Effect of a soluble ionic polymer on the separation of anions by capillary electrophoresis.

A silica capillary for CE analysis of anions can be conditioned with NaOH, rinsed with water, coated with a cationic polymer, and equilibrated with the background electrolyte in only 2 min for each of the four steps. The coated surface has a positive charge that gives a substantial anodic electroosmotic flow (EOF) over the range of pH 2.5-12.0. The migration times of sample anions and a neutral marker (used for EOF calculations) are generally reproducible to an RSD of 1% or better, both for successive runs on a single capillary and from capillary to capillary. It was shown that the type of buffer used affects the EOF of a coated capillary. A concentration of 100 mM or higher sodium chloride minimizes differences in EOF with different buffers and also gives sharper peaks for sample anions.

Anions↗

A mechanism of separation in electrostatic ion chromatography.

The retention mechanism of electrostatic ion chromatography (EIC) is currently under debate and is the focus of this paper. A comprehensive set of retention data has been obtained on a C18 column coated with the zwitterionic surfactant 3-(N,N-dimethylmyristylammonio)propanesulfonate used with a range of mobile phases in which both the mobile-phase anion and cation have been varied systematically. Electro-osmotic flow measurements were also obtained on fused-silica capillaries coated with the zwitterion (and also some monofunctional surfactants) and were used to evaluate the nature of the surface charge on the layer of adsorbed surfactant in the presence of various background electrolytes. A new retention mechanism for EIC was developed on the basis of these data. This mechanism proposes that equilibration of the bound zwitterions with a mobile phase containing a suitable electrolyte causes the establishment of a charged layer created by the terminal sulfonate groups of the zwitterion, which acts as a Donnan membrane. The magnitude and polarity of the charge on this membrane depends on the nature of the mobile-phase ions. The Donnan membrane exerts weak electrostatic repulsion or attraction effects on analyte anions. A second component of the retention mechanism is chaotropic interaction of the analyte anion with the quaternary ammonium functional group of the zwitterion. This interaction exerts the major effect on the separation selectivity of EIC, such that analyte anions are eluted in order of increasing chaotropic interactions in accordance with the Hofmeister series.

Journal Article↗

Optimisation of the separation of anions by ion chromatography-capillary electrophoresis using indirect UV detection.

The separation of a complex mixture of inorganic and organic anions by ion chromatography-capillary electrophoresis using a cationic polymer added to the background electrolyte and indirect UV detection has been studied. The addition of unmodified polymer to an electrolyte suitable for indirect detection resulted in the appearance of a system peak due to the counter-anion on the polymer and while the position of the analytes relative to this system peak could be changed, this was found to be an unacceptable approach for mixtures of large numbers of analytes. Although conversion of the polymer to replace the counter-ion with the indirect UV detection probe ion simplified the system, this approach restricted the flexibility of the system because the probe and polymer concentration were necessarily linked. This limitation could be overcome by selecting the appropriate type of probe ion, with probes having a low ion-exchange selectivity coefficient providing greater retention of analytes than probes with a high ion-exchange selectivity coefficient. Three electrolyte systems with different probes (benzoate, chromate and phthalate) were modelled using a previously derived migration equation and this was used to optimise the electrolyte composition to enable the separation of a mixture of 24 inorganic and organic anions within 7 min. The electrolyte composition was then optimised for the analysis of anions in Bayer liquor with the final separation selectivity being substantially improved for selected key analytes.

Anions↗

Manipulation of separation selectivity of inorganic anions in electrostatic ion chromatography by the use of mixed cationic-zwitterionic micelles as the column coating solution.

This paper describes an electrostatic ion chromatographic system in which the separation selectivity for inorganic anions, especially for sulfate and phosphate, could be manipulated by altering the molar ratio of the zwitterionic and cationic surfactants in the column coating solution used to prepare the stationary phase. The zwitterionic surfactant used for this study was 3-(N,N-dimethyltetradecylammonio)propanesulfonate (Zwittergent-3-14) and the cationic surfactant was tetradecyltrimethylammonium (TTA). Using a reversed-phase C18 column (250x4.6 mm I.D.) coated with 10/10 (mM/mM) of TTA/Zwittergent-3-14 mixed micelles as the stationary phase and either NaHCO3 or Na2CO3 aqueous solution as the eluent, together with suppressed conductivity detection, baseline separation of seven model inorganic anions was obtained. The elution order for those anions was found to be F+ < HPO4(2-) < Cl- < SO4(2-) < NO2- < Br- < NO3-. Under the same conditions but using 1/10 (mM/mM) of TTA/Zwittergent-3-14 mixed micelles as the column coating solution, the elution order for these model ions was F- < HPO4(2-) < SO4(2-) < Cl- < NO2- < Br- < NO3-. The early elution of phosphate and sulfate is a unique attribute of this system. Detection limits for F-, HPO4(2-), Cl-, SO4(2-), NO2-, Br- and NO3- (S/N=3, sample injection volume 100 microl) were 0.11, 0.12, 0.12, 0.18, 0.49, 0.49, 0.52 microM, respectively.

Anions↗

High-performance ion-exclusion/cation-exchange chromatography of anions and cations in acid rain waters on a weakly acidic cation-exchange resin.

A new method for the simultaneous determination of anions (sulfate, nitrate, and chloride) and cations (sodium, ammonium, potassium, magnesium, and calcium) in acid rain waters was investigated using high-performance ion-exclusion/cation-exchange chromatography with conductimetric detection on a separation column packed with a polymethacrylate-based weakly acidic cation-exchange resin in the hydrogen-form and an eluent comprising 1.5 mM sulfosalicylic acid-6 mM 18-crown-6 at pH 2.6, operated at 1.5 ml/min. Effective separation and highly sensitive conductimetric detection for the anions and the cations was achieved in about 14 min. Since the ionic balance (equivalents of anions/equivalents of cations) of acid rain waters of different pH (4.40-4.67) ranged from 0.97 to 0.94, evaluation of the water quality of acid rain was possible. This method was successfully applied to the simultaneous determination of the anions and the cations in acid rain transported from mainland China and North Korea to central Japan monitored by a meteorological satellite data analyzer.

Acid Rain↗

Miniaturized solid-phase extraction with resin disks.

The properties and advantages of membrane disks for solid-phase extraction (SPE) are described. Miniaturization is a trend in SPE, as well as chemical analysis in general. A semimicro method is reviewed in which an extraction disk 4 mm in diameter is used for SPE. Even smaller scale separations are possible with a device in which a membrane 0.7 mm in diameter was incorporated into the needle of a 50-micro syringe. Aqueous samples containing 10 ppb of eight substituted benzenes were passed through the miniaturized-SPE syringe automatically using a single-syringe infusion pump. Elution volumes of 5 microl provided 500-fold concentrations and delivered average recoveries greater than 90% and an average relative standard deviation (RSD) of 4.6% for the analytes. Direct injection of the 5 microl eluate from the miniaturized-SPE syringe into a gas chromatograph also produced average recoveries greater than 90% and an average RSD of 6.2%.

Benzene Derivatives↗

Determination of inorganic anions in human saliva by zwitterionic micellar capillary electrophoresis.

Capillary electrophoresis (CE) using sulfobetaine-type zwitterionic micelles as the background electrolyte (BGE) has been used to determine inorganic anions in human saliva. The zwitterionic micelles resulted in unique migration behavior for the separation of inorganic anions. They also prevented adsorption of proteins on the inner wall of the capillary. These properties of the zwitterionic micelles enabled the direct determination of inorganic anions in human saliva. Three species of inorganic anions, NO2-, NO3-, and SCN-, were found in real samples and the analysis was achieved within 3 min. Direct UV-absorption was used as the detection method and the detection limits for these anions were 2.0, 1.0, and 5.0 micromol L(-1), respectively (0.09, 0.06, and 0.30 microg mL(-1)).

Anions↗

Determination of inorganic acids by ion chromatography with n-tetradecylphosphocholine (zwitterionic surfactant) as the stationary phase and pure water as the mobile phase.

A new ion chromatographic (IC) system, in which n-tetradecylphosphocholine (TDPC, a phosphobetaine type of zwitterionic surfactant) was used as the stationary phase, pure water as the mobile phase, and conductivity as the method of detection, has been developed for the determination of inorganic acids. Five model acids, HCl, HNO3, HClO4, H2SO4, and H3PO4, were separated to baseline and eluted in the order H3PO4 > HCl > HNO3 > H2SO4 > HClO4. When peak areas were plotted against the concentrations of the acids in samples, linear calibration curves were obtained. Ultimate determination limits were approximately 1 mmol L(-1), but the discrimination of the method between solutions of different concentration was better than 10 micromol L(-1) for those model analytes. Salts of divalent cations could also be separated, but they were eluted faster than the acids. No separation was observed for the salts of monovalent cations. This newly proposed approach is applicable to the simultaneous determination of the inorganic acids (produced by reactions of NOx, SOx, and HCl with water) in aerosols.

Acids↗

Recent developments in the separation of inorganic and small organic ions by capillary electrophoresis.

Which method should I use for ion analysis, ion chromatography (IC) or capillary electrophoresis (CE)? In terms of actual theoretical plates CE has a clear-cut advantage. The separation ability of IC is adequate for many sample types, and many separation scientists feel that IC offers greater reliability and confidence than CE. However, IC is a more mature technique and there has been more time to solve problems such as peak tailing and to improve reproducibility. The two techniques should be viewed as complementary. A number of recent developments in ion analysis by CE are discussed. These include some simple ways to control electroosmotic flow and improve reproducibility, separation of isotopes, improved methods of indirect photometric detection, a new contactless conductivity detector, separation of ions at low pH, and in solutions of high salt content. Progress in a new technique called IC-CE will be described in which a soluble ion-exchange polymer is added to the capillary electrolyte to separate anions based on differences in both electrophoretic mobility and ion-exchange interactions.

Electrophoresis, Capillary↗

Simultaneous ion-exclusion/cation-exchange chromatography of anions and cations in acid rain waters on a weakly acidic cation-exchange resin by elution with sulfosalicylic acid.

A simple, selective, and sensitive method for the simultaneous determination of anions (sulfate, nitrate, and chloride) and cations (sodium, ammonium, potassium, magnesium, and calcium) in acid rain waters was developed using ion-exclusion/ cation-exchange chromatography with conductimetric detection. A weakly acidic cation-exchange resin column (Tosho TSKgel OA-PAK-A) and a sulfosalicylic acid-methanol-water eluent was used. With a mobile phase comprising 1.25 mM sulfosalicylic acid in methanol-water (7.5:92.5) at 1.2 ml/min, simultaneous separation and detection of the above anions and cations was achieved in about 30 min. Linear calibration plots of peak area versus concentration were obtained over the concentration ranges 0-1.0 mM for anions (R=0.9991) and 0-0.5 mM for cations (R=0.9994). Detection limits calculated at S/N=3 ranged from 4.2 to 14.8 ppb for the anions and from 2.4 to 12.1 ppb for the cations. The reproducibility of retention times was 0.14-0.15% relative standard deviation (RSD) for anions and 0.18-0.31% for cations, and reproducibility of chromatographic peak areas was 1.22-1.75% RSD for anions and 1.81-2.10% for cations. The method was applied successfully to the simultaneous determination of anions and cations in aerosols transported from mainland China to central Japan, as determined by a meteorological satellite data analyzer.

Anions↗

Separation of anions by ion chromatography-capillary electrophoresis.

Capillary electrophoresis (CE) with a water-soluble ion-exchange polymer in the background electrolyte is very efficient for the separation of organic and inorganic anions because the ion-exchange selectivity, as well as differences in electrophoretic mobility, can be used for separating sample ions. Poly(diallyldimethylammonium chloride) (PDDAC) was employed for this purpose. A very stable electroosmotic flow was obtained between pH 2.3 and 8.5 due to the strong adsorption of PDDAC onto the capillary wall. The effect of ion exchange on the migration of sample anions and their separation was controlled by varying the concentration of PDDAC, the concentration and the type of salt used in the CE background electrolyte. Addition of organic solvent (e.g., acetonitrile) could also modify the sample migration and the separation. Baseline separations were obtained for anions with very similar mobilities, such as bromide and iodide, naphthalenesulfonates, and bi- and tricarboxylic acids. Typical separation efficiencies were between 195,000 and 429,000 theoretical plates per meter. Ten replicate separations gave an average RSD of 1.0% for migration times of the sample anions studied. Excellent separations were obtained for a variety of samples, including a separation of 17 inorganic and organic anions in less than 6 min.

Anions↗

Modelling and optimization of the separation of anions in ion chromatography--capillary electrophoresis.

The influence of varying experimental conditions on the mobilities of inorganic and organic anions in ion chromatography-capillary electrophoresis (IC-CE) was studied. A theoretical model derived from both IC and CE was used to explain the influence on analyte mobility caused by varying the concentration of polymer and increasing the salt concentration in the background electrolyte. The influence of the type of competing ion was also accounted for by including the analyte selectivity coefficient in the model equation. The validity of the model was shown using electrolyte systems containing four different competing anions, with correlation between experimental and mobilities predicted being excellent (r2 > 0.98) for all systems. Selectivity coefficients determined via nonlinear regression enabled quantitative comparisons of different competing ion strength, with the eluting strength increasing in the order of fluoride, acetate, chloride, and sulfate. Optimization of the polymer and eluent concentration was performed for all electrolyte systems using the normalized resolution product optimization criterion, requiring only seven experiments to obtain the optimum conditions for complete separation. The minimum resolution criterion was used to optimize the fluoride system which gave a different separation selectivity from both CE and IC.

Anions↗

Analysis of inorganic anions by electrostatic ion chromatography using zwitterionic/cationic mixed micelles as the stationary phase.

The inability to separate fluoride, phosphate and sulfate by electrostatic ion chromatography (EIC) was overcome by using an ODS silica column coated with mixed zwitterionic-cationic surfactants as the stationary phase. The best results were obtained using the zwitterionic surfactant, 3-(N,N-dimethylmyristylammonium)-propanesulfonate (C19H41NO3S), and the cationic surfactant, myristyltrimethylammonium, CH3(CH2)13N+(CH3)3, in a 10:1 molar ratio in the column coating solution. With a dilute solution of sodium tetraborate as the eluent the model analyte anions were completely separated in the following elution order: F, HPO42-, SO42-, Cl-, NO2-, Br-, NO3-. The very early elution of phosphate and sulfate is most unusual and is unique to this system. Detection limits better than 1.1 x 10(-4) mM and linear calibration plots up to 7.0 mM were obtained with a suppressed conductivity system.

Journal Article↗

Acid-rain monitoring in east Asia with a portable-type ion-exclusion-cation-exchange chromatographic analyzer.

A monitoring system consisting of a portable-type conductimetric ion-exclusion-cation-exchange chromatographic (CEC) analyzer and a meteorological satellite data analyzer has been investigated for the evaluation of the effects of acid precipitation on natural and urban environments in East Asia. The portable ion-exclusion-CEC analyzer uses a polymethacrylate-based weakly acidic cation-exchange resin column in the H(+)-form and a weak-acid eluent (tartaric acid-methanol-water) and is applied for the simultaneous determination of anions (SO4(2)-, NO3-, and Cl-) and cations (Na+, NH4+, K+, Mg2+, and Ca2+) in precipitation transported from mainland China to central Japan, as mapped by the meteorological satellite data analyzer. Linear calibration graphs of peak area versus concentration for anions and cations were observed in the concentration range 0-1.0 mM for the anions and 0-0.5 mM for the cations. Detection limits at a signal-to-noise ratio of 3 were in the range 5.18-12.1 ppb for the anions and 6.58-16.5 ppb for the cations. The practical utility of this monitoring system is presented.

Acid Rain↗

Nonaqueous media for separation of nonionic organic compounds by capillary electrophoresis.

For the separation of neutral compounds by micellar electrokinetic chromatography, separations are usually carried out in predominantly aqueous solution in order to preserve the charged micelle necessary for the separation. We now show that polycyclic aromatic hydrocarbon (PAH) compounds can be separated efficiently by capillary electrophoresis in pure methanol or in aqueous-organic mixtures containing a high percentage of methanol. Sodium tetradecyl sulfate was the preferred surfactant. The effects of pH, solvent composition, surfactant structure, and surfactant concentration on the separations were studied. Reproducible migration times and linear calibration plots were obtained.

Electrophoresis, Capillary↗

High-performance liquid chromatographic determination of drugs and metabolites in human serum and urine using direct injection and a unique molecular sieve.

Silicalite is a molecular sieve that contains an intricate system of channels approximately 6 A in diameter. These channels are hydrophobic and have been shown to retain relatively small hydrophobic and hydrophilic molecules from aqueous and biological samples. Silicalite is shown to be a restricted-access medium that permits the injection of biological fluids directly onto a HPLC column packed with Silicalite, eliminating the need for sample preparation. The sample macromolecules elute with high recovery mostly at the extraparticulate void. Simultaneously, Silicalite allows various drugs and metabolites to enter the channels and be retained. Recoveries >90% were generally obtained for a wide variety of drugs and their metabolites from human serum and urine.

Blood↗

Ion-exchange chromatography of mono- and divalent cations in natural waters on a weak-acid anion-exclusion column.

Ion-exchange chromatography with indirect conductimetric detection for the simultaneous determination of mono- and divalent cations is investigated using an anion-exclusion chromatographic column packed with polymethacrylate-based weakly acidic cation-exchange resin in the H+ form (Tosoh TSKgel OA-PAK-A, 300 mm x 7.8 mm I.D.). An eluent comprising a strong acid, a weak organic acid, methanol and water is used. Using 0.75 mM sulfuric acid, 2 mM tartaric acid, 7.5% (v/v) methanol in water as eluent, the monovalent cations (Na+, NH4+, and K+) and divalent cations (Mg2+ and Ca2+) were separated simultaneously by a cation-exchange mechanism in about 25 min. The application of this method to the analysis of several natural waters including rain, river, lake, underground and forest soil waters for estimating acid rain effects on the natural and urban environments is presented.

Acid Rain↗

Capillary electrophoresis of anions at high salt concentrations.

It is commonly thought that even a moderately high ionic concentration in the background electrolyte (BGE) would lead to Joule heating and serious peak distortion. However, we obtained very satisfactory separations of both inorganic and organic anions in electrolyte solutions as high as 5 M sodium chloride using direct photometric detection. Samples containing a 0.5 M concentration of a salt can be analyzed directly by making the BGE concentration of the same salt even higher to obtain electrostacking. The temperature in the center of the capillary was calculated to be 49 degrees C when the current is at its maximum of 280 microA. The effect of various salts on electrophoretic and electroosmotic mobility is discussed. Several examples are given of capillary electrophoresis under high-salt conditions.

Anions↗