PubMed Health⌕ Search

Biomedical subjects

J T Boys

Publications and source records attributed to J T Boys.

5 recordsLinked to original sources

Evaluation of potential health effects of 10 kHz magnetic fields: a rodent reproductive study.

New technology involving the use of high-frequency inductive power distribution (HID) has recently been developed for use in materials handling and personnel transfer. Sinusoidal magnetic fields at a frequency of 10 kHz with field intensities of approximately 0.2 mT are generated directly between the current-carrying coils of this equipment. Effects of 10 kHz magnetic fields on cell division, migration, and differentiation have never been previously investigated. To evaluate potential effects on these parameters, a rodent reproductive study was undertaken using Wistar rats. Exposures were at 0.095, 0.24, and 0.95 mT with a background exposure of 5-10 microT. Three sets of parental rats were exposed continuously for 20-23.5 h/day to the fields: maternal rats during gestation, paternal rats for at least 45 days prior to mating and maternal rats 1 month prior to mating. Exposure phases thus covered spermatogenesis, maturation of the ovum and ovulation, fertilization, implantation, embryogenesis, organogenesis, and maturation of the fetus immediately prior to parturition. In all experiments pregnancy outcome was assessed. These studies failed to demonstrate any reproductive toxicity resulting from maternal or fetal exposure during gestation or following paternal or maternal exposure for several weeks prior to mating. No quantitative or qualitative effects on spermatogenesis occurred after exposure, and no effects on the estrous cycle or ovulation could be demonstrably linked to the 10 kHz magnetic field exposure at 0.095, 0.25, or 0.95 mT. Where possible, parental clinical chemistry and hematology were also examined. As in mouse toxicology studies previously reported, minor differences were observed between control and treated groups. These were regarded as statistically, but not biologically, significant and could not categorically be attributed to magnetic field exposure.

Animals↗

Evaluation of potential health effects of 10 kHz magnetic fields: a short-term mouse toxicology study.

A high-frequency inductive power distribution (HID) technology has been developed that generates sinusoidal magnetic fields at a frequency of 10 kHz. In typical industrial applications, field intensities in the order of 0.2 mT can be expected between the current-carrying coils. Because the possible health effects of 10 kHz sinusoidal magnetic fields of this type had never been investigated, a broad evaluation of possible effects on animal health was made in a preliminary 14 day acute study and in a 90 day subchronic study using male and female B6C3F1 mice. Exposures were at 0.08, 0.28, and 1.0 mT vs. a background exposure of 3.7 microT and were essentially continuous. These studies failed to demonstrate any health effects that can be clearly related to the magnetic field exposure. No changes in animal behaviour or indications of morbidity were detected during the initial exposure to the fields. There were no significant differences in body weight between exposed and unexposed (control) mice at any time in the study, and the clinical chemistry and hematology parameters were essentially unchanged. Although minor differences in some clinical chemistry and hematology parameters were seen between control and exposure groups, the lack of exposure dependence, the lack of consistency between sexes, and the lack of correspondence with the results of the two studies all suggest that these were chance associations. Even if the changes were real, the magnitude of the changes was very small and does not indicate serious biological effects. Finally, all organs were macroscopically and microscopically normal except for isolated, generally mild, histological lesions and lesions that were ascribed to fighting among males. There was no obvious association with field intensity.

Animals↗

A prosthetic aid for a developing blind child.

An experimental ultrasonic sonar for use as a sensory aid with blind children is described. Novel signal processing techniques make the aid relatively simple to construct, yet allow many of its parameters to be changed in the field. In particular, the aid has two features, a variable range code and an automatic level control, which make the device very versatile in a wide variety of environments. The ultrasonic tranducers used in the aid are described in some detail.

Blindness↗

Improved continuous wave frequency modulated sonars with aural displays.

This paper discusses methods for reducing the effects of the reset hiatus and wavelength related variations in received signal strength on the aural displays produced by simple continuous wave frequency modulated sonars. Two techniques that have been developed for reducing the effects of signal phase and amplitude discontinuities are described. As a practical example of the improved performance afforded by one of these techniques, a novel short range sonar for examining cardiovascular structures is discussed in detail.

Electrocardiography↗