger deviations of standard p50 from the constant value occur above 80% saturation. Deviations too small to be detected by analysis of quality control materials comprised of non-haemoglobin dyes and yet sufficient to cause significant errors in derived extractivity parameters can be detected by this method. The suggested protocol is easy to perform, and is recommended as a quality control tool for blood gas analyser/haemoximeters used to determine arterial extractivity parameters.

Algorithms↗

Focus on needs.

Explore the source record for details and available documents.

Activities of Daily Living↗

Express yourselves.

Explore the source record for details and available documents.

Aged↗