PubMed Health⌕ Search

PubMed · 644683

Improved continuous wave frequency modulated sonars with aural displays.

Abstract

This paper discusses methods for reducing the effects of the reset hiatus and wavelength related variations in received signal strength on the aural displays produced by simple continuous wave frequency modulated sonars. Two techniques that have been developed for reducing the effects of signal phase and amplitude discontinuities are described. As a practical example of the improved performance afforded by one of these techniques, a novel short range sonar for examining cardiovascular structures is discussed in detail.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J T Boys, J L Mason, R M Hodgson. 1978. Improved continuous wave frequency modulated sonars with aural displays.. https://doi.org/10.1016/0041-624x(78)90038-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations