MRI of the abnormal cervical spinal cord using 2D spoiled gradient echo multiecho sequence (MEDIC) with magnetization transfer saturation pulse. A T2* weighted feasibility study.

OBJECTIVES: The aim of this study was to assess the potential of heavily T2* weighted 2D spoiled gradient echo multiecho sequence MEDIC (multi echo data image combination) with magnetization transfer saturation pulse (MTS) for detecting abnormality of the cervical spinal cord. METHODS: 11 patients, 5 women and 6 men aged from 14 to 79 years (mean age 51.18 years), with traumatic, hemolytic-hemorrhagic or neoplastic diseases of the cervical spinal cord were examined with MRI. In cases with suspected myelopathy, the feasibility of the 2D spoiled gradient echo multiecho sequence MEDIC with MTS was evaluated in comparison with the results of spin echo T1W, spin echo T2W, multi echo (TSE in our case) and spin-echo multi-echo technique with magnetization preparation (turbo inversion recovery--TIR--in our case) sequences. RESULTS: Distortion of the "H" sign was found in all but one case. Hemorrhage was best shown by MEDIC, massive edema was very well visible using MEDIC, TIR and TSE T2W, whereas mild edema was visible with MEDIC only. CONCLUSIONS: Our preliminary experience in 11 patients shows that MEDIC can be used for the diagnosis of cervical spinal cord pathology.

Adolescent↗

[Evaluation of the Internet presence of diagnostic radiology units at German universities].

PURPOSE: Analyzing the availability and the contents of the internet homepages of the radiological departments of German universities. MATERIAL AND METHOD: In June and July 2001 the internet homepages of 36 radiological departments of German universities were evaluated in a study. A medical student experienced in using the world wide web examined the websites concerning the following criteria: research, teaching, informations for patients, clinical topics and general information. Additionally an evaluation of the technical standard of the presentation was performed. RESULTS: 31 of the 36 radiological departments presented a homepage in the world wide web. The subject research was presented by 29 institutes. Also 29 departments provided information concerning teaching in their presentations. In 24 cases informations especially for patients were given. In all topics there is a huge variety of the quality and quantity of the provided information throughout the different institutions. 21 homepages available without restriction during the study period; 3 were nearly completely under construction. Multimedia techniques were only used in 2 homepages. The structural hierarchy of the webpages was in the average only two or three levels. Only 6 providers presented an additional version of their homepage in english. CONCLUSION: In the moment the possibility of internet-presentation is sub-optimal used by the responsible persons of the radiological institutions. The main emphasis is on research and teaching. There is nearly no use of multimedial elements in the presentations. Only a minority of the homepages can be read by international viewers because of the lack of an english version of the pages.

Germany↗

MR imaging of cranial nerve lesions using six different high-resolution T1- and T2(*)-weighted 3D and 2D sequences.

PURPOSE: To find a suitable high-resolution MR protocol for the visualization of lesions of all 12 cranial nerves. MATERIAL AND METHODS: Thirty-eight pathologically changed cranial nerves (17 patients) were studied with MR imaging at 1.5 T using 3D T2*-weighted CISS, T1-weighted 3D MP-RAGE (without and with i.v. contrast medium), T2-weighted 3D TSE, T2-weighted 2D TSE and T1-weighted fat saturation 2D TSE sequences. Visibility of the 38 lesions of the 12 cranial nerves in each sequence was evaluated by consensus of two radiologists using an evaluation scale from 1 (excellently visible) to 4 (not visible). RESULTS: The 3D CISS sequence provided the best resolution of the cranial nerves and their lesions when surrounded by CSF. In nerves which were not surrounded by CSF, the 2D T1-weighted contrast-enhanced fat suppression technique was the best sequence. CONCLUSIONS: A combination of 3D CISS, the 2D T1-weighted fat suppressed sequence and a 3D contrast-enhanced MP-RAGE proved to be the most useful sequence to visualize all lesions of the cranial nerves. For the determination of enhancement, an additional 3D MP-RAGE sequence without contrast medium is required. This sequence is also very sensitive for the detection of hemorrhage.

Contrast Media↗

Evaluation of arterial bypass grafts of the pelvic and lower extremities with gadolinium-enhanced magnetic resonance angiography: comparison with digital subtraction angiography.

RATIONALE AND OBJECTIVES: The aim of this study was to compare contrast-enhanced magnetic resonance angiography (CE MRA) with digital subtraction angiography (DSA) in the assessment of patency and stenoses in bypass grafts. METHODS: Fifteen patients were examined with both CE MRA and DSA. Fifteen bypass grafts were evaluated by four readers for potential stenosis in five locations. The stenoses were classified in five types: 1 (0% to 24% stenosis), 2 (25% to 49%), 3 (50% to 74%), 4 (75% to 99%), and 5 (occlusion). RESULTS: Using both techniques, 70 of 75 evaluated locations (93.3%) were classified identically. This included six stenoses < 50% and six stenoses > 50%, respectively. Four of five overestimations of stenoses were scaled in DSA as stenoses type 1. One stenosis was categorized as type 3 in DSA. Sensitivity for CE MRA for detecting stenoses >or= 25% was 100% and the specificity 90%. Interobserver agreement for all evaluations was 0.77 (Spearman rank correlation test). CONCLUSION: In the assessment of low-grade stenosis in bypass grafts, CE MRA overestimates stenoses slightly but yields good results in comparison with DSA.

Angiography, Digital Subtraction↗

Comparison of 2-D turbo spin echo and 3-D gradient echo sequences for the detection of the trigeminal nerve and branches anatomy.

The aim of this study was to assess the detectability of the trigeminal nerve and its branches using T1 weighted (w.) 3-D magnetization prepared rapid gradient echo (MP-RAGE), T2* w. 3D CISS and T2 w. 2-D turbo spin echo MR sequences. Thirty healthy volunteers were examined for this purpose using a 1.5 Tesla MR unit. The detectability of the trigeminal nerve and Gasser's Ganglion, i.e. structures that are surrounded by liquor was best using 3-D CISS. In the case of the ophthalmic, maxillary and mandibular nerves, the T1 w. 3-D MPRAGE was significantly better than T2* w. CISS and T2 w. 2-D turbo spin echo. The latter yielded the poorest results. We conclude that both high resolution T2* w. and T1 w. 3-D sequences are necessary in order to detect the liquor-surrounded trigeminal nerve and its soft tissue-surrounded branches. We would therefore recommend the inclusion of constructive interference in steady state (CISS) and MP-RAGE in a MR imaging protocol of the trigeminal nerve and its branches.

Adult↗

Comparison of two-dimensional gradient echo, turbo spin echo and two-dimensional turbo gradient spin echo sequences in MRI of the cervical spinal cord anatomy.

The aim of this study was to assess the detectability and distinguishability of the cervical spinal cord, the anterior and posterior spinal roots and of the internal anatomy of the cord (distinction of grey and white matter). For this purpose 20 healthy volunteers were examined using a 1.5 T MR unit with 20 mT/m gradient strength and a dedicated circular polarized neck array coil. Three T2* weighted (w). 2D gradient echo sequences, two T2 w. 2D turbo spin echo (TSE) sequences and one T2 w. 2D turbo gradient spin echo (TGSE) sequence were compared. The multiecho 2D fast low angle shot (FLASH) sequence with magnetization transfer saturation pulse (me FLASH+MTS) yielded the best results for liquor/compact bone, liquor/spinal cord and grey/white matter contrast, as found with regions of interest (ROI) analysis. The single echo 2D FLASH sequence was significantly poorer than the two me FLASH+/-MTS sequences. Two-dimensional TGSE as well as 2D TSE with a 256 matrix and with a 512 matrix yielded the poorest results. In the visual analysis the contrast between liquor and compact bone, liquor and cord as well as liquor and roots was best with me FLASH+MTS, whereas grey/white matter distinction was best using me FLASH-MTS. In conclusion, we would therefore recommend the inclusion of an axial T2* w. multiecho 2D spoiled gradient echo sequence with magnetization transfer saturation pulse and gradient motion rephasing in a MR imaging protocol of the cervical spine.

Adult↗

Frequency of benign hepatic lesions incidentally detected with contrast-enhanced thin-section portal venous phase spiral CT.

PURPOSE: To evaluate the frequency of benign focal hepatic lesions incidentally detected at contrast-enhanced thin-section portal venous phase spiral CT. MATERIAL AND METHODS: Between January 1998 and February 1999, contrast-enhanced hepatic spiral CT examinations were performed in 1,892 patients. Out of these, only 100 patients fulfilled the following inclusion criteria: No underlying malignant disease, no liver cirrhosis, no suspected or known focal liver lesions. Standardized spiral CT parameters were applied. All CT studies were reviewed retrospectively by one radiologist. Any focal lesion was recorded and classified. Lesion size and number were noted. RESULTS: A total of 108 hepatic lesions were reported in 33 out of 100 patients (80 cysts; 18 hemangiomas; 3 focal fatty infiltrations; 2 focal non-tumorous perfusion defects; 1 calcification; and 4 non-classified lesions). The average lesion size was 9.4 mm (< or =5 mm: n=40; 6-10 mm: n=30; 11-15 mm: n=28; >15 mm: n=10). CONCLUSION: Benign liver lesions are probably a frequent incidental finding at abdominal spiral CT.

Adult↗

Quantification of blood flow in the carotid arteries: comparison of Doppler ultrasound and three different phase-contrast magnetic resonance imaging sequences.

RATIONALE AND OBJECTIVES: To compare blood flow velocities in the carotid arteries measured with three different magnetic resonance (MR) phase-contrast imaging techniques and with percutaneous Doppler ultrasound. METHODS: Fourteen healthy male volunteers with a mean age of 33 +/- 3.8 years were studied. Ultrasound and MR phase velocity mapping of both common carotid arteries (n = 28) was performed within 5 hours. A two-dimensional fast low-angle shot sequence with retrospective cardiac gating, a sequence with prospective cardiac triggering, and a breath-hold sequence with prospective cardiac triggering were used. Resistance indexes and pulsatility indexes were calculated for all modalities. RESULTS: The comparison of flow velocities obtained with ultrasound and the different MR techniques led to a moderate correlation of the retrospective gated and prospective triggered MR techniques (eg, r = 0.73 for maximum systolic velocity). The worst correlation was found between the breath-hold technique and retrospective cardiac gating (eg, r = 0.004 for pulsatility index). There was a weak correlation of all three MR sequences compared with ultrasound (r = 0.19-0.60) CONCLUSIONS: A moderate correlation was found between velocities and indexes measured with the prospective cardiac-triggered phase-contrast MR technique and the retrospective cardiac-gated phase-contrast MR technique. A weak correlation was found between the three different MR techniques and ultrasound, as well as between the breath-hold prospective cardiac-triggered MR sequence and both of the other MR sequences. The influence of temporal and spatial resolution on MR phase-contrast velocity mapping was confirmed.

Adult↗

Comparison between magnetic resonance phase contrast imaging and transcranial Doppler ultrasound with regard to blood flow velocity in intracranial arteries: work in progress.

OBJECTIVE: The authors evaluate blood flow velocities in the medial cerebral artery (MCA) and the basilar artery using magnetic resonance (MR) phase contrast technique in comparison with transcranial Doppler ultrasound (TCD). Eleven healthy male volunteers were studied. TCD of the MCA (n = 22) and basilar artery (n = 11) was performed. MR phase velocity mapping was done in each vessel at the same location where the TCD signal had been acquired. A 2-dimensional FLASH sequence with retrospective cardiac gating and an average temporal resolution of 45 ms was used. Resistance indices (RIs) and pulsatility indices (PIs) were calculated for both modalities. The TCD insonation angle was measured retrospectively with MR, and TCD velocities were corrected based on these measurements. The comparison of flow velocities obtained with TCD and MR led to a low correlation coefficient with regard to the basilar artery and the MCA: maximum systolic velocity, r = 0.02 and r = 0.50, respectively; enddiastolic velocity, r = 0.47 and r = 0.65, respectively; mean velocity, r = 0.52 and r = 0.66, respectively. The average PIs in the basilar artery and the MCA were 0.80 and 0.81 with MR and 0.65 and 0.85 with TCD, respectively. The average RIs in the basilar artery and the MCA were 0.52 and 0.54 with MR and 0.52 and 0.55 with TCD, respectively. The TCD insonation angle differed significantly from the ideal value in the basilar artery (mean value = 32.6 degrees) and the MCA (mean value = 26.5 degrees). The authors find a low correlation between velocities measured with MRI and TCD but similar results with regard to the PIs and RIs. Several sources of error, such as a nonideal TCD insonation angle, were identified.

Adult↗

Visualization of the IXth to XIIth cranial nerves using 3-dimensional constructive interference in steady state, 3-dimensional magnetization-prepared rapid gradient echo and T2-weighted 2-dimensional turbo spin echo magnetic resonance imaging sequences.

OBJECTIVE: The purpose of this study was to evaluate the visibility of the IXth to XIIth cranial nerves using different magnetic resonance sequences. Thirty healthy volunteers underwent magnetic resonance imaging at 1.5 T using 3-dimensional constructive interference in steady state (CISS) sequence (TR = 17 ms, TE = 8.08 ms, alpha = 70 degrees), 3-dimensional magnetization-prepared rapid gradient echo (MP-RAGE) sequence (TR = 11.08 ms, TE = 4.3 ms, alpha = 15 degrees), and T2-weighted (w) 2-dimensional turbo spin echo (TSE) sequence (TR = 4000 ms, TE = 102 ms, alpha = 180 degrees, slice thickness = 2 mm). Visibility of the IXth to XIIth cranial nerves in each sequence was evaluated by consensus of 2 radiologists using an evaluation scale from 1 (excellently visible) to 5 (not visible). A correlation with anatomic specimens was made. The 3-dimensional CISS sequence provides best resolution of the IXth to XIIth cranial nerves and their relation to surrounding structures. Additional information is given by the 3-dimensional MP-RAGE when nerves are surrounded by soft tissues. Using the T2w 2-dimensional TSE sequence, even whole nerves cannot be visualized due to intersection gap and partial volume effects. However, even in 3-dimensional high-resolution sequences, segments of nerves are not always visualized. A combination of 3-dimensional CISS and 3-dimensional MP-RAGE proved to be useful to visualize the IXth to XIIth cranial nerves, whereas the 2-dimensional technique failed. Further investigations using 3-dimensional MP-RAGE with contrast medium should be performed in the case of abnormality.

Accessory Nerve↗

Renal time-resolved MR angiography: quantitative comparison of gadobenate dimeglumine and gadopentetate dimeglumine with different doses.

PURPOSE: Results with different doses of gadobenate dimeglumine and gadopentetate dimeglumine were compared at magnetic resonance (MR) angiography of the renal arteries. The signal-to-noise ratio (SNR) was evaluated as a quantitative measure of image quality. MATERIALS AND METHODS: Sixty consecutive patients (age range, 24-81 years; mean age, 65 years) underwent intraarterial digital subtraction angiography (DSA) and contrast material-enhanced time-resolved MR angiography. DSA was the standard of reference. Fifteen patients received gadopentetate dimeglumine at doses of 0.2 or 0.1 mmol per kilogram of body weight. Fifteen patients received gadobenate dimeglumine at doses of 0.05 or 0.1 mmol/kg. The SNR was calculated in the aorta and both main renal arteries. The number and degree of stenoses of the renal arteries and accessory vessels were evaluated by four observers. RESULTS: SNRs with gadobenate dimeglumine at a dose of 0.1 mmol/kg were significantly superior to those with gadopentetate dimeglumine at a dose of 0.1 mmol/kg. Differences were not statistically significant between the SNRs in the other groups. Eleven (85%) of 13 hemodynamically significant renal artery stenoses were detected correctly with MR angiography as were 22 (85%) of 26 accessory renal arteries. CONCLUSION: SNRs with gadobenate dimeglumine were higher than those with gadopentetate dimeglumine, but in most cases the differences in SNRs were not statistically significant.

Adult↗

Purification and characterization of macrophage migration inhibitory factor as a secretory protein from rat epididymis: evidences for alternative release and transfer to spermatozoa.

BACKGROUND: The cytokine macrophage migration inhibitory factor (MIF), originally described as a T cell product, has recently been identified to mediate cellular interactions in several endocrine organs. Western blots analysis of rat epididymal homogenates using an anti-MIF antibody indicated the presence of substantial amounts of an immunoreactive protein with the apparent Mr of 12 kDa. Our study aimed to characterize the molecular nature of this immunoreactive factor. MATERIALS AND METHODS: The purified 12 kDa protein and a cloned cDNA fragment were characterized by sequence analysis. Furthermore, expression pattern and localization of the 12 kDa protein were investigated using in situ hybridization, immunohistochemistry, immunoelectron microscopy, and western blots experiments on epididymal sections, isolated epididymal vesicles, and outer dense fibers from spermatozoa. RESULTS: The N-terminal amino acid sequence analysis over 10 amino acids revealed a 100% homology of the 12 kDa protein to the N-terminus of the cytokine MIF. These data were confirmed by sequence analysis of a reverse transcription polymerase chain reaction (RT-PCR) amplified cDNA fragment from rat epididymis, which also showed complete homology to the MIF cDNA sequence. MIF protein and mRNA were localized in the epithelial cells of the epididymis in a regional distribution manner, with the expression maximal in the caput. Immune cells were not labeled. MIF is the first classical cytokine identified to be expressed by the epididymal epithelial cells. Immunoelectron microscopy detected MIF immunoreactivity in the cytoplasm, with no reaction visible in the Golgi complex and the cisternae of the endoplasmic reticulum. At the apical cell surface, MIF accumulated in stereocilia and vesicles that were pinched off from the plasma membrane. MIF detection in vesicles isolated from epididymal secretion together with the lack of a N-terminal signal sequence for translocation in the endoplasmic reticulum strongly suggested a nonclassical secretion mode. Furthermore, MIF was identified as a new component of the outer dense fibers (ODF), a cytoskeletal element of the mid- and principal piece of the sperm tail. CONCLUSION: The cytokine MIF was identified in substantial amounts in the epithelial cells of rat epididymis and in the outer dense fibers of rat epididymal spermatozoa. Our results indicate a nonclassical secretion mode for MIF and suggest a cell-to-cell transfer of MIF via vesicles to the sperm cells.

Animals↗

Value of high-resolution MR in patients scheduled for cochlear implantation.

OBJECTIVE: To determine sensitivity and specificity of high-resolution MR imaging and of high-resolution axial CT (HRCT) and to compare the two modalities in predicting the surgical and functional success of cochlear implantation. MATERIAL AND METHODS: The presurgical MR images (2D T2W TSE, 3D T2*W CISS, plain and contrast-enhanced 3D T1W MP-RAGE) and axial HRCT findings of 26 patients were evaluated with regard to the predictive value concerning the success of cochlear implantation. RESULTS: We found a high correlation between MR and HRCT and the success of cochlear implantation. In all 26 patients, the MR-based predictions concerning the success of cochlear implantation were correct. In 10 patients, MR gave additional information to HRCT. In all patients, MR gave sufficient information about the status of the inner ear, inner auditory canal and cochlear nerve to aid the surgeon during the operation. CONCLUSION: A high-resolution MR protocol consisting of coronal 2D T2W TSE, 3D T2*W axial CISS, plain and contrast-enhanced sagittal T1W 3D MP-RAGE is recommended for the evaluation of candidates scheduled for cochlear implantation. It provides information which cannot be obtained by HRCT.

Adolescent↗

Activin maintains the condensed type of mitochondria in germ cells.

Development of germ cells during spermatogenesis is characterized by a complex series of differentiation events finally leading to the production of spermatozoa. Beside the main hormonal regulators, paracrine interactions are thought to play a major role in this process. Mitochondria in germ cells pass through unique alterations ranging from the 'typical' cristae-rich mitochondria found in spermatogonia to the 'condensed' form in pachytene spermatocytes. This study provides further support that paracrine factors produced by Sertoli cells, most likely activin A, are involved in germ cell differentiation as monitored by the maintenance of the physiological 'condensed' mitochondrial phenotype in primary spermatocytes. Culture of primary spermatocytes in Sertoli cell conditioned medium (SCCM) for 18 h resulted in the maintenance of a high percentage of 'condensed-type' mitochondria in comparison to cells cultured in Dulbecco's minimum essential medium (DMEM). Activin A, a product of Sertoli cells, showed at subnanogram concentrations a similar ability to SCCM to maintain a high percentage of spermatocyte mitochondria in the 'condensed' state, while inhibin had no effect. The addition of an antiserum specific for activin A resulted in a neutralization of the effect caused by activin A or SCCM. This strongly suggested that the active substance in SCCM was activin A. Taken together these data indicate that activin A is the first Sertoli cell product that has been identified to influence differentiation of male meiotic germ cells.

Activins↗

[3D CISS, 3D MP-PAGE and 2D TSE for the preoperative MRI prior to cochlear implantation].

PURPOSE: The aim of this study was to determine the presurgical predictive value of high resolution MRI in patients scheduled for cochlear implantation. METHOD AND MATERIAL: The presurgical MRI (3D CISS, 3D MP-RAGE with and without i.v. contrast medium, 2D TSE) findings of 54 patients and the intraoperative situation reported by the surgeon were compared retrospectively. The surgical and functional success of the cochlear implantation was evaluated. RESULTS: We found a high degree of correlation between MRI and intraoperative findings concerning the patency of the whole cochlea and anomalies as well as in the diagnosis of pathology of the cochlear, vestibular and facial nerves and in anomalies of the internal auditory canal. However, in four out of 54 patients there was a false negative prediction regarding the patency of the cochlea. The sensitivity was 50% (4/8), the specificity 100% (46/46). Concerning the surgical success the accuracy was 100%. In all patients MRI gave sufficient anatomical information to the surgeon concerning the jugular bulb and the facial nerve. CONCLUSION: A high-resolution MRI protocol consisting of coronal 2D T2w TSE, 3D T2*w transverse CISS; plain and contrast enhanced sagittal T1w 3D MP-RAGE is recommended for the evaluation of candidates scheduled for cochlear implantation.

Adolescent↗