PubMed Health⌕ Search

Biomedical subjects

J Tobis

Publications and source records attributed to J Tobis.

At least 19 recordsLinked to original sources

Discrepancy between angiography and intravascular ultrasound when analysing small coronary arteries.

AIMS: A small reference diameter may be the consequence of high plaque burden and diffuse disease. The reference vessel diameter in small coronary arteries may vary according to the method of measurement used. We endeavoured to confirm the difference between data from examinations conducted using angiography with that revealed by intravascular ultrasound. METHODS AND RESULTS: Between March 1993 and October 1999, 344 consecutive patients with 419 lesions in small vessels (< or =2.75 mm, Small group) and 953 patients with 1161 lesions in large vessels (Large group) underwent intravascular ultrasound-guided percutaneous transluminal angioplasty in our Institution. The mean difference between the intravascular ultrasound and the angiographic reference diameter (Delta(IVUS-Angio)) was 1.3+/-0.5 mm in the Small group and 1.0+/-0.6 mm in the Large group (P<0.001). There was a stronger correlation between plaque burden and Delta(IVUS-Angio)in the Small group (r=0.80, P<0.001) than in the Large group (r=0.59, P<0.001). An Delta(IVUS-Angio)> or =0.30 mm occurred in 99.5% of cases in the Small group and in 90% in the Large group (P<0.001). An Delta(IVUS-Angio)> or =0.50 mm occurred in 96% of case in the Small group and 80% in the Large group (P<0.001). Predictors of Delta(IVUS-Angio)> or =0.50 in the Small group were: proximal or middle lesion site, vessel type (left anterior descending artery, diagonal and obtuse marginal branches) and female sex. An Delta(IVUS-Angio)> or =1.0 mm occurred in 71% of cases in the Small group and in 49% in the Large group (P<0.001). Predictors of Delta(IVUS-Angio)> or =1.0 mm in the Small group were: proximal or middle lesion site, female sex, and lesion length. CONCLUSIONS: A high percentage of vessels measuring < or =2.75 mm are large vessels with a high plaque burden. This condition is particularly prevalent in females, with lesions in the proximal or middle left anterior descending artery, and in obtuse marginal and diagonal branches.

Aged↗

Longitudinal study of vascular remodeling in coronary arteries after heart transplantation.

Cross-sectional studies by intravascular ultrasound (IVUS) in heart transplant recipients have suggested that vascular remodeling occurs in coronary arteries years after transplant. However, no reports describe vascular remodeling in the same cohort of patients studied prospectively using morphometric analysis (10 evenly spaced images obtained from a slow pullback from the left anterior descending coronary artery). Morphometric analysis better reflects total vessel anatomy compared with previously reported site (2 to 3 images) analysis. We reviewed 20 patients studied by IVUS at 2 months, 1 year, 2 years, and 3 years after heart transplant.Over time, the coronary artery luminal area decreased from baseline level of 12.0 mm(2) to a 3-year mark of 9.7 mm(2) (p = 0.02). Vessel shrinkage was seen in 16/20 patients. After an initial rise in intimal parameters (maximal intimal thickness, intimal index, and plaque area) from baseline to 1 year, we found a significant decrease in intimal parameters between Year 1 and Year 3 after transplant. For example, plaque area decreased from 2.05 mm(2) at 1 year post-transplant to 1.48 mm(2) by 3 years post-transplant (p = 0.05). In a majority of heart transplant patients, early intimal thickening in the first year post-transplant is accompanied by constrictive remodeling. Over the subsequent 2 years, further constrictive remodeling is seen despite a decrease in intimal area.

Adult↗

Calcified plaque cross-sectional area in human arteries: correlation between intravascular ultrasound and undecalcified histology.

BACKGROUND: The purpose of this investigation was to quantify the amount of intralesional calcium detected by intravascular ultrasound (IVUS) compared with undecalcified histology in human arteries. This method preserves intralesional calcium and reduces sectioning artifacts, thereby providing an accurate measure of calcium plaque morphology. METHODS AND RESULTS: Ten arterial segments (5 coronary, 5 iliac) were obtained at autopsy. IVUS imaging was performed with a 4.9F catheter at an automated pullback rate of 1.0 mm/s. The undecalcified arteries were dehydrated in ascending alcohol and polymerized in glycol methylmethacrylate. The arteries were cut into 200-microm sections with an Isomet low-speed saw and stained with Goldner's trichrome. The lumen cross-sectional area, the calcium plaque cross-sectional area, the calcium plaque depth, length, and angle of arc of calcified plaque were measured from the IVUS images and histologic sections. In 24 selected cross sections, there were 38 separate calcium plaques. An independent observer correctly identified 34 of 38 calcified plaques for a sensitivity of 89% and specificity of 97%. The total mean calcified plaque cross-sectional area measured from histology was 4.6 +/- 4.1 mm2 compared with 2.8 +/- 2.3 mm2 by IVUS (P =.002). Plaque depth measured by histology was 1.2 +/- 0.4 mm versus 0.7 +/- 0.2 mm by IVUS (P =.001). The length of calcium plaques measured by histology was 3.6 +/- 1.78 mm versus 3.6 +/- 1.5 mm for IVUS (r = 0.79). CONCLUSIONS: IVUS accurately depicts circumferential calcified lesions with high sensitivity (89%) and specificity (97%). However, IVUS underestimates the total calcified plaque cross-sectional area by 39%. This is mainly because of the inability of the ultrasound to penetrate intralesional calcium, which leads to an underestimation of the depth of calcium by 45%.

Adult↗

Video networking of cardiac catheterization laboratories.

BACKGROUND: The purpose of this study was to assess the feasibility and accuracy of a video telecommunication network to transmit coronary images to provide on-line interaction between personnel in a cardiac catheterization laboratory and a remote core laboratory. METHODS: A telecommunication system was installed in the cardiac catheterization laboratory at Kaiser Hospital, Los Angeles, and the core laboratory at the University of California, Irvine, approximately 40 miles away. Cineangiograms, live fluoroscopy, intravascular ultrasound studies and images of the catheterization laboratory were transmitted in real time over a dedicated T1 line at 768 kilobytes/second at 15 frames/second. These cases were performed during a clinical study of angiographic guidance versus intravascular ultrasound (IVUS) guidance of stent deployment. During the cases the core laboratory performed quantitative analysis of the angiograms and ultrasound images. Selected images were then annotated and transmitted back to the catheterization laboratory to facilitate discussion during the procedure. RESULTS: A successful communication hookup was obtained in 39 (98%) of 40 cases. Measurements of angiographic parameters were very close between the original cinefilm and the transmitted images. Quantitative analysis of the ultrasound images showed no significant difference in any of the diameter or cross-sectional area measurements between the original ultrasound tape and the transmitted images. The telecommunication link during the interventional procedures had a significant impact in 23 (58%) of 40 cases affecting the area to be treated, the size of the inflation balloon, recognition of stent underdeployment, or the existence of disease in other areas that was not noted on the original studies. CONCLUSIONS: Current video telecommunication systems provide high-quality images on-line with accurate representation of cineangiograms and intravascular ultrasound images. This system had a significant impact on 58% of the cases in this small clinical trial. Telecommunication networks between hospitals and a central core laboratory may facilitate physician training and improve technical skills and judgement during interventional procedures. This project has implications for how multicenter clinical trials could be operated through telecommunication networks to ensure conformity with the protocol.

Angioplasty, Balloon, Coronary↗

Coronary stenting after rotational atherectomy in calcified and complex lesions. Angiographic and clinical follow-up results.

BACKGROUND: Treatment of calcified (in contrast to simple) lesions with PTCA has been associated with a lower success rate and more procedural complications. Rotablation can improve acute results, but the high restenosis rate remains a problem. The purpose of this study was to evaluate the clinical and angiographic outcome of patients with complex and calcified lesions treated with a combination of rotablation and stenting. METHODS AND RESULTS: Seventy-five consecutive patients with 106 lesions had rotablation prior to coronary stenting. Intravascular ultrasound-guided stenting was used without subsequent anticoagulation in 93% of patients. Procedural success was achieved in 93.4% of lesions. Acute stent thrombosis occurred in two lesions (1.9%), and subacute stent thrombosis in one lesion (0.9%). Angiographic follow-up was performed in 82.5% of lesions at 4.6 +/- 1.9 months with an angiographic restenosis rate of 22.5%. Clinical follow-up was performed in all patients at 6.4 +/- 3 months; target lesion revascularization was needed in 18% of lesions; Q-wave myocardial infarction occurred in 1.3%, coronary bypass surgery in 4.0%, and death in 1.3%. CONCLUSIONS: Optimal coronary stenting after rotablation in calcified and complex lesions can be performed with a high success rate, an acceptable rate of procedural complications, and a low rate of stent thrombosis. This approach was associated with a low incidence of angiographic restenosis compared with results usually obtained with other interventional strategies in calcified and complex lesion subsets.

Aged↗

Video networking of cardiac catheterization laboratories.

UNLABELLED: A video telecommunication network was established to transmit coronary images between a cardiac catheterization laboratory and a remote core laboratory. In 40 patients during interventional procedures, cine angiograms, live fluoroscopy, intravascular ultrasound studies, and images of the cath lab were transmitted in real time over a T1 line at 768 kbits/second at 15 frames/second. RESULTS: Measurements of angiographic and intravascular ultrasound parameters were very close between the original studies and the transmitted images. The telecommunication link up during the interventional procedures had a significant affect in 58% of cases.

Cardiac Catheterization↗

Subacute stent thrombosis in the era of intravascular ultrasound-guided coronary stenting without anticoagulation: frequency, predictors and clinical outcome.

OBJECTIVES: This study was performed to determine predictors of subacute stent thrombosis (SST) in the era of intravascular ultrasound (IVUS)-guided coronary stenting without anticoagulation. BACKGROUND: The incidence of stent thrombosis has declined with the application of high pressure stent deployment with only antiplatelet therapy. However, no data are available on predictors of stent thrombosis in this era. METHODS: Between March 30, 1993 and July 31, 1995, 1,042 consecutive patients underwent coronary stenting without anticoagulation. For this analysis, we excluded patients who underwent coronary artery bypass surgery, died or had acute stent thrombosis within the 1st 24 h after stenting (41 patients). A total of 1,001 patients (1,334 lesions) were included; 982 patients (1,315 lesions) without SST and 19 patients (19 lesions) with SST. RESULTS: The rate of SST was 1.9% (per patient). There was no difference between the SST and No SST groups in rescue stenting (12% vs. 13.5%, p = 1.0) or mean +/- SD reference diameter (3.11 +/- 0.58 vs. 3.19 +/- 0.53 mm, p = 0.54). A preexisting thrombus was present in 12% of the SST group and in 4.5% of the No SST group (p = 0.19). Predictors of SST by univariate analysis were low ejection fraction (p = 0.004), more stents per lesion (p = 0.049), use of combination of different stents (p = 0.012), smaller balloon size (p = 0.012) and suboptimal result in terms of smaller lumen dimensions by angiography (p = 0.016) and IVUS (p = 0.004), residual dissections (p = 0.027) and slow flow (p = 0.0001). In stepwise logistic regression analysis, ejection fraction (p = 0.019), use of a combination of different stents (p = 0.013) and postprocedure dissections (p = 0.014) and slow flow (p = 0.0001) were predictive of SST. CONCLUSIONS: In the present era of stent implantation, factors that may predispose to SST are low ejection fraction, intraprocedural complications leading to utilization of more stents, particularly with different stent designs, and suboptimal final result in terms of smaller lumen dimensions and persistent slow flow and dissections.

Anticoagulants↗

First experience with imaging core wires.

This study is the first assessment of feasibility and clinical usefulness of an imaging wire. The device used is a 0.018" flexible cable mounting a 30 MHz piezoelectric crystal at the end. The only possible application of the wire in its current configuration is the assessment of balloon expansion with over-the-wire balloon catheters. In this study, 17 lesions were examined in 14 patients. Despite careful removal of the air, no image could be obtained with the balloon deflated or through the shaft of conventional balloon catheters. When the balloon was inflated to 1-4 atm the circular echo-free cross-section of the balloon became visible, surrounded by the dense line of the balloon membrane and by the vessel wall. By examining the stent area at different balloon pressures, it was possible to determine the stent recoil between maximal balloon expansion and lowest balloon pressure allowing a readable ultrasound image. These encouraging preliminary observations confirm the feasibility of the use of an ultrasound guidewire for monitoring balloon expansion during stent implantation. After high pressure inflation, a moderate reduction of the stent lumen was observed during deflation, compatible with the small recoil predicted for the stainless-steel mesh stent used.

Angioplasty, Balloon, Coronary↗

Identification of coronary thrombus after myocardial infarction by intracoronary ultrasound compared with histology of tissues sampled by atherectomy.

This study compares the ability of intracoronary ultrasound (ICUS) to identify thrombus by means of actual criteria, with the histologic studies of tissues removed by directional atherectomy in patients treated previously with thrombolytic therapy. Coronary angiography and intravascular ultrasound imaging were performed before atherectomy in 34 patients who had received intravenous thrombolytic therapy for acute myocardial infarction a mean of 6 days before. The lesion morphology and the percentage of stenosis were defined on the angiogram. The ultrasound characteristics of the narrowing were described as intraluminal thrombus, mural thrombus, mixed plaque, and dense plaque. Thirty patients were studied. Thrombus was suspected in 8 patients on angiography. By ICUS, the presence of thrombus was predicted in 21 patients. Histologic studies of excised tissues found thrombus in 20 of the 30 patients. When ICUS was compared with histology, the true-positive rate was 80% and the false-positive rate was 50%; the true-negative rate was 50% and the false-negative rate was 20%. The correlation between observers was high. These observations suggest that ICUS may be useful in identifying fresh thrombus. The findings of this study help to confirm the criteria for diagnosing intraluminal thrombus by ICUS imaging.

Adult↗

Unrecognized stenosis by angiography documented by intravascular ultrasound imaging.

This report documents how intravascular ultrasound imaging was used to diagnose a short "napkin-ring" stenosis that was missed by coronary angiography. Intravascular ultrasound revealed a lumen of 2.6 x 2.5 mm in diameter and 5.0 mm2 in cross-sectional area, with a residual atheroma that occluded 63% of available cross-sectional area at the stenosis.

Angiography↗

Laser-assisted thermal angioplasty in human peripheral artery occlusions: mechanism of recanalization.

Recanalization of completely occluded superficial femoral or popliteal arteries was attempted in 18 patients with use of an Argon laser-mediated thermal probe. The length of the occluded segments varied between 0.5 and 26.0 cm, but 67% of the occlusions were greater than 9 cm long. The initial success rate was 67%. Arterial perforation occurred in six patients but was not associated with major complications. To study the mechanism of the laser-mediated thermal probe, thermal recanalization was performed on 11 human arterial segments in vitro obtained after amputation, and mechanical recanalization was performed in vitro in 10 human peripheral arteries with use of a guide wire and catheter technique. An additional four arteries were studied with the laser probe as a non-heated mechanical device. Both the mechanical and thermal devices appear to follow a similar pathway through a complete obstruction. These studies suggest that the thermal probe burns through soft fibrous tissue but is mechanically deflected away from hard fibrocalcific plaque. The probe then advances along the plane between the intimal plaque and the media for a variable length before perforating through the adventitia. These observations suggest that the major mechanism of thermal probe recanalization may be a mechanical process. It appears that thermal probe devices do not inherently seek the true lumen of an occluded artery and that better guidance systems need to be developed.

Aged↗

Correlation of minimum coronary lumen diameter with left ventricular functional impairment induced by atrial pacing.

To understand whether quantitative measurement of minimal coronary luminal diameter is a better method than percent diameter narrowing for assessing the functional impairment of myocardial contractility produced by coronary artery stenoses, measurements were made from 37 stenotic segments in 27 patients with coronary artery disease and from corresponding segments in 10 subjects without coronary artery narrowing. An assessment of the reliability of the 2 types of measurements was made by correlating them with the physiologic parameters of both segmental wall motion and global ejection fraction response induced by atrial pacing. Digitally acquired coronary angiograms were used to facilitate quantitative analysis. Measurements by edge detection and videodensitometry correlated closely (r = 0.94). Percent diameter narrowing correlated moderately with the change in ejection fraction (r = -0.41) or with the change in segmental wall motion (r = -0.44). The measurement of minimal lumen diameter correlated with the change in global ejection fraction (r = 0.61) and did so even better with the change in segmental wall motion (r = 0.78, p less than 0.05). A minimal lumen diameter of less than or equal to 1.5 mm identified patients likely to have a functional impairment during atrial pacing as assessed by either global ejection fraction or segmental wall motion defects. We conclude that minimal coronary luminal diameter provides a better method than percent diameter narrowing calculations to measure the anatomic severity of coronary artery narrowing.

Angiography↗

Videodensitometric determination of minimum coronary artery luminal diameter before and after angioplasty.

Quantitative measurements of coronary stenoses were made from digital coronary angiograms in 19 patients before and after percutaneous transluminal coronary angioplasty (PTCA). Two methods of measurement were compared. Mean stenosis before PTCA was 67 +/- 10% by the edge detection method and 67 +/- 12% by videodensitometry (difference not significant). After PTCA, the mean stenosis was 32 +/- 14% by edge detection and 30 +/- 13% by videodensitometry (difference not significant). In addition, a new method was developed to rapidly calculate the absolute minimum luminal area and diameter by videodensitometry. The minimum luminal diameter before PTCA was 1.0 +/- 0.5 mm and after PTCA increased to 2.4 +/- 0.5 mm (p less than 0.001). The validity of the videodensitometric method was analyzed in a series of Lucite phantom studies, which suggested that when there is an irregular angiographic appearance, the densitometric method may be more accurate than standard edge detection methods. Digital acquisition of coronary angiograms provides a means for rapid application of quantitative analysis during coronary interventional procedures.

Angioplasty, Balloon↗

Beta-endorphin/beta-lipotropin release and gonadotropin secretion after acute exercise in normal males.

The plasma beta-endorphin (beta-EP) and beta-lipotropin (beta-LPH) response to acute exercise and the relationship of these opioid peptides to basal and luteinizing hormone-releasing hormone (LRH)-stimulated luteinizing hormone (LH) and follicle-stimulating hormone (FSH) secretion was studied in eight normal male volunteers. Acute exercise resulted in a rise in plasma beta-LPH levels that returned to base line when measured 60 min after exercise. Plasma beta-EP levels did not demonstrate any rise when measured immediately after 20 min of exercise or at 60 min after exercise. Serum LH concentrations in individual volunteers declined to nadir values 60-180 min after exercise after which they showed a rebound to levels higher than the preexercise values in three of five volunteers in whom nadir LH levels were attained before the final (180 min) measurement. Serum FSH concentrations were unaltered by exercise. Acute exercise similarly did not alter the LH/FSH response to exogenous LRH stimulation. Pretreatment of the volunteers with the narcotic antagonist, naloxone, failed to alter the postexercise or LRH-stimulated LH and FSH release. The data suggest that beta-EP does not exert a suppressive effect on LH secretion after acute exercise in normal human males. Whether the suppression of LH secretion after acute exercise in unconditioned males is due to factor(s) cosecreted with beta-LPH, an increase in brain beta-EP or to alternate mechanisms such as alteration in central dopaminergic or GABAergic tone remains to be established.

Adult↗

Determination of the optimal timing for performing digital ventriculography during atrial pacing stress tests in coronary heart disease.

To determine the optimal time for recording left ventricular angiograms during atrial pacing stress tests, digital subtraction left ventriculograms were obtained using 12 ml of contrast material in 40 patients at rest and at peak pacing. Nineteen of the 40 patients had a third digital left ventriculogram performed between 5 and 10 seconds and 21 patients had a third digital left ventriculogram performed 30 seconds after pacing was stopped. Coronary angiography showed significant coronary artery disease (CAD) in 29 patients and no evidence of significant CAD in 11 patients. Ejection fraction (EF) increased or did not change at peak pacing in 10 of 11 patients without CAD. In the 29 patients with CAD, mean EF decreased an average of 10 percentage points (p less than 0.001) and fell 2 or more percentage points in 25 patients (86%) at peak pacing. These changes in EF were accompanied by the development of wall motion abnormalities, which occurred in segments of myocardium that were supplied by coronary arteries with angiographic CAD (more than 50% diameter narrowing). In contrast, the mean EF during the postpacing studies decreased only 2.2 percentage points (difference not significant) over rest values. Moreover, 15 of 29 patients (52%) with CAD had a decrease in EF of 2 or more percentage points. Therefore, the sensitivity of the atrial pacing stress test was diminished when the analysis was performed at 10 or 30 seconds after pacing. It is concluded that EF changes and wall motion abnormalities induced by atrial pacing are of short duration.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗