First experience with imaging core wires.

Abstract

This study is the first assessment of feasibility and clinical usefulness of an imaging wire. The device used is a 0.018" flexible cable mounting a 30 MHz piezoelectric crystal at the end. The only possible application of the wire in its current configuration is the assessment of balloon expansion with over-the-wire balloon catheters. In this study, 17 lesions were examined in 14 patients. Despite careful removal of the air, no image could be obtained with the balloon deflated or through the shaft of conventional balloon catheters. When the balloon was inflated to 1-4 atm the circular echo-free cross-section of the balloon became visible, surrounded by the dense line of the balloon membrane and by the vessel wall. By examining the stent area at different balloon pressures, it was possible to determine the stent recoil between maximal balloon expansion and lowest balloon pressure allowing a readable ultrasound image. These encouraging preliminary observations confirm the feasibility of the use of an ultrasound guidewire for monitoring balloon expansion during stent implantation. After high pressure inflation, a moderate reduction of the stent lumen was observed during deflation, compatible with the small recoil predicted for the stainless-steel mesh stent used.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Di Mario, T Akiyama, I Moussa, B Reimers, Y T Jang, J Tobis, A Colombo. 1997. First experience with imaging core wires.. https://pubmed.ncbi.nlm.nih.gov/9546987/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Stent fracture: an unusual cause of late restenosis after sirolimus-eluting stent placement.

Stent fracture is uncommon but may have consequences including restenosis. To date, stent fractures reported have been related to aggressive post dilation. We describe a case that involves fracture of a stent deployed to nominal pressure. Unlike most stent fractures reported that involve stent struts only our case demonstrated circumferential disruption with complete separation of the stent segments.

Angioplasty, Balloon, Coronary↗

Magnetic navigation system used successfully to cross a crushed stent in a bifurcation that failed with conventional wires.

Bifurcation lesions can be technically demanding to manage, and even in the era of drug eluting stents, their procedural success is variable. The use of the crush technique followed by "kissing" balloon postdilatation has been shown to improve the overall outcome. However, crossing the crushed stent is essential to allow performance of a final dilatation with "kissing" balloons and is regarded as the main Achilles' heel of this technique. In this report, we describe the first reported, planned procedure to use a magnetic navigation system to steer a wire through the crushed stent to use "kissing" balloons that had previously failed with conventional wires.

Angioplasty, Balloon, Coronary↗

On understanding the power of judgement in percutaneous coronary intervention.

AIM: Explain how research can advance the state-of the- practice in percutaneous coronary intervention (PCI). METHODS AND RESULTS: Identifying the success factors of PCI; identifying decision- making performance (power of judgement) as the factor that could be advanced faster than is currently the case; explaining why and how such advancement needs a different research approach than those currently pursued in medical research; presenting initial results of this approach in the form of a set of basic concepts (pivoting around risk) that are useful for describing the decision-making process during a PCI. CONCLUSION: Building a terminology (ontology) of PCI decision-making concepts and then eliciting expert knowledge about the decision-making process itself are promising ways of advancing the teachability of PCI and hence the state-of-the practice.

Angioplasty, Balloon, Coronary↗