PubMed Health⌕ Search

Biomedical subjects

J Schmittner

Publications and source records attributed to J Schmittner.

3 recordsLinked to original sources

Pupillometry in the detection of concomitant drug use in opioid-maintained patients.

Pupillometry and ocular response measures are sensitive to a variety of acutely administered drugs and as such are useful for drug detection and fitness-for-duty applications. The utility of pupillometry to complement urine testing in methadone clinics, where there is considerable non-therapeutic drug use, has not been tested. A video-based pupillometer (FIT 2000) was evaluated in 37 opioid-maintained patients. Three times a week they provided urine samples and pupillometry measures of: initial diameter (ID) in mm; constriction amplitude (CA) in mm; constriction latency (CL) in msec; and saccadic velocity (SV) in mm/sec. Analysis of the success rates indicated that 92.9% of subjects obtained an acceptable reading, 59% on the first attempt. Low variability in pupillary parameters on drug-free days are necessary for effective identification of concomitant drug use. The variability (standard deviation) of ID (0.51 vs. 0.68), CA (0.12 vs. 0.27) and SV (7.2 vs. 11.1) increased on days when the urine was positive for abused drugs compared with drug-free urine days in subjects (n = 6). Subjects who were always drug-free (n = 4) had lower variability than those who always had urine positive for additional drugs (n = 20). These preliminary results suggest that pupillometry may be useful to verify concomitant drug use in a methadone-maintained population. Successful implementation of the methodology could reduce costly and intrusive urine testing.

Adult↗

Can patients use an automated questionnaire to define their current health status?

Patient management decisions rarely incorporate standardized health status assessments, since accurate and reliable measures are difficult and expensive to obtain. In prior research with various methods for obtaining health data from patients, it was found that physicians' acceptance of a method was improved if it provided an individualized printout. It was also determined that patients will readily complete a health status questionnaire on a computer when the computer does not look like a computer. Patients' acceptance was greatest when they were presented with a single line of large, pressure-sensitive buttons with which they could respond to questions about their health histories. Using such an instrument, the HealthQuiz, the current study found the same discrepancy rate (3%) between patients' responses to health questions presented on HealthQuiz and during interview as between their responses to questions asked during two separate interviews. Further, to ascertain health status, rules determined by an expert panel were applied to patients' responses to health questions presented on the HealthQuiz screen. It was found that the numerical health status derived from answers to the automated presentation of questions was similar to numerical health status derived by a physician after a patient-physician interview.

Aged↗