PubMed Health⌕ Search

Biomedical subjects

J W Griffith

Publications and source records attributed to J W Griffith.

59 records · Page 4Linked to original sources

Evaluation of a second-generation tantalum biliary stent in a canine model.

PURPOSE: To evaluate the safety and feasibility of use of a balloon-expandable tantalum (Tantaflex) stent in the biliary tree in a canine model. MATERIALS AND METHODS: In this prospective, randomized trial, 10 tantalum stents were placed in eight dogs (two telescoping stents in two dogs), and six Wallstents were placed in six dogs as controls. Stents were deployed into the common bile duct via a cholecystostomy at laparotomy under fluoroscopic and cholangiographic guidance. Two dogs from each stent group were killed at 4, 12, and 26 weeks; the two dogs with telescoping stents were killed at 12 weeks. Premortem patency was confirmed cholangiographically. Postmortem stent explants were inspected grossly, and tissues were examined histologically. Bacteriologic evaluation of bile was performed. RESULTS: All 14 dogs survived until they were scheduled to be killed without clinical complication or evidence of jaundice. Patency was demonstrated at terminal cholangiography in 12 of 14 dogs and at explantation in 13 of 14 dogs. One Wallstent placed across the ampulla in a dog killed at 26 weeks became obstructed. In another dog, the presence of a cholelith in the cystic duct precluded filling of the common bile duct from the cholecystotomy. Only mild inflammatory changes were present in the bile ducts. CONCLUSION: The tantalum stent can be used safely and effectively in the common bile duct in normal dogs. Performance of a clinical trial in humans is supported finding of this study.

Ampulla of Vater↗

Experimental nonsurgical transcervical sterilization with a custom-designed platinum microcoil.

PURPOSE: Investigation of a technique for nonsurgical female sterilization. MATERIALS AND METHODS: A custom designed platinum microcoil with Dacron fibers was placed unilaterally into a fallopian tube and uterine horn of 10 rabbits after transcervical selective tubal catheterization with use of fluoroscopic guidance. The contralateral uterus and fallopian tube served as controls. After the rabbits were bred, pregnancy was determined by palpation and confirmed at autopsy. Postmortem histopathologic evaluation of uteri and fallopian tubes was performed. RESULTS: Nine of the 10 rabbits became pregnant. None of the animals had embryos on the microcoil side. Nine rabbits had a total of 45 embryos on the control side. One animal failed to become pregnant on either side. The microcoil remained in good position in all 10 rabbits. There was a microcoil-associated, mild inflammatory tissue response in the uteri and fallopian tubes. CONCLUSION: A platinum occlusion microcoil placed in a utero-tubal location has potential as a means for nonsurgical female sterilization.

Animals↗

Histologic development of the sheath that forms around long-term implanted central venous catheters.

BACKGROUND: Chronically implanted catheters often become covered with a thin, white adherent covering of tissue that has been referred to as a fibrin sheath. This tissue often interferes with catheter function. METHODS: To chronicle the development of this sheath, rats were implanted with silicone rubber central venous catheters. Five rats were euthanized at 3,7, and 60 days postimplantation so that gross necropsy and histology could be performed on the catheterized vessels. RESULTS: The coating that developed around the external portion of the catheter started as a dark red thrombus containing fibrin and progressed into vascularized, fibrous connective tissue. CONCLUSIONS: The translucent to white sheath that forms around chronically implanted catheters is not composed of fibrin and is therefore not likely to be dissolved by fibrinolytic agents such as urokinase, streptokinase, or tissue plasminogen activator.

Animals↗